JBC TCP Thermocouple Pointer

JBC-CP-Thermocouple-Pointer-PRODUCT

INSTRUKSI PENGGUNAAN PRODUK

Manual iki cocog karo referensi ing ngisor iki:
TCP-A

Daftar Packing
Item ing ngisor iki kalebu:JBC-CP-Thermocouple-Pointer-FIG (2)

Fitur

TCP Thermocouple Pointer is designed to monitor the surface temperature of the PCB or its components with high precision positioning. It works on any type of material and can measure temperatures up t300 °C / 572 °F with an accuracy of ±10 °C / 19 °F. Its design allows for quick and accurate placement of high-density printed circuit boards, reducing setup time, even at high temperatures.TCP features a K-type signal output, so the monitoring device to which it is connected must have a K-type compatible connector. For compatibility information with JBC devices, visit the product’s page at www.jbctools.com. For more information on compatibility with external devices, contact JBC Technical Support. The sensor is completely isolated (electrically) from the external parts of the product. TCP is ESD safe with no extra connections, as long as it sits on any kind of ESD safe surface, e.g., JBC ESD safe table mats, a ground-wired metal surface, etc. It is also possible to ground the product from any of its metal surfaces.

TCP is not intended for use in fluids such as flux or molten tin, nor is it designed for the measurement of hot air. When connecting TCP to a monitoring device (K-type compatible connector required), always use the thermocouple extension cable supplied with this product. The temperature measurement can be affected by air currents. Keep this in mind  when using hot air tools (JTT or NH) or fume extractors (FAE1, FAE2)JBC-CP-Thermocouple-Pointer-FIG (3)

Papan Kerja ExampleJBC-CP-Thermocouple-Pointer-FIG (4)

Cara Gunakake

  1. Check that the sensor has the cup and a portion of the conductive pad attached to the tip. If it has come loose, see the next section, Replacing the Conductive Pad Set.
  2. Connect the thermocouple pointer to a monitoring device (K-type compatible connector required) using the supplied thermocouple extension cable.
  3. Thanks to its magnetic base, TCP can be placed and stabilized onto magnetic surfaces. If there is no magnetic surface available, see the “Anchor Assembly” section.
    • Avoid placing the base of TCP in direct contact with a heat source.
  4. Take the pointer from its base and place it completely vertical on the exact spot you want to measure.
  5. Important: Press the pointer lightly against the measurement spot to ensure that theconductive pad makes contact around the entire perimeter.JBC-CP-Thermocouple-Pointer-FIG (5)

Replacing the Conductive Pad 

  1. Hold the assembled cup with one hand and remove any residue of the conductive pad by gently moving the pointer inside it. Then, detach the cup from the sensor. If necessary, replace the cup with a new one.
  2. Unwrap both sides of the conductive pad. Place it on a flat surface and place the cup ontop of the conductive pad.JBC-CP-Thermocouple-Pointer-FIG (6)
  3. Then, exert pressure down to crop off a portion of the conductive pad, which remains embedded in the cup.JBC-CP-Thermocouple-Pointer-FIG (7)
  4. . Insert the sensor through the top opening of the cup until it reaches the pad. Lightly press down the sensor a couple of times so that it is inserted into the pad, but without piercing it completelyJBC-CP-Thermocouple-Pointer-FIG (8)
    • penting: Do not pierce the conductive pad completely. Leave a thin layer of conductive material between the tip of the sensor and the bottom surface of the pad.JBC-CP-Thermocouple-Pointer-FIG (9)
  5. Carefully lift the sensor with the cup and the pad embedded inside.JBC-CP-Thermocouple-Pointer-FIG (10)

Anchor Assembly
If there is no magnetic surface available to place the base onto, the supplied anchor (magnetic) can be placed on a JBC support, allowing TCP to be fixed onto it. After its use, the base can be more easilyseparated from the anchor/magnetic surface by tilting it apart.

To assemble the magnetic anchor onto the guides of the support:

  1. Unscrew the anchor using a 2.5 Allen key (DIN911).
  2. Cocog karo clamp of the anchor into one of the guides on the support from below (1).
  3. Position the disc on the guide, aligning its center with that of the lower piece.
  4. Fix the anchor by screwing the two pieces together from the top (2).
  5. Place the base of the thermocouple pointer on the anchor.JBC-CP-Thermocouple-Pointer-FIG (11)

Pangopènan

  • Sadurunge nindakake pangopènan utawa panyimpenan, tansah ngidini peralatan dadi adhem.
  • Priksa kanthi periodik manawa sensor kasebut resik.
  • Gunakake iklanamp kain nalika ngresiki. Alkohol mung bisa digunakake kanggo ngresiki bagean logam.
  • Ganti bagean sing rusak utawa rusak. Gunakake spare parts JBC asli mung.
  • Ndandani mung kudu ditindakake dening layanan teknis sing sah JBC.

Spesifikasi

TCP

Thermocouple Pointer
Ref.: TCP-A

  • Output: Type K
  • Measurable Temperature Range: 25-300 °C / 77-572 °F
  • Total Bobot Net: 470 g / 1.04 lb
  • Ukuran Paket / Berat: 280 x 280 x 164 mm / 730 g (L x W x H) 11.02 x 11.02 x 6.46 in / 1.61 lb
  • Selaras karo standar CE.
  • ESD aman.

Garansi
Garansi 2 taun JBC nutupi peralatan iki marang kabeh cacat manufaktur, kalebu panggantos komponen lan tenaga kerja sing rusak. Garansi ora nutupi nyandhang utawa nyalahi panggunaan produk. Supaya babar pisan bener, peralatan kudu bali, postage mbayar, kanggo bakul ngendi iku dituku.

JBC-CP-Thermocouple-Pointer-FIG (12)Produk iki ora kudu dibuwang ing tong sampah. Sesuai karo arahan Eropa 2012/19/EU, peralatan elektronik ing pungkasan umure kudu diklumpukake lan bali menyang fasilitas daur ulang sing sah.

www.jbctools.com

FAQ

Q: Can TCP be used in fluids?

A: No, TCP is not intended for use in fluids.

Q: How should I store TCP when not in use?

A: Store TCP on an ESD safe surface to maintain its integrity.

Q: Can TCP measure hot air?

A: TCP is not designed for the measurement of hot air.