Ethernet-SPI/DMX Piksel cahya controller
Manual pangguna
(Waca manual iki kanthi teliti sadurunge digunakake)
Dianyari Wektu: 2019.11.1
Pambuka Brief
Controller cahya piksel Ethernet-SPI / DMX iki darmabakti kanggo ngowahi sinyal Ethernet dadi sinyal piksel SPI, sing dirancang kanggo proyek gedhe kanthi cahya piksel kanthi kapadhetan dhuwur, kayata lampu panel matriks, lan kontur konstruksi l.amp, etc. Kejabi Ngonversi protokol kontrol basis Ethernet menyang macem-macem LED nyopir sinyal IC, uga output DMX512 sinyal ing wektu sing padha, trep kanggo sambungan saka macem-macem jinis led l.amp, lan kanggo entuk kontrol terpadu kabeh jinis dipimpin lamp ing project padha.
Spesifikasi
Model | 204 | 216 |
Kerja Voltage | DC5-DC24V | DC5-DC24V |
Output Saiki | 7A X 4CH (Built-in 7. 5A sekring) | 3A X 16CH (Built-in 5A sekring) |
protokol kontrol Ethernet input | ArtNet | ArtNet |
IC Kontrol Output | 2811/8904/6812/2904/1814/1914/5603/9812/APA102/2812/9813/3001/8806/6803/2801 | |
Kontrol Piksel | RGB: 680 piksel x 4CH RGBW: 512 piksel x 4CH |
RGB: 340 piksel x 16CH RGBW: 256 piksel x 16CH |
Output DMX512 | Siji port (1X512 Saluran) | Loro port (2X512 Saluran) |
Temp Kerja | -20-55°C | -20-55°C |
Dimensi produk | L166xW111.5xH31 (mm) | L260xW146.5xH40.5 (mm) |
Timbangan (GW) | 510g | 1100g |
Fitur dhasar
- Kanthi tampilan LCD lan dibangun ing WEB Antarmuka setelan SERVER, operasi gampang.
- Dhukungan Ethernet DMX protokol ArtNet bisa ditambahi kanggo protokol liyane.
- Output sinyal multi SPI (TTL).
- Output DMX512 sinyal ing wektu sing padha, trep kanggo sambungan saka macem-macem jinis led lamps.
- Ndhukung macem-macem LED driving IC, lan kontrol fleksibel.
- Ndhukung upgrade firmware online.
- Nganggo desain plug-in DIP kanggo bagean sing gampang dipakai, Pangguna bisa ndandani karusakan sing disebabake kabel sing salah utawa sirkuit cendhak.
- Mode tes sing dibangun, nggunakake antarmuka jaringan kanthi lampu indikator, status kerja jelas yen sekilas.
bebaya safety
- Aja nginstal controller iki ing kilat, Magnetik kuat, lan dhuwur-voltage lapangan.
- Kanggo nyuda resiko karusakan komponen lan geni disebabake short circuit, priksa manawa sambungan sing bener.
- Tansah priksa manawa unit iki dipasang ing area sing ngidini ventilasi sing tepat kanggo njamin suhu sing pas.
- Priksa manawa voltage lan adaptor daya cocog karo controller.
- Aja nyambungake kabel kanthi daya urip, priksa manawa sambungan sing bener lan ora ana sirkuit cendhak sing dicenthang karo instrumen sadurunge diuripake.
- Mangga aja mbukak tutup controller lan operate yen ana masalah. Manual mung cocok kanggo model iki; nganyari apa wae bisa diganti tanpa kabar sadurunge.
ukuran

Instruksi Operasi
204 216 Instruksi antarmuka lan port:
Instruksi kabel port output SPI:
Kabar: Pengontrol kudu nyambung karo rong sumber daya. Sumber daya 2st ndhukung SPI 1-8, sumber daya 1 ndhukung SPI 9-16, (Loro input daya bisa nuduhake sumber daya unit sing padha nalika daya cukup).
Kanggo output sinyal kontrol LPD6803/LPD8806/P9813/WS2801, mbutuhake paling ora telung baris:
DATA | 6803/8806/9813/2801 DATA |
CLK | 6803/8806/9813/2801 CLK |
GND | GND, nyambung karo chip GND |
Kanggo output sinyal kontrol WS2811 / TLS3001 / TM1814 / SK6812, mbutuhake paling ora rong baris:
DATA | DATA WS2811/ TLS3001 |
GND | GND, nyambung karo chip GND |
Sambungake Lamps sumber positif kanggo + saka bandar output SPI.
1. Katrangan Kunci
Tombol | Fungsi Short Press | Fungsi Long Press |
MODE | Ngalih jinis parameter setelan | Ketik mode metu test |
SETUP | Ketik lan ngalih persiyapan | |
+ | Tambah nilai set saiki | Nambah nilai set saiki kanthi cepet |
– | Ngurangi nilai set saiki | Ngurangi nilai set saiki kanthi cepet |
Ketik | Konfirmasi lan ketik nilai set sabanjure |
2. Instruksi operasi lan setelan
Ethernet-SPI/DMX piksel cahya controller karo loro model digunakake.
Mungguh: mode kerja normal lan mode tes.
(1) Mode kerja normal
mode normal adhedhasar Ethernet nransfer protokol Artnet menyang sinyal kontrol kang bisa ditampa dening macem-macem piksel lamps; Nyambung lamps, plugging kabel jaringan, sawise mriksa, daya urip. Kontroler bakal mlebu menyang deteksi jaringan.
Ora bisa
OPERASI…
Sawise ndeteksi tanpa masalah, pengontrol bakal mlebu menyang mode kerja normal lan nuduhake alamat IP, alamat IP duwe alokasi statis lan dinamis. STAT kanggo alokasi statis, DHCP kanggo alokasi dinamis, alamat IP standar controller statis.
ALAMAT IP - STAT
192.168.0.50
Kontroler iki uga dilengkapi fungsi kunci tombol, ora ana operasi sawise 30 detik, sistem mlebu ing negara kunci, banjur ditampilake LCD.
TEKAN terus M
TOMBOL kanggo mbukak kunci
Pencet dawa "MODE" kanggo mbukak kunci, ora dikunci sadurunge operasi sabanjure.
(2) Setelan Parameter
Ing mode kerja normal, pencet "MODE" kanggo ngalih jinis setelan parameter, "SETUP" kanggo ngetik persiyapan, banjur pencet "ENTER" kanggo bali menyang tingkat sadurunge.
NO. | Setelan | tampilan LCD | Nilai |
1 | Persiyapan sistem | 1 SETUP SISTEM | |
Pilihan statis lan dinamis IP | IP STATIS 192.168.0.50 |
Dynamic efault YA: IP NO: Statis IP(D) | |
Alamat IP | DHCP-YA PENET OK kanggo nyimpen |
Alamat IP statis (Default): 192.168.0.50 | |
Topeng Subnet | IP STATIS 192.168.0.50 |
(Default): 255.255.255.0 | |
Jinis IC | SUBNET MASK 255.255.255.0 |
“2811(Default)”“8904”“6812”“2904”“1814”“1914” “5603”“9812”“APA102”“2812”“9813”“3001” "8806" "6803" "2801" |
|
Urutan RGB | PROTOKOL PIXEL 2811 |
"RGB(Default)" "RBG" "GRB" "GBR" "BRG" "BGR" "RGBW" "RGWB" "RBGW" "RBWG" "RWGB" "RWBG" "GRBW" "GRWB" "GBRW" "GBWR" "GWRB" "GWBR" "BRGW" "BRWG" "BGRW" "BGWR" "BWRG" "BWGR" "WRGB" "WRBG" "WGRB" "WGBR" "WBRG" "WBGR" |
|
Konfigurasi sinyal | LED RGB SEQ RGB |
Mung ndhukung ArtNet saiki | |
Pilihan wektu dormansi latar mburi LCD | KONFIG SINYAL ArtNet |
"Tansah Aktifake" "1 MENIT" "5 MENIT" "10 MENIT" |
|
2 | Setelan saluran 1 | Lampu mburi LCD SELALU MATI |
204: OUT1-4 SETUP 216: OUT1-16 SETUP |
Persiyapan Universe | 2 OUT1 SETUP. | Range setelan Universe: 1-256 |
Saluran DMX | OUT1 SALURAN MULAI:512 | Range saluran DMX: 1-512 Nilai standar: 1 |
|
Piksel | OUT1 NUM PIKSEL: 680 | 204: Rentang piksel: 0-680 Nilai standar: 680 216: Rentang piksel: 0-340 Nilai standar: 340 |
|
Null piksel | OUT1 NULL PIKSEL: 680 | 204: Rentang piksel null: 0-680 Nilai standar: 0
216: Rentang piksel null: 0-340 Nilai standar: 0 |
|
Piksel zigzag | OUT1 ZIG ZAG: 680 | 204: Zig zag kisaran piksel: 0-680 Nilai standar: 0 216: Rentang piksel Zig zag: 0-340 Nilai standar: 0 |
|
Kontrol mbalikke | OUT1 DIBALI: YA | YA: Kontrol mbalikke NO (Default): Ora kontrol mbalikke | |
3 | Setelan saluran 2 | 3. OUT2 SETUP | Padha karo saluran 1 |
4 | Setelan saluran 3 | 4. OUT3 SETUP | Padha karo saluran 1 |
5 | Setelan saluran 4 | 5. OUT4 SETUP | Padha karo saluran 1 |
6 | DMX512 persiyapan saluran | 6. DMX512 OUTPUT | 204: Siji saluran DMX512 216: Loro saluran DMX512 |
DMX512 pilihan output | DMX512 OUTPUT YA | YES (Default): Output NO: Ora output | |
DMX512 alam semesta persiyapan | DMX512 SEMESTA: 255 |
DMX512 Domain kisaran setelan: 1-256 | |
7 | Muat gawan | 7. MUNGKIN DEFAULT | |
Konfirmasi kanggo mbukak standar | LOAD DEFAULT KOWE YAKIN? | ||
8 | Babagan | 8. Babagan | |
Model | Ethernet-SPI4 ID: 04000012 |
Tipe IC Kontrol:
Tipe IC | IC sing kompatibel | Jinis |
2811 | TM1803、TM1804、TM1809、TM1812、UCS1903、UCS1909、UCS1912 UCS2903、UCS2909、UCS2912、WS2811、WS2812B、SM16703P 、GS8206 etc |
RGB |
2812 | TM1803、TM1804、TM1809、TM1812、UCS1903、UCS1909、UCS1912 UCS2903、UCS2909、UCS2912、WS2811、WS2812B、SM16703P 、GS8206 etc |
|
2801 | WS2801, WS2803 lsp | |
6803 | LPD6803、LPD1101、D705、UCS6909、UCS6912 etc | |
3001 | TLS3001, TLS3002 etc | |
8806 | LPD8803 LPD8806 LPD8809 LPD8812 etc | |
9813 | p9813 lsp | |
APA102 | APA 102 SK9822 etc | |
1914 | TM1914 etc | |
9812 | UCS9812 etc | |
5603 | UCS5603 etc | |
8904 | UCS8904 etc | RGBW |
1814 | TM1814 etc | |
2904 | SK6812RGBW, UCS2904B, P9412 etc | |
6812 | SK6812RGBW, UCS2904B, P9412 etc |
(3) Mode tes
Pencet dawa "MODE" kanggo ngetik mode test, pencet maneh kanggo metu, sawise ngetik mode test, pencet "+" "-" kanggo ngalih mode lan "SETUP" kanggo nyetel parameter saka mode saiki. Sawise ngetik mode test, LCD bakal nuduhake tips operasi, kaya ing ngisor iki:
TEKAN terus M FOR MODE NORMAL |
TEKAN "+" UTAWA "-" PILIH MODE |
NO. | Dibangun ing urutan | NO. | Dibangun ing urutan |
1 | Warna Solid: Black (Off) | 13 | Biru nguber karo jejak |
2 | Warna Solid: Red | 14 | Rainbow chase - 7 werna |
3 | Warna Solid: Green | 15 | Ijo ngoyak Abang, ngoyak Ireng |
4 | Warna Solid: Biru | 16 | Abang ngoyak Ijo, ngoyak Ireng |
5 | Warna Solid: Kuning | 17 | Abang nguber Putih, nguber Biru |
6 | Warna Solid: Ungu | 18 | Oranye nguber Ungu, nguber Ireng |
7 | Warna Solid: CYAN | 19 | Ungu ngoyak Oranye, ngoyak Ireng |
8 | Warna Solid: Putih | 20 | Kelip-kelip acak: Putih ing latar mburi abang |
9 | RGB GANTI | 21 | Kelip-kelip acak: Putih ing latar mburi biru |
10 | GANTI WARNA lengkap | 22 | Kelip-kelip acak: Putih ing latar mburi ijo |
11 | Red chase karo trail | 23 | Kelip-kelip acak: Putih liwat ungu, latar mburi |
12 | Green nguber karo Trail | 24 | Kelip-kelip acak: Putih ing latar mburi oranye |
3. WEB setelan, Nganyarke firmware online.
Kajaba iku, kanggo nyetel paramèter kanthi tombol, sampeyan uga bisa nyetel liwat Web browser komputer. Setelan parameter antarane loro padha.
WEB instruksi operasi:
Bukak ing web browser komputer, sing ana ing LAN sing padha karo pengontrol, ketik alamat IP (kayata IP standar: 192.168.0.50), banjur pencet "Enter" kanggo nelusuri controller sing dibangun ing. websitus, kaya ing ngisor iki:
Ketik sandhi standar: 12345, Klik kanggo ngetik kaca setelan parameter.
Pangguna bisa nyetel parameter lan nganyarke perangkat kukuh ing websitus.
Nganyarke firmware online:
Kanggo nemokake kolom "Update Firmware" ing websitus (kaya ing ngisor iki)
Banjur klik , kanggo ngetik nganyari perangkat kukuh kaca (kaya ing ngisor iki), klik,
banjur pilih BIN file sampeyan kudu nganyarke, banjur klik
ketik menyang kaca nganyari perangkat kukuh, Sawise upgrade, ing websitus bakal kanthi otomatis bali menyang layar login. milih file Nganyari
Diagram Konjungsi
Sawise-Sales
Wiwit dina sampeyan tuku produk kita sajrone 3 taun, yen digunakake kanthi bener miturut pandhuane, lan masalah kualitas kedadeyan, kita nyedhiyakake layanan perbaikan utawa panggantos gratis kajaba ing kasus ing ngisor iki:
- Cacat apa wae sing disebabake dening operasi sing salah.
- Sembarang karusakan sing disebabake dening sumber daya sing ora cocog utawa vol abnormaltage.
- Sembarang karusakan sing disebabake dening mbusak, pangopènan, modifikasi sirkuit sing ora sah, sambungan sing salah, lan ngganti chip.
- Kerusakan apa wae amarga transportasi, pecah, utawa banjir sawise tuku.
- Sembarang karusakan sing disebabake dening lindhu, geni, banjir, sambaran petir, lan liya-liyane force majeure bencana alam.
- Sembarang karusakan sing disebabake dening kelalaian, panyimpenan sing ora cocog ing lingkungan suhu lan kelembapan sing dhuwur utawa cedhak karo bahan kimia sing mbebayani.
Dokumen / Sumber Daya
![]() |
iPixel LED SPI-DMX Ethernet Pixel Light Controller [pdf] Manual pangguna SPI-DMX, Controller cahya piksel Ethernet, Controller cahya piksel, Controller cahya, SPI-DMX, Contr |