Sinaccess

Synaccess SP-1005A SynLink Smart PDU

Synaccess SP-1005A-SynLink-Smart-PDU-img

Spesifikasi

  • UKURAN (HWD): Ukuran 9" x 1.75" x 5.8"
  • Jinis Plug: IEC-320 C20
  • INPUT VOLTAGE (S): 120V, 208V, 240V
  • MAX INPUT SAIKI: 20A
  • KAPASITAS DAYA:9 kVA - 3.8 kVA
  • FASE: 1
  • OUTLET VOLTAGES: 120V, 208V, 240V
  • OUTLET RECEPTACLES: NEMA 5-20(4), C13(4)
  • JUMLAH TOTAL OUTLET: 4
  • PENGUKURAN ENERGI / DAYA INPUT: Kilowatt jam (kWh), RMS Saiki (A), Frekuensi Garis (Hz), Voltage RMS (V), Daya Aktif (W), Daya Nyoto (VA), Faktor Daya
  • RANGE TEMPERATUR OPERASI: -5 nganti 60C
  • Asor relatif: 5-95% (non-kondensasi)
  • ELEVASI OPERASI MAKSIMUM: 0-10,000 ft. / 0 – 3,000 m
  • KAPASITAS SWITCHING NOMINAL (RES.LOAD): 3A 120VAC
  • MAKS SWITCHING ARUS: 3A (AC/DC)
  • MAX NGALIH VOLTAGE: 125VAC / 24DC
  • MAKS SWITCHING DAYA: 360VA
  • JUMLAH OUTPUT relay: 2

Deskripsi Produk

Gampang digunakake karo API HTTP sing didokumentasikake kanthi apik, perintah SSH/Telnet, lan API SNMP. Sembarang aplikasi pihak katelu bisa nggunakake API kanggo ngontrol lan mriksa pangukuran daya sing diklumpukake PDU. Examples kalebu ing dokumentasi pepek kanggo saben request API kanggo mbantu miwiti langsung.

Wis cukup stopkontak kanggo tambang cilik lan bisa ngirim nganti 20A listrik ing paket cilik. Nduwe omah sing kuat lan kabeh logam sing digawe kanggo urip ing kahanan sing paling angel. Kanthi presisi 0.1A, saben stopkontak individu bisa ngukur nganti 20A. Nalika peralatan mati; sampeyan bisa nyetel batesan tingkat rendah ing wacan daya tingkat stopkontak kanggo ngirim bebaya email.

Nalika kabeh gagal, pengawas jaringan sing dibangun nggawe manawa PDU tetep online. Ana kanggo nyegah muter truk larang, sensor konco saben relay njamin kinerja relay dipercaya ing lapangan.

Iku ngijini sampeyan kanggo ngatur otomatis lan kontrol (ON / OFF) dening dipakani nganti loro sinyal AC utawa DC. Kanthi pangguna-loropaken dibangun ing web antarmuka, sampeyan bisa gampang ngontrol relay. Sinyal nganti 125VAC / 24VDC / 3A bisa digunakake.

Apa sing ana ing Paket?

  • SP-1005A SynLink Smart PDU x 1
  • Kabel daya x 1

Pandhuan pangguna

Synaccess SP-1005A-SynLink-Smart-PDU-1

  1. port Ethernet 10/100 basis-t.
  2. Plug & play sensor port B (Sensor didol kanthi kapisah). Saiki ndhukung sensor suhu & kelembapan lingkungan. Luwih akeh sensor lan aktuator sing bakal teka.
  3. Pelabuhan kanggo expansion mangsa.
  4. Antarmuka push-tombol dinamis.
  5. Tombol reset sing ditutup. Urip maneh modul kontrol tanpa mengaruhi negara stopkontak.
  6. Port Serial USB (FTDI). Sambungake port iki menyang port USB PC kanggo ngontrol PDU nggunakake antarmuka baris printah.
  7. Port host USB kanggo lampiran USB 2.0 sing didhukung. (Dongle WiFi USB, dongle USB menyang Ethernet kanggo redundansi jaringan utawa Ethernet Passthrough, flash drive kanggo log lengkap (dhukungan firmware bakal teka), lan liya-liyane…).
  8. Port sensor A utawa port Serial (RS-232). Cisco pinout. Port iki bisa digunakake minangka server console. Sambungake piranti serial kanggo ngakses saka adoh nggunakake fitur console server.
  9. Tampilan LCD Warna Interaktif. Ngatur setelan jaringan, ngalih stopkontak, lan milih saka dhaptar screensaver informatif.
  10. LED status daya.

Pitakonan

Apa prabédan antarane PDU lan UPS?

Unit distribusi daya (PDU) nyedhiyakake sawetara piranti kanthi daya jaringan sing bisa dipercaya. Iku mung nyedhiyakake server, hardware jaringan, peralatan telekomunikasi, lan piranti liyane kanthi daya AC saka sumber daya sing ora bisa diganggu (UPS), generator, utawa sumber daya sarana. Iku ora gawé utawa kahanan daya.

Apa PDU lan cara kerjane?

PDU, uga dikenal minangka unit distribusi daya, nyedhiyakake daya jaringan sing terus-terusan menyang sawetara piranti. Tinimbang kahanan utawa ngasilake daya, PDU ngirimake daya AC saka sumber daya sarana, UPS, utawa generator menyang hardware jaringan, server, peralatan telekomunikasi, lan piranti penting liyane.

Apa PDU padha karo surge protector?

PDU ora duwe proteksi mundhak, dadi jelas.

Pira jinis PDU?

PDU rak kasedhiya ing papat macem-macem jinis:
PDU rak prasaja. PDU kanggo rak metered. Rak PDU diamati. Ngganti rak PDU.

Apa tampilan PDU?

Tambahan dikenal minangka "unit distribusi daya", PDU A unit distribusi daya standar wis akeh stopkontak lan meh podho Strip daya, nanging uga wis bagean electrical sing nggawe manawa saben stopkontak nampa jumlah witjaksono saka vol.tage. Dheweke asring digunakake ing pusat data kanggo ngirim daya sing bisa dipercaya menyang server sing disambung.

Bisa plug UPS menyang PDU?

PDUs dirancang kanggo nyambung menyang UPS. Padha lack pangayoman mundhak, asring mung breakers minangka ngalih lan konektor feed sing ora dirancang kanggo break ing mbukak. Ora mung bisa plug langsung menyang UPS, nanging iki dirancang karo plug UPS ing atine.

Apa sampeyan masang PDU?

Saben kabel input PDU nyambung menyang UPS kapisah, sumber daya saka sarana, utawa generator. PDU menehi sumber daya independen kanggo saben sumber daya nalika nyebarake daya kanggo peralatan karo sumber daya keluwih.

Kepiye cara ngawasi PDU?

Nggunakake antarmuka online PDU utawa Utilitas Konfigurasi IBM PDU, sampeyan bisa mriksa status daya saka piranti apa wae sing disambungake kanthi lokal utawa adoh. Kanggo nglacak panggunaan energi PDU lan klompok beban, sampeyan uga bisa nggunakake IBM Systems Director Active Energy Manager.

Suwene PDU sah?

PDU, sing duwe jendela kadaluwarsa telung taun, kudu nganyari sertifikasi.

Apa sing ana ing njero PDU?

PDU kabinet mandiri minangka unit mandiri sing duwe panel ngawasi daya, pemutus sirkuit utama, lan pemutus sirkuit individu. Bar bus internal kanggo netral lan lemah diwenehake dening kabinet. Panel ndhuwur lan ngisor karo bolongan prepunched ngidini kanggo mlebu kabel aman.

Apa PDU vs power strip?

Kanthi tambahan opsi kanggo jinis daya lan jumlah, jinis stopkontak / inlet, lan syarat safety liyane, PDU dhasar padha karo strip daya standar. Nanging, PDU uga kasedhiya karo fitur Intelligent (Intelligent PDU / iPDU), sing nduweni opsi kontrol & pemantauan luwih akeh liwat piranti sing dipasang.

Napa kita kudu PDU?

Daya listrik ing pusat data bisa diatur dening unit distribusi daya (PDU). Strip daya gedhe tanpa proteksi lonjakan yaiku PDU sing paling dhasar. Padha ora dimaksudaké kanggo ngawasi utawa akses remot; tinimbang, padha digawe kanggo kurban stopkontak listrik biasa kanggo peralatan pusat data.

Apa PDU perlu?

Unit distribusi daya (PDU) rack-mount utawa strip daya dibutuhake kanggo nyuplai daya menyang piranti ing meh kabeh rak peralatan Teknologi Informasi lan Komunikasi (ICT) sing digunakake kanggo ndhukung lan njaga panyimpenan, komputasi, utawa peralatan jaringan.

Apa PDU baterei?

PDU mung transfer listrik. Dheweke ora ngasilake. UPSs ateges baterei serep rak server. Padha kurban pangayoman lengkap marang masalah kualitas daya lan daya serep ing acara saka outage.

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *