Numeric UPS Line Interactive UPS 2000VA
INSTALASI & OPERASI
Inspeksi
Item ing ngisor iki ana ing njero kothak:
- Unit UPS
- Manual pangguna
Copot UPS saka sawijining paket lan priksa kerusakan sing bisa kedadeyan nalika ngirim. Yen ana karusakan sing ditemokake, bungkus maneh unit kasebut lan bali menyang papan sing dituku.
Nyambung menyang Daya Utilitas
Connect AC power cord to the utility power. Then, the UPS will start to charge inside battery. For the best result, charge the battery for 6 hours prior to initial use.
Plug in Peralatan
Plug your equipment into Battery Backup Outlets on the rear panel of the UPS.
CATETAN: Make sure that the UPS is powered on to protect all important devices from data loss during a power failure.
AWAS: NEVER connect a laser printer or scanner to the battery backup outlets of UPS. The equipment may draw significant power to overload the UPS.
TEMPAT & PENYIMPANAN
Panggonan
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Place the UPS away from other units at least 20 cm to avoid interference. For best performance, keep the indoor temperature between 0° C and 40° C.
Panyimpenan
All connected equipment should be turned off, then disconnected from the UPS to avoid battery drain. Unplug the UPS from the wall outlet. Then turn off the UPS for storage. Store the UPS unit covered and upright in environments where the ambient temperature is -20° C to 50° C with its battery fully charged.
OPERASI & FUNGSI
Operasi
Nguripake UPS
Kanggo nguripake unit UPS, pencet saklar daya entheng. Banjur, LED bakal murup.
Pateni UPS
To turn off the UPS unit, press the power switch again. Then, the LED will go off.
Fungsi Start Cold
When the UPS is off and there is no power utility, it’s still possible to cold-start the UPS unit to power the loads.
PANEL mburi
- stopkontak serep baterei
- MAC input
- Fuse/Circuit breaker (pilihan)
Indikator LED
2000VA
LED | Weker | Status UPS |
● Green | Mati | The mains are normal, and the UPS is operating normally. |
★Yellow | Swara saben 10 detik | Power failure occurs, and the UPS is in battery mode. |
★Yellow | Swara saben detik | Baterei sithik |
○ Green | Mati | UPS mati. |
● Red | terus-terusan
muni |
kesalahan UPS |
- LED on o LED Off * LED sumunar
- Check LED table base on the real product.
AWAS KESELAMATAN
SIMPAN INSTRUCTIONS IKI
Manual iki ngemot instruksi penting sing kudu ditindakake sajrone instalasi lan pangopènan UPS lan baterei.
- UPS iki nggunakake voltage sing bisa mbebayani. Aja nyoba mbongkar unit kasebut. Unit kasebut ora ngemot bagean sing bisa diganti pangguna. Mung personel layanan pabrik sing bisa ndandani.
- This pluggable type A equipment with battery already installed by the supplier is operator-installable and may be operated by laymen.
- Stopkontak stopkontak listrik sing nyedhiyakake UPS kudu dipasang ing cedhak UPS lan kudu gampang diakses.
- During the installation of this equipment, it should be ensured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
- Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in a shock hazard as well as violate local electrical codes.
- Yen ana kahanan darurat, pencet tombol "OFF" lan nyopot kabel listrik saka catu daya AC kanggo mateni UPS kanthi bener.
- Do not allow any liquids or any foreign objects to enter the UPS.
- Aja nyelehake omben-omben utawa prau sing ana cair liyane ing utawa cedhak unit kasebut.
- Unit iki dimaksudaké kanggo instalasi ing lingkungan kontrol (suhu-kontrol, area njero ruangan bebas saka rereged konduktif). Aja masang UPS ing panggonan sing ana banyu ngadeg utawa mlaku, utawa kelembapan sing berlebihan.
- Aja plug input UPS menyang output dhewe.
- Aja masang strip daya utawa surge suppressor menyang UPS.
- Aja masang barang sing ora ana gandhengane karo komputer, kayata peralatan medis, peralatan pendukung urip, oven gelombang mikro, utawa pembersih vakum menyang UPS.
SPESIFIKASI
MODEL | digital 2000 Plus |
KAPASITAS | 2000VA / 1200W |
Vol inputtage | 220-240 VAC |
Vol inputtage Range | 140-300 VAC |
Output Voltage Regulasi | ± 10 % (Mode Bat.) |
Wektu Transfer | Biasane 4-8 ms |
wangun gelombang | Gelombang Sinus Simulasi |
Jinis & Nomer Baterei | 12V-7Ah/9Ah x 2 |
Ngisi daya Wektu | 4-6 jam pulih nganti kapasitas 90% |
ukuran (WxDxH) mm | 130 x 320 x 182 |
Bobot Net (kg) | 10.6 |
Kelembapan | 0-90% RH @ 0-40°C non-kondensasi) |
Tingkat Noise | Kurang saka 40dB |
Spesifikasi bisa diganti tanpa kabar.
- Aja mbuwang baterei ing geni, amarga bisa njeblug.
- Batere bisa nyebabake risiko kejut listrik lan arus arus pendek sing dhuwur. Tindakan pancegahan ing ngisor iki kudu ditindakake nalika nggarap batere:
- Copot jam tangan, dering, utawa barang logam liyane saka tangan.
- Gunakake alat kanthi gagang terisolasi.
- Nganggo sarung tangan lan karet
- Aja nyelehake piranti utawa bagean logam ing ndhuwur baterei.
- Disconnect the charging source prior to connecting or disconnecting the battery terminal.
- Copot latar baterei sajrone instalasi lan pangopènan kanggo nyuda kemungkinan kejut.
- Do not dismantle the UPS system except the specialized technical personnel.
- Baterei internal voltagiku 12VDC. Baterei 6 sel sing disegel, asam timbal.
- Nglayani batere kudu dilakoni utawa diawasi dening personel sing ngerti babagan batere lan pancegahan sing dibutuhake. Jauhake personel sing ora sah saka batere.
- When replacing batteries, replace them with the same number and type of sealed lead-acid battery.
- Do not open or mutilate the battery or batteries. Releasing electrolytes is harmful to the skin and eyes. It may be toxic.
- Attention: hazardous through electric shock. Also, with the disconnection of this unit from the mains, hazardous voltage may still be accessible through the supply from the battery. The battery supply should therefore be disconnected in the plus and minus poles at the connectors of the battery when maintenance or service work inside the UPS is necessary.
- Kanggo nyuda risiko overheating UPS, aja nutupi ventilasi cooling UPS lan aja nganti mbukak unit menyang sinar srengenge langsung utawa nginstal unit ing cedhak piranti sing ngetokake panas kayata pemanas ruangan utawa tungku.
- Copot UPS sadurunge ngresiki lan aja nganggo deterjen cair utawa semprotan.
mecahaken masalah
Masalah | Kemungkinan Penyebab | Solusi |
Nothing is displayed on the LED panel. | UPS ora aktif. | Pencet saklar daya maneh kanggo nguripake UPS. |
Batere voltage kurang banget. | Ngisi daya baterei paling sethithik 6 jam. | |
Kesalahan baterei. | Ganti baterei. | |
UPS tansah ing mode baterei. | Kabel daya longgar. | Replug the power cord. |
UPS terus berbunyi bip. | Mangga dipriksa kode fault kanggo rincian. | Mangga dipriksa kode fault kanggo rincian. |
Wektu serep cendhak banget. | Batere voltage kurang banget. | Ngisi daya baterei paling sethithik 6 jam. |
Kakehan beban. | Copot sawetara beban sing ora perlu. Sadurunge nyambungake maneh peralatan, coba verifikasi manawa beban cocog karo kemampuan UPS sing kasebut ing spesifikasi. | |
Cacat baterei. | Ganti baterei. |
Yen ana kahanan ora normal sing ora kadhaptar ing ndhuwur, mangga nelpon kanggo layanan langsung.