150W Single Output with PFC Function
LPP-150 series
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Features:
- Universal AC input / Full range
- Built-in active PFC function, PF>0.96
- Protections: Short circuit / Overload / Over voltage
- Protections:Over temperature(option)
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at PFC:67KHz PWM:134KHz
- 3 years warranty
https://www.meanwell.com/Upload/PDF/PCB_EN.pdf
SPECIFICATION
MODEL | LPP-150-3.3 | LPP-150-5 | LPP-150-7.5 | LPP-150-12 | LPP-150-13.5 | LPP-150-15 | LPP-150-24 | LPP-150-27 | LPP-150-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 30A | 30A | 20A | 12.5A | 11.2A | 10A | 6.3A | 5.6A | 3.2A | |
CURRENT RANGE | 0 ~ 30A | 0 ~ 30A | 0 ~ 20A | 0 ~ 12.5A | 0 ~ 11.2A | 0 ~ 10A | 0 ~ 6.3A | 0 ~ 5.6A | 0 ~ 3.2A | |
RATED POWER | 99W | 150W | 150W | 150W | 151.2W | 150W | 151.2W | 151.2W | 153.6W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | 3.14 ~ 3.63V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 11.4 ~ 13.2V | 12.8 ~ 14.9V | 14.3 ~ 16.5V | 22.8 ~ 26.4V | 25.7 ~ 29.7V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 600ms, 30ms at full load | |||||||||
HOLD UP TIME (Typ.) | 30ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR | PF≧0.96/230VAC PF≧0.97/115VAC at full load | |||||||||
EFFICIENCY(Typ.) | 70% | 76% | 80% | 82% | 83% | 83% | 85% | 85% | 85% | |
AC CURRENT (Typ.) | 2.5A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 55A/230VAC | |||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.63 ~ 4.45V | 5.5 ~ 6.75V | 8.25 ~ 10.1V | 13.2 ~ 16.2V | 14.85 ~ 18.2V | 16.5~ 20.25V | 26.4 ~ 32.4V | 29.7 ~ 36.5V | 52.8 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60℃ with cooling FAN (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 2635.3K hrs min. Telcordia SR-332 (Bellcore) ; 292.7K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 222*75*41mm (L*W*H) | |||||||||
PACKING | 0.62Kg; 24pcs/16.6Kg/1.63CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com) 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
AC Input Connector (CN1) : JST B5P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | AC/L | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
2,4 | No Pin | ||
3 | AC/N | ||
5 | FG ![]() |
DC Output Connector (CN2) : JST B6P-VH*2 or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1~6 | -V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
7~12 | +V |
: Grounding Required
CN1: Pin 5 is safety ground
Block Diagram
Derating Curve
Output Derating VS Input Voltage
File Name: LPP-150-SPEC 2022-09-20
Documents / Resources
![]() |
MEAN WELL LPP-150 series Single Output with PFC Function [pdf] User Guide LPP-150-3.3, LPP-150-5, LPP-150-7.5, LPP-150-12, LPP-150-13.5, LPP-150-15, LPP-150-24, LPP-150-27, LPP-150-48, LPP-150 series Single Output with PFC Function, LPP-150, series Single Output with PFC Function, Output with PFC Function, PFC Function, Function |