MYRONL-logo

MYRONL RS485AD1 Multi-Parameter Monitor Controller

MYRONL-RS485AD1-Multi-Parameter-Monitor-Controller-produk

 

Spesifikasi:

  • Setengah duplex terisolasi
  • Tipe Konektor: RJ12
  • Label Konektor: RS-485
  • Kabeh nilai data dipisahake koma
  • Data diwakili ing karakter ASCII
  • Tingkat Serial Baud: 115200
  • Paritas Bit: Ora
  • Interval Wektu (ing detik): 30

Pandhuan Panggunaan Produk

Langkah Sambungan:

  1. Sambungake RJ12 menyang RJ12 kabel garis pinned langsung menyang adaptor RS-485.
  2. Sambungake adaptor RS-485 menyang piranti logging data (contone, komputer) nggunakake RS-485 menyang USB Industrial Converter.
  3. Sambungake lencana miturut sambungan sing kasedhiyaamples, njamin sinyal sing tepat lan sambungan lemah.
  4. Yen nggunakake terminasi, singkat TERM 1 kanggo TERM 2 ing unit pungkasan lan aplikasi terminasi kanggo loro ujung kabel.

Ngaktifake / Mateni Pemutusan Garis:

Kanggo ngaktifake / mateni mandap baris ing adaptor RS-485, nyetel Line Termination Jumper kanggo salah siji ON (Aktif) utawa OFF (Disabled) posisi yen perlu.

FAQ

  • P: Apa aku kudu nggawe modifikasi program kanggo streaming data ing model 900 Series 900M-3C?
    • A: Ora, streaming otomatis ing model 900 Series 900M-3C; modifikasi program ora perlu.
  • P: Apa mandap dibutuhake kanggo dawa kabel?
    • A: Mandap biasane ora dibutuhake kanggo dawa kabel, nanging yen digunakake, mesthekake mandap ditrapake kanggo loro ends kabel.

Pandhuan kanggo Streaming Output Serial Nggunakake Port Komunikasi RS-485 

Port komunikasi RS-485 ing Seri 900 ngidini logging data tanggal/wektu, lokasi, lan informasi pangukuran ing wangun data ASCII serial. Iku data siji-arah streaming saka 900 Series menyang piranti logging data kayata komputer.

modifikasi Programming ora perlu ing model 900 Series 900M-3C; streaming otomatis.

Spesifikasi

  • Output Seri RS-485
  • Terisolasi
  • Setengah duplex
  • Tipe Konektor: RJ12
  • Label Konektor: RS-485
  • Kabeh nilai data dipisahake koma
  • Data diwakili ing karakter ASCII
  • Tingkat Serial Baud: 115200
  • Paritas Bit: Ora
  • Interval Wektu (ing detik): 30

Sambungan

Sambungan Examples

Example #1 nggunakake peralatan sing disedhiyakake pelanggan: 

MYRONL-RS485AD1-Multi-Parameter-Monitor-Controller-anjir (1)

Kanggo ngaktifake pemutus kabel ing unit pungkasan, singkat TERM 1 nganti TERM 2.

CATETAN: Yen sampeyan nggunakake terminations, padha kudu Applied kanggo loro ends kabel

Example #2 nggunakake Myron L® Company RS-485 Adaptor (Part # RS485AD1): 

MYRONL-RS485AD1-Multi-Parameter-Monitor-Controller-anjir (2)

Aktifake/Pateni Pemutusan Garis ing Adaptor RS-485:

  • Resistor Terminating Kab: 120
  • Mandap biasane ora dibutuhake kanggo dawa kabel <100'.
  • Yen sampeyan nggunakake terminasi, kudu ditrapake ing ujung kabel (RS485AD1 lan kabel sing disedhiyakake pangguna.
  • Konverter RS-485 kanggo USB).
  • Tindakake pedoman industri kanggo aplikasi sampeyan kanggo nemtokake manawa dihentikan baris dibutuhake.
  • Gunakake mung kabel pasangan bengkong RS-485 (misample: Belden 3105A).
  • Sambungake telung kabel RS-485 menyang port A utawa port B kaya sing dituduhake ing ndhuwur.
  • Kanggo bagan Data Output Serial Streaming RS-485, dokumen iki.

RS-485 Streaming Data Output Serial miturut Urutan Pangiriman (data diwatesi koma): 

Label Data Exampsaka Data Katrangan Data Detail Data
Tanggal lan Wektu 10/29/21 14:15:15 Nilai Tanggal lan Wektu saka 900
Jeneng Panggonan MEJA TC Jeneng Lokasi sing disimpen ing 900
COND/RES 1 Nilai 990.719 Nilai Pangukuran Utama, Sensor: Cond/Res1 Yen ora ana sensor, banjur kacarita maca bakal

-3000.00 (setara karo N/A) 1

KOND/RES 1 Unit ppm Unit Pengukuran Utama, Sensor: Cond/Res1
KOND/RES 1 Temp.

Nilai

23.174 Nilai Pangukuran Sekunder (Suhu),

Sensor: Cond/Res1

Yen ora ana sensor, banjur kacarita maca bakal

-1.000 (setara karo N/A) 1

KOND/RES 1 Temp. Unit C Unit Pengukuran Sekunder (Suhu), Sensor: Cond/Res1
COND/RES 2 Nilai 164.008 Nilai Pangukuran Utama, Sensor: Cond/Res2 Yen ora ana sensor, banjur kacarita maca bakal

-3000.00 (setara karo N/A) 1

KOND/RES 2 Unit ppm Unit Pengukuran Utama, Sensor: Cond/Res2
KOND/RES 2 Temp.

Nilai

3.827 Nilai Pangukuran Sekunder (Suhu), Sensor: Cond/Res2 Yen ora ana sensor, banjur kacarita maca bakal

-1.000 (setara karo N/A) 1

KOND/RES 2 Temp. Unit C Unit Pengukuran Sekunder (Suhu), Sensor: Cond/Res2
Nilai pH/ORP MLC 6.934 Nilai Pangukuran Utama, Sensor: MLC pH/ORP Yen ora ana sensor, banjur kacarita maca bakal

-3000.00 (setara karo N/A) 1

MLC pH/ORP Unit Unit Pengukuran Utama, Sensor: MLC pH/ORP Unit pH: Kosong

Unit ORP: mV

MLC pH/ORP Temp. Nilai 4.199 Nilai Pangukuran Sekunder (Suhu), Sensor: MLC pH/ORP Yen ora ana sensor, banjur kacarita maca bakal

-1.000 (setara karo N/A) 1

MLC pH/ORP Temp. Unit C Unit Pengukuran Sekunder (Suhu), Sensor: MLC pH/ORP
mV IN Nilai 6.993 Nilai Pangukuran Utama, Sensor: mV IN Yen ora ana sensor, banjur kacarita maca bakal

-3000.00 (setara karo N/A)1, 2

mV ing Unit Unit Pengukuran Utama, Sensor: mV IN Unit pH: Kosong

Unit ORP: mV

mV IN Temp. Nilai 96.197 Nilai Pangukuran Sekunder (Suhu), Sensor: mV IN Yen ora ana sensor, banjur kacarita maca bakal

-1.000 (setara karo N/A) 1, 2

mV IN Temp. Unit C Unit Pengukuran Sekunder (Suhu), Sensor: mV IN
Suhu RTD Nilai 96.195 Nilai Pangukuran Utama, Sensor: RTD Yen ora ana sensor, banjur kacarita maca bakal

-3000.00 (setara karo N/A)

Suhu RTD Unit C Unit Pengukuran Utama, Sensor: RTD
N/A -1.000 Ora Digunakake Ora Digunakake
N/A C Ora Digunakake Ora Digunakake
4-20 mA IN Nilai 0.004 Nilai Pangukuran Utama, Sensor: 4-20mA In
4-20 mA IN Unit mA Unit Pengukuran Utama, Sensor: 4-20mA In
N/A -1.000 Ora Digunakake Ora Digunakake
N/A Ora Digunakake Ora Digunakake
Nilai Aliran / Pulse 0.000 Nilai Pangukuran Utama, Sensor: Flo/Pulse
Unit Aliran / Pulsa gpm Unit Pengukuran Utama, Sensor: Flo/Pulse
Nilai Sekunder Aliran / Pulsa 0.000 Nilai Pangukuran Sekunder, Sensor: Flo/Pulse Nilai Aliran utawa Volume

-1.000 yen pangukuran utami Pulse

Unit Sekunder Aliran/Pulse Gal Unit Pengukuran Sekunder, Sensor: Flo/Pulse Unit Aliran utawa Volume

Kosong yen pangukuran utama yaiku Pulse

% Nilai Tolak 83.446 Nilai Pangukuran Utama, Sensor: % Penolakan N/A yen % Penolakan dipateni ing 900
% Unit Tolak % Unit Pengukuran Utama, Sensor: % Penolakan N/A yen % Penolakan dipateni ing 900
N/A -1.000 Ora Digunakake N/A
N/A C Ora Digunakake N/A

1Wacan "-3000" kanggo pangukuran utami utawa "-1.000" kanggo pangukuran sekunder minangka indikasi yen ora ana sensor sing dideteksi, utawa ana kesalahan ing setelan.

2 Yen jinis pangukuran saluran input mV IN disetel menyang pH (kanthi kompensasi suhu), pangukuran sekunder (suhu) bakal padha karo saluran input RTD. Yen ora ana sensor suhu sing disambungake menyang input RTD, pangukuran mV IN primer lan sekunder bakal nuduhake yen ora ana sensor sing dideteksi.

Dibangun ing Trust. Didegaké ing taun 1957, Myron L Company minangka salah sawijining pabrikan instrumen kualitas banyu sing misuwur ing donya. Amarga komitmen kanggo nambah produk, owah-owahan ing desain lan spesifikasi bisa uga. Sampeyan duwe jaminan manawa owah-owahan bakal dipandu dening kita filosofi produk: akurasi, linuwih, lan prasaja.

MYRONL-RS485AD1-Multi-Parameter-Monitor-Controller-anjir (3)

Dokumen / Sumber Daya

MYRONL RS485AD1 Multi Parameter Monitor Controller [pdf] Instruksi Manual
RS485AD1 Multi Parameter Monitor Controller, RS485AD1, Multi Parameter Monitor Controller, Parameter Monitor Controller, Monitor Controller, Controller

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *