104-COM-8S, 104-COM-4S 8/4 Port Papan Komunikasi Serial

Informasi produk

Spesifikasi

  • Jeneng produk: ACCES I/O 104-COM-8S
  • Tipe: Wolung utawa Four-Port RS-422/485 PC/104 Serial
    Papan Komunikasi
  • Model Kasedhiya: 104-COM-8S lan 104-COM-4S
  • Produsen: ACCES I/O Products, Inc.
  • Alamat: 10623 Roselle Street, San Diego, CA 92121
  • Kontak: 858-550-9559, contactus@accesio.com
  • Websitus: www.accesio.com

Pandhuan Panggunaan Produk

Pènget

Tansah nyambung lan pedhot kabel Field Panjenengan
DAYA KOMPUTER MATI. Tansah mateni daya komputer sadurunge
NGINSTAL PAPAN. Sambungake lan DISCONNECTING KABEL, UTAWA
NGINSTAL PAPAN ING SISTEM KARO KOMPUTER UTAWA DAYA FIELD ON
Bisa njalari ngrusak papan I/O lan bakal ngilangi kabeh JAMINAN,
TERSIRAT UTAWA DIBUKA.

Garansi

Sadurunge dikirim, peralatan ACCES dipriksa kanthi teliti lan
dites kanggo specifications ditrapake. Nanging, kudu peralatan
Gagal dumadi, ACCES njamin pelanggan sing layanan cepet lan
dhukungan bakal kasedhiya.

Sarat lan Ketentuan

Telung taun pisanan: Unit bali / bagean bakal
didandani lan / utawa diganti ing pilihan ACCES tanpa biaya kanggo pegawe
utawa bagean ora tilar dening babar pisan. Garansi diwiwiti kanthi
pangiriman peralatan.

Taun-taun sabanjure: Kabeh peralatan sampeyan
urip, ACCES stands siyap kanggo nyedhiyani ing situs utawa ing-tanduran layanan
ing tarif cukup padha karo manufaktur liyane ing
industri.

Peralatan Ora Diprodhuksi dening ACCES: prabotan
kasedhiya nanging ora diprodhuksi dening ACCES dijamin lan bakal
didandani miturut syarat lan katemtuan masing-masing
garansi pabrikan peralatan.

FAQ

P: Apa sing kudu ditindakake yen peralatanku gagal?

A: Hubungi ACCES kanggo layanan cepet lan dhukungan. Rujuk menyang
syarat babar pisan kanggo rincian ing ndandani utawa panggantos.

P: Kepiye carane bisa njamin keamanan papan I / O sajrone
instalasi?

A: Tansah nyambung lan medhot sambungan kabel lapangan karo komputer
mateni daya. Pateni daya komputer sadurunge nginstal papan kanggo
nyegah karusakan.

“`

ACCES I/O 104-COM-8S Entuk Penawaran
10623 Roselle Street, San Diego, CA 92121 y 858-550-9559 y Fax 858-550-7322 contactus@accesio.com y www.accesio.com
WONG- UTAWA PAPAT-PORT RS-422/485 PC/104 MODEL PAPAN KOMUNIKASI SERIAL 104-COM-8S LAN 104-COM-4S
MANUAL PENGGUNA

www.assured-systems.com | sales@assured-systems.com

File: M104-COM-8S.A1k
Kaca 1/28

ACCES I/O 104-COM-8S Entuk Penawaran

Kabar
Informasi ing dokumen iki diwenehake mung kanggo referensi. ACCES ora nanggung tanggung jawab sing muncul saka aplikasi utawa panggunaan informasi utawa produk sing diterangake ing kene. Dokumen iki bisa ngemot utawa ngrujuk informasi lan produk sing dilindhungi hak cipta utawa paten lan ora menehi lisensi miturut hak paten ACCES, utawa hak wong liya.
IBM PC, PC/XT, lan PC/AT minangka merek dagang kadhaptar saka International Business Machines Corporation.
Dicithak ing AS. Hak cipta 2003, 2005 dening ACCES I / O Products, Inc.. 10623 Roselle Street, San Diego, CA 92121. Kabeh hak dilindhungi undhang-undhang.

WARNING!!
Tansah nyambung lan pedhot kabel lapangan karo daya komputer mati. Tansah nguripake POWER KOMPUTER
OFF sakdurunge INSTAL A BOARD. Nyambung lan medhot KABEL, UTAWA NGINSTAL PAPAN ING SISTEM KARO KOMPUTER UTAWA KEKUATAN LAPANGAN BISA njalari RUSAK ING PAPAN I/O lan bakal mbatalake KABEH JAMINAN, TERMASUK UTAWA
DIBUKA.

2

Manual 104-COM-8S

www.assured-systems.com | sales@assured-systems.com

Kaca 2/28

ACCES I/O 104-COM-8S Entuk Penawaran
Garansi
Sadurunge dikirim, peralatan ACCES dipriksa kanthi tliti lan diuji miturut spesifikasi sing ditrapake. Nanging, yen peralatan gagal, ACCES njamin para pelanggan manawa layanan lan dhukungan cepet bakal kasedhiya. Kabeh peralatan sing asline diprodhuksi dening ACCES sing ditemokake cacat bakal didandani utawa diganti miturut pertimbangan ing ngisor iki.
Sarat lan Ketentuan
Yen unit dicurigai gagal, hubungi departemen Layanan Pelanggan ACCES. Disiapake kanggo menehi nomer model unit, nomer seri, lan gambaran saka gejala gagal. Kita bisa uga menehi saran sawetara tes prasaja kanggo konfirmasi kegagalan. Kita bakal nemtokake nomer Return Material Authorization (RMA) sing kudu katon ing label njaba paket bali. Kabeh Unit / komponen kudu mlaku dikempalken kanggo nangani lan bali karo barang prabayar menyang ACCES ditetepake Service Center, lan bakal bali menyang customer / situs pangguna barang prabayar lan invoice.
Cakupan
Telung Taun Kapisan: Unit / bagean sing bali bakal didandani lan / utawa diganti ing pilihan ACCES tanpa biaya kanggo tenaga kerja utawa bagean sing ora dikecualekake kanthi garansi. Garansi diwiwiti kanthi pangiriman peralatan.
Taun-taun Sawise: Saklawase umur peralatan sampeyan, ACCES siyap nyedhiyakake layanan ing situs utawa ing pabrik kanthi tarif sing cukup padha karo manufaktur liyane ing industri kasebut.
Peralatan Ora Diprodhuksi dening ACCES
Peralatan sing disedhiyakake nanging ora diprodhuksi dening ACCES dijamin lan bakal didandani miturut syarat lan kahanan garansi pabrikan peralatan kasebut.
Umum
Ing Garansi iki, tanggung jawab ACCES diwatesi kanggo ngganti, ndandani utawa nerbitake kredit (miturut kawicaksanan ACCES) kanggo produk apa wae sing kabukten rusak sajrone periode garansi. Ing kasus apa ACCES tanggung jawab kanggo karusakan consequential utawa khusus teka saka nggunakake utawa nyalahi panggunaan saka produk kita. Pelanggan tanggung jawab kanggo kabeh biaya sing disebabake dening modifikasi utawa tambahan kanggo peralatan ACCES sing ora disetujoni kanthi nulis dening ACCES utawa, yen miturut pendapat ACCES, peralatan kasebut wis digunakake ora normal. "Panganggone ora normal" kanggo tujuan babar pisan iki ditetepake minangka panggunaan apa wae sing peralatan kasebut kapapar liyane saka panggunaan kasebut utawa dimaksudake minangka bukti saka perwakilan tuku utawa dodolan. Liyane saka ndhuwur, ora babar pisan liyane, ditulis utawa diwenehake, bakal ditrapake kanggo samubarang lan kabeh peralatan kuwi pepak utawa didol dening ACCES.

3
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 3/28

ACCES I/O 104-COM-8S Entuk Penawaran
DAFTAR ISI
BAB I : DESKRIPSI FUNGSI ……………………………………………………………….. 1
Gambar 1-1: DIAGRAM BLOK …………………………………………………………………………………………………. 6
BAB II : INSTALASI ……………………………………………………………… 2 Bab 7: PILIHAN PILIHAN …………………………………………………………………………… 3
Gambar 3-1: PETA PILIHAN PILIHAN ………………………………………………………………………………………………… 14
BAB 4 : PILIHAN ALAMAT ……………………………………………………………… 15
Tabel 4-1: TUGAS ALAMAT STANDARD UNTUK KOMPUTER ……………………………………………. 15 Tabel 4-2: ALAMAT JUMPERS ………………………………………………………………………………………. 16
BAB 5 : PEMROGRAMAN ………………………………………………………………………… 17
Tabel 5-1: Peta Daftar Blok Kontrol ………………………………………………………………………………………….. 17 Tabel 5-2: Peta Alamat EEPROM ……………………………………………………………………………………….. 17 Tabel 5-3: NILAI PEMBAHAGI RATE BAUD ………………………………………………………………… 19
Bab 6: TUGAS PIN KONEKTOR ………………………………………………………………. 22
Tabel 6-1: SAMBUNGAN PIN ………………………………………………………………………………………………… 22
BAB 7: SPESIFIKASI ………………………………………………………………… 23 LAMPIRAN A……………………………………………………………………………………. 24
Tabel A-1: ​​RS-422 RINGKASAN SPESIFIKASI………………………………………………………………………… 25 Gambar A-1: ​​Jaringan Umum RS-485 Two-Wire Multidrop ………………………………………………………….. 26

4
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 4/28

ACCES I/O 104-COM-8S Entuk Penawaran

Bab 1: DESKRIPSI FUNGSI
Papan Antarmuka Serial iki ngemot wolung utawa papat port independen lan nyedhiyakake komunikasi multipoint RS-485 lan RS422 sing efektif. Saben saluran bisa dikonfigurasi menyang salah siji mode. Jumpers ing Papan ngidini pilihan saka konfigurasi, kalebu mandap, kanggo saben saluran individu.
Papan dirancang ing format PC/104.
Ukurane kira-kira 3.775 inci X 3.550 inci. Kabeh sambungan sinyal digawe liwat konektor 50 pin, dipasang ing pinggir papan.
RS-485 BALANCED MODE OPERASI
Papan ndhukung mode RS-485 sing nggunakake pembalap imbang diferensial kanggo nambah kakebalan jangkoan lan gangguan. Spesifikasi RS-485 nemtokake maksimal 32 piranti ing siji baris. Jumlah piranti sing dilayani ing baris siji bisa ditambahi kanthi nggunakake "repeater".
Papan uga nduweni kemampuan kanggo nambah resistor beban kanggo mungkasi jalur komunikasi. Komunikasi RS-485 mbutuhake siji pemancar nyedhiyakake vol biastage kanggo mesthekake negara "nol" dikenal nalika kabeh pemancar mati. Uga, input panrima ing saben pungkasan jaringan kudu diakhiri kanggo ngilangi "dering". Papan iki ndhukung biasing minangka standar lan ndhukung mandap dening jumper ing Papan. Yen aplikasi sampeyan mbutuhake pemancar ora bias, hubungi pabrik.
Pembalap / panrima sing digunakake, jinis 75176B, bisa nyopir jalur komunikasi sing dawa banget kanthi tingkat baud sing dhuwur. Bisa drive nganti ± 60 mA ing garis imbang lan nampa input minangka kurang 200 mV sinyal diferensial superimposed ing swara mode umum +12 V utawa -7 V. Ing cilik saka konflik komunikasi, driver / panrima fitur mati termal.
Kompatibilitas PORT COMM
Tipe 16550 UART digunakake minangka Elemen Komunikasi Asynchronous (ACE) . Iki kalebu 16-bait ngirim / nampa buffer kanggo nglindhungi data ilang ing sistem operasi mbukak akeh tugas, nalika njaga 100% kompatibilitas karo port serial IBM asli. Nanging, port ora diwatesi kanggo alamat port COM standar.
Pilihan alamat terus-terusan kasedhiya ing ngendi wae ing sawetara alamat I / O 100 nganti 3F8 hex, lan program FINDBASE bakal mindai alamat sing dipetakan memori I / O Bus ing komputer kanggo alamat sing kasedhiya sing bisa digunakake tanpa konflik karo sumber daya komputer liyane. Iki ngidini port bisa digunakake minangka salah siji saka papat "standar" bandar COM (COM1 kanggo COM4), utawa coexist bebarengan karo wong-wong mau, ing kombinasi sembarang.
A osilator kristal dumunung ing Papan. Osilator iki ngidini pilihan baud rate sing tepat saka 300 nganti 921,600 kanthi osilator kristal standar. Osilator kristal standar digunakake kanggo ngasilake rong tingkat jam. Salah sijine yaiku jam standar 1.8432 MHz. Yen tingkat baud sing luwih dhuwur dibutuhake, tingkat 14.7456MHz bisa dipilih kanthi jumper.
MODUS KOMUNIKASI
Papan ndhukung komunikasi Half-Duplex karo sambungan kabel 2-kabel. Half-Duplex ngidini lalu lintas kanggo lelungan ing loro arah, nanging mung siji cara ing wektu. Komunikasi RS-485 umume nggunakake mode setengah dupleks amarga mung nuduhake sepasang kabel.

5
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 5/28

ACCES I/O 104-COM-8S Entuk Penawaran
KONTROL TRANSCEIVER AUTO-RTS Ing komunikasi RS-485, driver kudu diaktifake lan dipateni yen perlu, ngidini kabeh papan bisa nuduhake kabel loro kabel. Papan ngontrol driver kanthi otomatis. Kanthi kontrol otomatis, driver diaktifake nalika data siap dikirim. Pembalap tetep aktif kanggo wektu transmisi siji karakter sawise transfer data diwiwiti lan banjur dipateni. Panrima dipateni nalika transmisi RS-485 banjur diaktifake nalika driver pemancar dipateni. Papan kanthi otomatis nyetel wektu kanggo baud rate data. (CATETAN: Thanks kanggo fitur kontrol otomatis iki, Papan becik digunakake ing aplikasi Windows) Dhukungan IRQ Papan ndhukung nggunakake sumber daya IRQ, lan kalebu ndhaftar status IRQ ing Papan kanggo nggunakake sistem operasi sing ndhukung fitur iki, kayata Microsoft Windows NT. Iki ngidini papan kanggo nggunakake saka siji nganti limang tingkat IRQ kanggo ngontrol kabeh wolung bandar, nemen simplifying konfigurasi sistem.
Gambar 1-1: DIAGRAM BLOCK (Mung siji saluran serial sing ditampilake)

PC/104 BUS 50 PIN HEADER

AUTO RTS C IR CU ITRY

6
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 6/28

ACCES I/O 104-COM-8S Entuk Penawaran

BAB 2: INSTALASI

Pandhuan Miwiti Cepet (QSG) sing dicithak dikemas karo papan kanggo penak. Yen sampeyan wis nindakake langkah-langkah saka QSG, sampeyan bisa nemokake bab iki keluwih lan bisa nerusake kanggo miwiti ngembangake aplikasi sampeyan.
Piranti lunak sing disedhiyakake karo Papan PC/104 iki ana ing CD lan kudu diinstal ing hard disk sadurunge digunakake. Kanggo nindakake iki, tindakake langkah-langkah ing ngisor iki sing cocog kanggo sistem operasi sampeyan.
Instalasi CD

Pandhuan ing ngisor iki nganggep drive CD-ROM minangka drive "D". Ganti huruf drive sing cocog kanggo sistem sampeyan yen perlu.

DOS 1.
2.
3. 4.

Selehake CD menyang drive CD-ROM. Ketik B- kanggo ngganti drive aktif menyang drive CD-ROM. Ketik GLQR?JJ- kanggo mbukak program instalasi. Tindakake pituduh ing layar kanggo nginstal piranti lunak kanggo papan iki.

WINDOWS 1. Selehake CD menyang CD-ROM drive. 2. Sistem kudu mbukak program instalasi kanthi otomatis. Yen program instalasi ora mbukak kanthi cepet,
klik START | RUN banjur ketik BGLQR?JJ, klik OK utawa pencet -. 3. Tindakake pituduh ing layar kanggo nginstal piranti lunak kanggo Papan iki.

LINUX 1. Mangga deleng linux.htm ing CD-ROM kanggo informasi nginstall port serial ing linux.

7
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 7/28

ACCES I/O 104-COM-8S Entuk Penawaran
Nginstal Hardware
Sadurunge nginstal papan, waca kanthi teliti Bab 3 lan Bab 4 saka manual iki lan atur papan miturut syarat sampeyan. Program SETUP bisa digunakake kanggo ngewangi konfigurasi jumper ing papan. Ati-ati banget karo Pilihan Alamat. Yen alamat rong fungsi sing diinstal tumpang tindih, sampeyan bakal ngalami prilaku komputer sing ora bisa diramal. Kanggo ngindhari masalah iki, deleng program FINDBASE.EXE sing diinstal saka CD. Program persiyapan ora nyetel pilihan ing Papan, iki kudu disetel dening jumper.
Papan komunikasi serial multi-port iki nggunakake kisaran alamat sing bisa diprogram piranti lunak kanggo saben UART, sing disimpen ing EEPROM onboard. Konfigurasi alamat EEPROM nggunakake blok jumper Pilihan Alamat onboard, banjur gunakake program Setup sing kasedhiya kanggo ngatur alamat kanggo saben UART onboard.
Kanggo Instal Papan
1. Instal jumper kanggo opsi sing dipilih lan alamat dhasar miturut syarat aplikasi, kaya kasebut ing ndhuwur.
2. Copot daya saka PC / 104 tumpukan. 3. Nglumpukake hardware standoff kanggo numpuk lan ngamanake Boards. 4. Pasang papan kasebut kanthi teliti ing konektor PC/104 ing CPU utawa ing tumpukan, mesthekake
alignment saka lencana sadurunge rampung lelenggahan konektor bebarengan. 5. Pasang kabel I/O menyang konektor I/O papan lan nerusake kanggo ngamanake tumpukan bebarengan utawa baleni
langkah 3-5 nganti kabeh Papan diinstal nggunakake hardware soyo tambah milih. 6. Priksa manawa kabeh sambungan ing tumpukan PC / 104 wis bener lan aman banjur daya sistem. 7. Mbukak siji saka kasedhiya sample program cocok kanggo sistem operasi sing wis diinstal
saka CD kanggo nyoba lan ngesyahke instalasi sampeyan.
Nginstal Port COM ing Sistem Operasi Windows
* CATETAN: Papan COM bisa diinstal ing meh kabeh sistem operasi lan kita ndhukung instalasi ing versi sadurungé saka windows, lan banget kamungkinan kanggo ndhukung versi mangsa uga. Kanggo nggunakake ing WinCE, hubungi pabrik kanggo instruksi tartamtu.
Windows NT4.0
Kanggo nginstal port COM ing Windows NT4 sampeyan kudu ngganti siji entri ing pendaptaran. Entri iki ngidini enggo bareng IRQ ing papan COM multi-port. Kuncine yaiku HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesSerial. Jeneng nilai kasebut PermitShare lan data kudu disetel dadi 1.
Sampeyan banjur bakal nambah bandar Papan minangka bandar COM, nyetel alamat dhasar lan IRQ kanggo cocog setelan Papan kang.
Kanggo ngganti nilai pendaptaran, mbukak RegEdit saka START|RUN pilihan menu (kanthi ngetik REGEDIT [ENTER] ing spasi kasedhiya). Navigasi mudhun wit view ing sisih kiwa kanggo nemokake tombol, lan klik kaping pindho ing jeneng nilai kanggo mbukak dialog ngijini sampeyan kanggo nyetel Nilai data anyar.

8
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 8/28

ACCES I/O 104-COM-8S Entuk Penawaran

Kanggo nambah port COM, gunakake START|CONTROL PANEL|PORTS applet lan klik ADD, banjur ketik alamat UART sing bener lan nomer Interrupt. Nalika dialog "Tambah Port Anyar" dikonfigurasi klik OK, nanging wangsulane "Aja Wiwiti maneh Saiki" nalika dijaluk, nganti sampeyan uga nambahake port liyane. Banjur miwiti maneh sistem kanthi normal, utawa kanthi milih "Wiwiti maneh Saiki."
Windows XP
Kanggo nginstal port COM ing Windows XP sampeyan bakal nginstal port komunikasi "standar" kanthi manual, banjur ngganti setelan kanggo sumber daya sing digunakake dening port kanggo cocog karo hardware. Bukak applet "Tambah Hardware" saka Panel Kontrol. Klik "Sabanjure" ing dialog "Welcome to Add New Hardware Wizard". Sampeyan bakal weruh pesen "... searching ...", banjur Pilih "Ya, aku wis nyambung hardware" lan Klik "Sabanjure"

Pilih "Tambah piranti hardware anyar" saka ngisor dhaptar sing ditampilake lan Klik "Sabanjure." Pilih "Instal hardware sing aku pilih kanthi manual saka dhaptar" lan Klik "Sabanjure." Pilih "Ports (COM & LPT) lan Klik "Next" Pilih "(Jenis Port Standar)" lan "Port Komunikasi" (standar), Klik "Next." Klik "Sabanjure."

9

Manual 104-COM-8S

www.assured-systems.com | sales@assured-systems.com

Kaca 9/28

ACCES I/O 104-COM-8S Entuk Penawaran
Klik ing "View utawa ngganti sumber kanggo hardware iki (Advanced) ”link.

Klik tombol "Setel Konfigurasi Manual". Pilih "Konfigurasi Dasar 8" saka dhaptar gulung "Setelan Adhedhasar:". Pilih "I/O Range" ing kothak "Resource Settings" lan Klik tombol "Change Settings ...". Ketik alamat dhasar papan, banjur Klik "OK"

10
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 10/28

ACCES I/O 104-COM-8S Entuk Penawaran

Pilih "IRQ" ing kothak "Resource Settings" lan Klik tombol "Ganti Setelan". Ketik IRQ saka Papan lan Klik "OK". Nutup dialog "Setel Konfigurasi Manual" lan klik "Rampung." Klik "Aja Urip maneh" yen sampeyan pengin nginstal port liyane. Baleni kabeh langkah ing ndhuwur, ngetik IRQ padha nanging nggunakake alamat Base diatur kanggo saben UART tambahan. Yen wis rampung nginstal port, urip maneh sistem kanthi normal.

11
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 11/28

ACCES I/O 104-COM-8S Entuk Penawaran

Bab 3: PILIHAN PILIHAN
Kanggo mbantu sampeyan nemokake jumper sing diterangake ing bagean iki, deleng PETA PILIHAN PILIHAN ing pungkasan bagean iki. Operasi bagean komunikasi serial ditemtokake dening instalasi jumper minangka diterangake ing paragraf ing ngisor iki.

TERM

120 S

TERMINATIONS:
Saluran transmisi kudu diakhiri ing mburi panampa kanthi impedansi karakteristik. Nginstal jumper ing lokasi label TERM ditrapake 120 mbukak liwat ngirim / nampa input / output kanggo operasi RS-485.
Ing operasi RS-485 ing ngendi ana pirang-pirang terminal, mung port RS-485 ing saben ujung jaringan kudu duwe resistor terminating kaya sing kasebut ing ndhuwur. Uga, kanggo operasi RS-485, kudu ana bias ing garis RX + lan RX-. Yen papan ora nyedhiyakake bias kasebut, hubungi dhukungan teknis pabrik.
KABEL DATA WIRING
INTERRUPTS: Papan ndhukung IRQ 2, 3, 5, 7, 10 lan 11 (kajaba dilindhungi undhang-undhang dening hardware diinstal liyane). Tingkat dipilih kanthi nulis tingkat IRQ sing dikarepake menyang alamat sing cocog ing EEPROM lan diunggahake saka EEPROM menyang register sing cocog. Saluran A, B, C lan D duwe interupsi individu lan saluran E, F, G lan H nuduhake interupsi kaping lima. Sampeyan kudu mbukak nilai interupsi kanggo kabeh saluran. Yen interrupt sing padha digunakake kanggo kabeh saluran, kudu dilebokake ing kabeh limang lokasi interupsi ing EEPROM.
Wigati dimangerteni: Ing Windows NT, owah-owahan kudu digawe ing Registry Sistem kanggo ndhukung enggo bareng IRQ. Ing ngisor iki dijupuk saka "Controlling Multiport Serial I / O Boards" diwenehake dening Microsoft ing perpustakaan MSDN. Document id: mk:@ivt:nt40res/D15/S55FC.HTM, uga kasedhiya ing Windows NT Resource Kit. Teks sing dikurung ing kurung (“[]”) nuduhake komentar.
Pembalap serial Microsoft bisa digunakake kanggo ngontrol akeh papan serial multiport bisu. Bisu nuduhake yen kontrol ora kalebu prosesor ing papan. Saben port papan multiport nduweni subkunci sing kapisah ing subkunci CurrentControlSetServicesSerial ing Registry. Ing saben subkunci kasebut, sampeyan kudu nambahake nilai kanggo DosDevices, Interrupt, InterruptStatus, Port Address, lan PortIndex amarga iki ora dideteksi dening Hardware Recognizer. (Kanggo katrangan lan kisaran kanggo nilai kasebut, deleng Regentry.hlp, bantuan Registry file ing CD Windows NT Workstation Resource Kit.)

12
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 12/28

ACCES I/O 104-COM-8S Entuk Penawaran

Kanggo example, yen sampeyan duwe papan sing dikonfigurasi karo blok kontrol ing alamat 0x300, port consecutive lan contiguous diwiwiti ing alamat 0x100, lan IRQ 0x5 ing kabeh port, nilai ing Registry yaiku:

Subkunci Serial2: PortAddress = REG_DWORD 0x100 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM3 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 1
Subkunci Serial3: PortAddress = REG_DWORD 0x108 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM4 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 2
Subkunci Serial4: PortAddress = REG_DWORD 0x110 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM5 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 3
Subkunci Serial5: PortAddress = REG_DWORD 0x118 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM6 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 4

Subkunci Serial6: PortAddress = REG_DWORD 0x120 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM7 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 5
Subkunci Serial7: PortAddress = REG_DWORD 0x128 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM8 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 6
Subkunci Serial8: PortAddress = REG_DWORD 0x130 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM9 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 7
Subkunci Serial9: PortAddress = REG_DWORD 0x138 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM10 InterruptStatus = REG_DWORD 0x500 PortIndex = REG_DWORD 8

Entri InterruptStatus dadi 0x500 rada ora biasa; iku alamat dhasar saka port pisanan plus 0x400. Iki biasane bakal dadi alias saka port pisanan, nanging papan nggunakake alamat alias iki kanggo daftar status.

13
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 13/28

ACCES I/O 104-COM-8S Entuk Penawaran

P2
pin 1

A5 A6 A7 A8 A9 COM A DF

COM C

KOMUNITAS E

KOM G

42 2 RL D TLD 4 22 R LD TLD 422 RL D TLD 42 2 R LD T LD

4 22 RL D TLD 4 22 RL D TLD 4 22 RL D TLD 4 22 RL D TLD

COM B COM D COM F COM H

CLK x8 A485 B485 C485 D485 E485 F485 G485 H485

Gambar 3-1: PETA PILIHAN PILIHAN

14
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 14/28

ACCES I/O 104-COM-8S Entuk Penawaran

Bab 4: PILIHAN ALAMAT

Saben alamat pangkalan port bisa dipilih ing ngendi wae ing sawetara alamat I/O 100-3F8 hex, nyedhiyakake alamat kasebut ora tumpang tindih karo fungsi liyane. Yen ragu, deleng tabel ing ngisor iki kanggo dhaptar tugas alamat standar. (Port komunikasi sinkron binar utami lan sekunder didhukung dening Sistem Operasi.) Program pencari alamat basis FINDBASE sing diwenehake karo papan sampeyan bakal mbantu sampeyan milih alamat dhasar sing bakal nyegah konflik iki.
Tabel 4-1: TUGAS ALAMAT STANDARD UNTUK KOMPUTER

HEX RANGE panggunaan

000-00F 020-021 040-043 060-06F 070-07F 080-09F 0A0-0BF 0C0-0DF 0F0-0F1 0F8-0FF 170-177 1F0-1F8 200-207 238-23B 23C-23F 278-27F 2B0-2BF 2C0-2CF 2D0-2DF 2E0-2E7 2E8-2EF 2F8-2FF 300-30F 310-31F 320-32F 370-377 378-37F 380-38F 3A0-3AF 3B0-3BB 3BC-3BF 3C0-3CF 3D0-3DF 3E8-3EF 3F0-3F7 3F8-3FF

8237 DMA Controller 1 8259 Interrupt 8253 Timer 8042 Keyboard Controller CMOS RAM, NMI Mask Reg, RT Jam DMA Page Register 8259 Budak Interrupt Controller 8237 DMA Controller 2 Math Coprocessor Math Coprocessor Fixed Disk Controller 2 Fixed Disk Mouse Controller 1 Game Port Bus Mouse Controller. Printer Paralel Mouse Bus EGA EGA EGA GPIB (AT) Port Serial Port Serial dilindhungi undhang-undhang Hard Disk (XT) Pengontrol Floppy 2 Printer Paralel SDLC SDLC MDA Printer Paralel VGA EGA CGA Port Serial Pengontrol Floppy 1 Port Serial

15
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 15/28

ACCES I/O 104-COM-8S Entuk Penawaran

Jumper alamat nemtokake alamat blok kontrol; alamat lan interrupts bandar dijupuk saka EEPROM onboard. Register sharing interrupt (utamane digunakake ing NT4) dirujuk menyang alamat Channel A.

Byte alamat sing dilebokake ing EEPROM makili garis alamat A9 nganti A3. Cara paling gampang kanggo nemtokake bait kanggo nulis alamat sing dikarepake yaiku dibagi alamat kanthi 8. Contone, alamat basis 300 bakal dadi 300/8 = 60, alamat 308/8 = 61, lan liya-liyane. (Kabeh alamat ana ing hex.)

Tabel 4-2: ALAMAT JUMPERS

Angka 1

Angka 2

Label Jumper

A9 A8 A7 A6 A5 —

Alamat Line Controlled A9 A8 A7 A6 A5 A4

Nilai Heksadesimal

200 100 80 40 20 10

Kanggo maca persiyapan jumper alamat, nemtokaken binar "1" kanggo jumper sing ora diinstal lan binar "0" kanggo jumper diinstal. Kanggo example, kaya sing digambarake ing tabel ing ngisor iki, pilihan jumper cocog karo binar 10 000x xxxx (hex 200). "xxx" makili baris alamat A4, A3, A2, A1, lan A0 digunakake ing Papan kanggo milih ndhaftar individu, minangka diterangake ing bagean PROGRAMMING manual iki.

EXAMPLE ADDRESS SETUP

Jumper Label Konversi Faktor Jumper Dipasang Binar Representasi Hex

A9 A8 A7 A6 A5

2 1

8

4 2

ORA YA YA YA

1 0

0

0 0

2

0

Review TABEL PILIHAN ALAMAT kanthi teliti sadurunge milih alamat papan. Yen alamat rong fungsi sing diinstal tumpang tindih, sampeyan bakal nemu prilaku komputer sing ora bisa ditebak.

16
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 16/28

ACCES I/O 104-COM-8S Entuk Penawaran

Bab 5: PEMROGRAMAN
Alamat port lan IRQ dipilih dening piranti lunak liwat blok kontrol; alamat dhasar saka pemblokiran kontrol dipilih dening jumpers. Fungsi ing blok kontrol ditampilake ing peta daftar blok kontrol ing ngisor iki.
Tabel 5-1: Peta Register Blok Kontrol

alamat

Maca Fungsi

Tulis Fungsi

Alamat dhasar + 0

Alamat Base + 1 Alamat EEPROM

Alamat EEPROM

Alamat dhasar + 2

EEPROM data

Alamat dhasar + 3

Muat EEPROM Kanggo Register

Alamat lan IRQ saka bandar dijupuk saka EEPROM ing Papan. Saliyane kanthi otomatis mbukak ing daya-on, padha bisa dimuat dening piranti lunak dening nulis menyang pemblokiran kontrol. Alamat lan interrupts disimpen ing EEPROM minangka ditampilake ing peta alamat EEPROM ing ngisor iki.
Tabel 5-2: Peta Alamat EEPROM

Alamat EEPROM Tegese Data EEPROM

1

Alamat kanggo Saluran A

2

Alamat kanggo Saluran B

3

Alamat kanggo Saluran C

4

Alamat kanggo Saluran D

5

Alamat kanggo Saluran E

6

Alamat kanggo Saluran F

7

Alamat kanggo Saluran G

8

Alamat kanggo Saluran H

9

IRQ kanggo Saluran A

A

IRQ kanggo Saluran B

B

IRQ kanggo Saluran C

C

IRQ kanggo Saluran D

D

IRQ kanggo Saluran E, F, G & H

Kaya sing kasebut ing papan liya, alamat sing dilebokake makili A3 - A9. Mulane, data sing dilebokake yaiku alamat sing dikarepake, dibagi 8.
Nalika Papan pisanan diinstal ing sistem, bandar ora kudu ing alamat sing ora digunakake. Kanggo nyegah konflik karo piranti liyane ing sistem, Papan wis jumper sing disables bandar, jejere jumper alamat basa lan labeled "DF". Blok kontrol tetep diaktifake ing mode iki, ngidini piranti lunak disetel

17

Manual 104-COM-8S

www.assured-systems.com | sales@assured-systems.com

Kaca 17/28

ACCES I/O 104-COM-8S Entuk Penawaran
alamat port cocok. Nalika jumper DF banjur dibusak, bandar banjur bakal ing alamat diatur.
Kanggo nulis data menyang EEPROM, tulis dhisik alamat kasebut menyang registrasi Alamat EEPROM, banjur tulis utawa waca saka registrasi Data EEPROM. Kanggo example, kanggo nyetel Saluran A menyang alamat 3F8, IRQ 5, kanthi alamat basis blok kontrol disetel dadi 200 (dening jumper):
Tulis 01 nganti 201. Tulis 7F nganti 202. Tulis 09 nganti 201. Tulis 05 nganti 202. Banjur tulisake apa wae nganti 203 kanggo miwiti nggunakake nilai kasebut.
Kabeh data bisa dilebokake ing EEPROM banjur ditulis menyang register sing cocog kanthi nulis siji menyang alamat dhasar + 3.
SAMPPROGRAM LE
Ana loro sample program diinstal karo CD sing dikirim karo Papan. Iki yaiku:
Sample 1 Program iki kasedhiya ing C, Pascal, lan QuickBASIC. Iku nindakake tes fitur loopback saka UART. Ora mbutuhake hardware eksternal lan ora ana gangguan.
Sample 2 Program iki kasedhiya mung ing C lan nduduhake operasi setengah duplex RS-485 interrupt-driven. Program kasebut mbutuhake paling ora rong komputer kanthi papan siji lan kabel loro-kabel sing nyambungake. Kabel kasebut kudu nyambungake pin Tx saka papan 1 menyang pin Rx saben papan 2 lan pin Tx saka papan 2 menyang pin Rx ing papan 1.
Papan 1 nganti Papan 2 TRx- 3 ÅÆ TRx- 3 TRx+ 2 ÅÆ TRx+ 2

18
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 18/28

ACCES I/O 104-COM-8S Entuk Penawaran

PEMROGRAMAN RS-485
Pemrograman UART kanggo komunikasi RS-485 bisa dipérang dadi telung bagean sing béda: inisialisasi, resepsi, lan transmisi. Initialization menehi hasil karo persiyapan pilihan ing chip kalebu pilihan baud rate. Resepsi urusan karo pangolahan karakter mlebu sing bisa ditindakake kanthi nggunakake polling utawa interrupts. Transmisi urusan karo proses ngirim data metu.
INISIALISASI
Initializing chip mbutuhake kawruh saka pesawat register UART. Langkah pisanan yaiku nyetel pembagi tingkat baud. Sampeyan nindakake iki kanthi nyetel DLAB (Divisor Latch Access Bit) dhuwur. Bit iki Bit 7 ing Alamat Base +3. Ing kode C, telpon bakal dadi:
outportb(BASEADDR +3,0×80);
Sampeyan banjur mbukak divisor menyang Alamat Base +0 (byte kurang) lan Alamat Base +1 (byte dhuwur). Persamaan ing ngisor iki nemtokake hubungan antarane baud rate lan divisor:
baud rate sing dikarepake = (frekuensi kristal) / (32 * pembagi)
Ing papan kasebut, frekuensi jam 1.8432 MHz (Standar) lan 14.7456 MHz (X8) diwenehake. Ing ngisor iki minangka tabel kanggo frekuensi pembagi sing populer:
Tabel 5-3: BAUD RATE DIVISOR NILAI

Baud Rate Divisor (Std) Divisor (X8)

Cathetan

Panjang Kabel Maks (ft)

921600

1

250

460800

2

550

230400

4

1400

115200

1

8

3000

57600

2

16

4000

38400

3

24

4000

28800

4

32

4000

19200

6

48

4000

14400

8

64

4000

9600

12

96

Paling Umum

4000

4800

24

192

4000

2400

48

384

4000

1200

96

768

4000

* Jarak maksimum sing disaranake kanggo kabel data sing didorong kanthi beda (RS422 utawa RS-485) kanggo kahanan sing khas. Garis komunikasi RS-232 nduweni dawa maksimum 50 kaki, preduli saka kacepetan.

19
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 19/28

ACCES I/O 104-COM-8S Entuk Penawaran

Ing C, kode kanggo nyetel chip menyang 9600 baud yaiku:

outportb(BASEADDR, 0x0C); outportb(BASEADDR +1,0);

Langkah initializing kapindho yaiku nyetel Line Control Register ing Alamat Base +3. Register iki nemtokake dawa tembung, bit mandeg, paritas, lan DLAB.

Bit 0 lan 1 ngontrol dawa tembung lan ngidini dawa tembung saka 5 nganti 8 bit. Setelan bit diekstrak kanthi nyuda 5 saka dawa tembung sing dikarepake.

Bit 2 nemtokake jumlah bit mandeg. Bisa uga ana siji utawa loro stop bit. Yen Bit 2 disetel dadi 0, bakal ana siji mandeg bit. Yen Bit 2 disetel dadi 1, bakal ana rong bit mandeg.

Bit 3 nganti 6 kontrol paritas lan break ngaktifake. Ora umum digunakake kanggo komunikasi lan kudu disetel menyang nol.

Bit 7 minangka DLAB sing dibahas sadurunge. Sampeyan kudu disetel menyang nol sawise divisor dimuat utawa ora bakal ana komunikasi.

Perintah C kanggo nyetel UART kanggo tembung 8-bit, ora paritas, lan siji mandeg bit yaiku:

outportb(BASEADDR +3, 0x03)

Langkah initialization final kanggo flush buffer panrima. Sampeyan nindakake iki karo loro maca saka buffer panrima ing Base Address +0. Yen wis rampung, UART siap digunakake.

RESEPSI

Resepsi bisa ditangani kanthi rong cara: polling lan interrupt-driven. Nalika polling, resepsi ditindakake kanthi terus maca Register Status Line ing Alamat Base +5. Bit 0 saka register iki disetel dhuwur nalika data siap diwaca saka chip. A daur ulang polling prasaja kudu terus-terusan mriksa bit iki lan maca ing data minangka kasedhiya. Fragmen kode ing ngisor iki ngetrapake loop polling lan nggunakake nilai 13, (ASCII Carriage Return) minangka tandha pungkasan transmisi:

nindakake {
nalika (!(inportb(BASEADDR +5) & 1)); data[i++]= inportb(BASEADDR); } nalika (data[i]!=13);

/*Enteni nganti data siap*/ /*Maca baris nganti karakter null rec'd*/

Komunikasi interrupt-driven kudu digunakake sawayah-wayah lan dibutuhake kanggo tarif data dhuwur. Nulis panrima interrupted-driven ora luwih rumit tinimbang nulis panrima polling nanging kudu ati-ati nalika nginstal utawa mbusak handler interrupt supaya ora nulis interupsi sing salah, mateni interupsi sing salah, utawa mateni interupsi kanggo wektu sing suwe.

Pawang pisanan bakal maca Register Identifikasi Interupsi ing Alamat Base +2. Yen interupsi kanggo Data Ditampa kasedhiya, pawang banjur maca data kasebut. Yen ora ana interupsi sing ditundha, kontrol metu saka rutinitas. A sample handler, ditulis ing C, minangka nderek:

readback = inportb(BASEADDR +2);

yen (baca maneh & 4)

/*Waca maneh bakal disetel dadi 4 yen data kasedhiya*/

data[i++]=inportb(BASEADDR);

outportb(0x20,0x20); /*Tulis EOI menyang 8259 Interrupt Controller*/

bali;

20

Manual 104-COM-8S

www.assured-systems.com | sales@assured-systems.com

Kaca 20/28

ACCES I/O 104-COM-8S Entuk Penawaran

TRANSMISI

Transmisi RS-485 gampang dileksanakake. Fitur AUTO saka papan kanthi otomatis ngaktifake pemancar nalika data wis siyap kanggo dikirim supaya ora ana piranti lunak sing dibutuhake.

Kanggo ngirim senar data, pemancar kudu mriksa Bit 5 saka Daftar Status Line ing Alamat Base +5. Sing bit iku gendéra pemancar-nyekel-register-kosong. Yen dhuwur, pemancar wis ngirim data kasebut. Proses mriksa bit nganti dhuwur banjur ditulis diulang nganti ora ana data.

Fragmen kode C ing ngisor iki nuduhake proses iki:

outportb(BASEADDR +4, inportb(BASEADDR +4)|0x02);

/*Setel bit RTS tanpa ngganti status bit liyane*/

while(data[i]);

/*Nalika ana data sing kudu dikirim*/

{

while(!(inportb(BASEADDR +5)&0x20)); /*Tunggu nganti pemancar kosong*/

outportb(BASEADDR,data[i]);

i++;

}

outportb(BASEADDR +4, inportb(BASEADDR +4)&0xFD);

/*Reset bit RTS tanpa ngganti status bit liyane*/

21
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 21/28

ACCES I/O 104-COM-8S Entuk Penawaran
Bab 6: TUGAS PIN KONEKTOR
A 50-pin Male IDC Header kasedhiya ing Papan. Pinout kanggo konektor iki nderek. kabel pilihan ngilangi 50 Pin Header mudhun kanggo 8, konektor DB9 Male.

Tabel 6-1: SAMBUNGAN PIN

Pin # RS-485 Fungsi RS-422 Fungsi Pin # RS-485 Fungsi RS-422

1

lemah

lemah

26

Ch E Tx + lan Rx +

Ch E Tx +

2

Ch A Tx + lan Rx +

Ch A Tx +

27

Ch E Tx lan Rx -

Ch E Tx -

3

Ch A Tx lan Rx -

Ch A Tx -

28

lemah

lemah

4

lemah

lemah

29

Ch E Rx +

5

Ch A Rx +

30

Ch E Rx -

6

Ch A Rx -

31

lemah

lemah

7

lemah

lemah

32

Ch F Tx + lan Rx +

Ch F Tx +

8

Ch B Tx + lan Rx +

Ch B Tx +

33

Ch F Tx lan Rx -

Ch F Tx –

9

Ch B Tx lan Rx -

Ch B Tx –

34

lemah

lemah

10

lemah

lemah

35

Ch F Rx +

11

Ch B Rx +

36

Ch F Rx –

12

Ch B Rx -

37

lemah

lemah

13

lemah

lemah

38

Ch G Tx + lan Rx +

Ch G Tx +

14

Ch C Tx + lan Rx +

Ch C Tx +

39

Ch G Tx lan Rx -

Ch G Tx –

15

Ch C Tx lan Rx –

Ch C Tx –

40

lemah

lemah

16

lemah

lemah

41

Ch G Rx +

17

Ch C Rx +

42

Ch G Rx -

18

Ch C Rx –

43

lemah

lemah

19

lemah

lemah

44

Ch H Tx + lan Rx +

Ch H Tx +

20

Ch D Tx + lan Rx +

Ch D Tx +

45

Ch H Tx lan Rx -

Ch H Tx –

21

Ch D Tx lan Rx -

Ch D Tx -

46

lemah

lemah

22

lemah

lemah

47

Ch H Rx +

23

Ch D Rx +

48

Ch H Rx –

24

Ch D Rx -

49

lemah

lemah

25

lemah

lemah

50

lemah

lemah

22

Manual 104-COM-8S

www.assured-systems.com | sales@assured-systems.com

Kaca 22/28

ACCES I/O 104-COM-8S Entuk Penawaran

BAB 7: SPESIFIKASI

ANTARA FUNGSI KOMUNIKASI

Siji konektor 50 pin diwenehake

Ana wolung pin saben port plus latar umum

Dawane karakter: 5,6,7, utawa 8 bit

Paritas:

Malah, aneh, utawa ora ana

Stop Interval:

1, 1.5 utawa 2 bit

Tarif Data Serial: Nganti 115.2K baud, ora sinkron. A sawetara luwih cepet saka tarif, nganti 921.6K, punika

digayuh kanthi pilihan jumper

Multidrop:

Kompatibel karo spesifikasi RS-485. Nganti 32 pembalap lan panrima sing diidini

ing baris. Driver/Receiver sing digunakake yaiku tipe 75ALS180

Kompatibel karo spesifikasi RS-422. Nganti sepuluh panrima diijini ing baris.

alamat:

ISA BUS alamat disetel dening jumpers ing Papan. Alamat saluran yaiku

tansah dimuat saka memori non-molah malih

Interrupts:

IRQ individu kanggo saben saluran disimpen ing papan ing memori non-molah malih

Sensitivitas Input Receiver:

± 200 mV input diferensial

Mode Umum Voltage Range: + 12V kanggo -7V Transmitter

Kapabilitas Drive Output:

60 mA karo mati termal.

mandhek:

Terminasi sing bisa dipilih jumper kanggo input lan output, miturut saluran, diwenehake.

Bias uga diwenehake.

LINGKUNGAN

Kisaran Suhu Operasi: 0 nganti +60 °C

Kisaran Suhu Panyimpenan: -50 nganti +120 °C

Kelembapan:

5% nganti 95%, non-kondensasi.

Daya sing dibutuhake:

+5 VDC ing 400 mA khas, 800 mA maksimum.

ukuran:

Format PC/104, 3.5″ x 3.75″.

23
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 23/28

ACCES I/O 104-COM-8S Entuk Penawaran
LAMPIRAN A
KONSIDERASI APLIKASI
PAMBUKA
Nggarap piranti RS-485 ora beda karo nggarap piranti serial RS-232 standar lan standar iki ngatasi kekurangan ing standar RS-232. Pisanan, dawa kabel antarane rong piranti RS-232 kudu cendhak; kurang saka 50 kaki. Kapindho, akeh kesalahan RS-232 minangka asil gangguan sing disebabake ing kabel. Standar RS-485 ngidini dawa kabel nganti 4000 kaki lan, amarga beroperasi ing mode diferensial, luwih kebal marang gangguan sing disebabake.
Kekurangan katelu RS-232 yaiku luwih saka rong piranti ora bisa nganggo kabel sing padha. Iki uga bener kanggo RS422 nanging RS-485 nawakake kabeh keuntungan saka RS422 plus ngidini nganti 32 piranti kanggo nuduhake pasangan bengkong padha. Pangecualian kanggo sing kasebut ing ndhuwur yaiku sawetara piranti RS422 bisa nuduhake kabel siji yen mung siji sing bakal ngomong lan liyane bakal nampa.
BALANCED DIFFERENTIAL SIGNALS
Alesan yen piranti RS422 lan RS-485 bisa nyopir garis sing luwih dawa kanthi kekebalan gangguan luwih akeh tinimbang piranti RS-232 amarga metode drive diferensial sing seimbang digunakake. Ing sistem diferensial imbang, voltage sing diprodhuksi dening driver katon ing sepasang kabel. A pembalap baris imbang bakal gawé vol diferensialtage saka ± 2 kanggo ± 6 volt ing terminal output sawijining. Pembalap baris sing seimbang uga bisa duwe sinyal "aktif" input sing nyambungake driver menyang terminal output. Yen sinyal "aktif" OFF, pembalap wis pedhot saka saluran transmisi. Kawontenan pedhot utawa dipatèni iki biasane diarani minangka kondisi "tristate" lan makili impedansi dhuwur. Pembalap RS-485 kudu nduweni kemampuan kontrol iki. Pembalap RS422 bisa uga duwe kontrol iki nanging ora mesthi dibutuhake.
A panrima baris diferensial imbang ngrasakake voltage negara baris transmisi liwat loro baris input sinyal. Yen input diferensial voltage luwih saka +200 mV, panrima bakal nyedhiyani negara logika tartamtu ing output. Yen diferensial voltage input kurang saka -200 mV, panrima bakal nyedhiyani negara logika ngelawan ing output sawijining. Volume operasi maksimumtage sawetara saka + 6V kanggo -6V ngidini kanggo voltage atenuasi sing bisa dumadi ing kabel transmisi dawa.
Mode umum maksimum voltage rating ± 7V menehi kakebalan gangguan apik saka voltaginduksi ing garis pasangan bengkong. Sambungan garis lemah sinyal perlu kanggo njaga vol mode umumtage ing kisaran kasebut. Sirkuit kasebut bisa digunakake tanpa sambungan lemah nanging bisa uga ora bisa dipercaya.

24
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 24/28

ACCES I/O 104-COM-8S Entuk Penawaran

Tabel A-1: ​​RS-422 RINGKASAN SPESIFIKASI

Paramèter

Syarat Min.

Maks.

Output Driver Voltage (dibongkar)

4V

6V

-4V

-6V

Output Driver Voltage (dimuat)

TERM jumper ing 2V -2V

Resistance Output Driver

50

Driver Output Short-Circuit Saiki

± 150 mA

Wektu Rise Output Driver

10% interval unit

Sensitivitas panrima

± 200 mV

Receiver Mode Umum Voltage Range

± 7V

Resistance Input panrima

4K

Kanggo nyegah bayangan sinyal ing kabel lan nambah nolak gangguan ing mode RS422 lan RS-485, ujung panrima kabel kudu diakhiri kanthi resistensi sing padha karo impedansi karakteristik kabel. (Istiméwa iku nalika baris mimpin dening pembalap RS422 sing tau "tristatated" utawa pedhot saka baris. Ing kasus iki, driver menehi impedansi internal kurang sing terminates baris ing mburi.)
CATETAN
Sampeyan ora kudu nambah resistor terminator kanggo kabel nalika sampeyan nggunakake Papan. Resistor mandap kanggo RX + lan RX- garis kasedhiya ing Papan lan diselehake ing sirkuit nalika sampeyan nginstal LOAD (LD) jumper. (Deleng bagean Pilihan Pilihan ing manual iki.)

25
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 25/28

ACCES I/O 104-COM-8S Entuk Penawaran
TRANSMISI DATA RS-485 Standar RS-485 ngidini saluran transmisi sing seimbang dienggo bareng ing mode baris partai. Minangka akeh minangka 32 driver / pasangan panrima bisa nuduhake loro-kabel jaringan baris party. Akeh karakteristik saka pembalap lan panrima padha ing RS422 Standard. Siji prabédan yaiku mode umum voltagwatesan e wis lengkap lan + 12V kanggo -7V. Wiwit sembarang driver bisa pedhot (utawa tristated) saka baris, iku kudu tahan iki mode umum voltage sawetara nalika ing kondisi tristate.
RS-485 Two-Wire Multidrop Network Ilustrasi ing ngisor iki nuduhake jaringan multidrop utawa party line khas. Elinga yen baris transmisi wis mungkasi ing loro ends saka baris nanging ora ing titik drop ing tengah baris.

Gambar A-1: ​​Jaringan Multidrop Dua Kawat Khas RS-485

26
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 26/28

ACCES I/O 104-COM-8S Entuk Penawaran
Komentar Pelanggan
Yen sampeyan nemu masalah karo manual iki utawa mung arep menehi sawetara saran, please email kita ing: manuals@accesio.com. Mangga rinci babagan kesalahan sing sampeyan temokake lan lebokake alamat surat supaya kita bisa ngirim nganyari manual.

10623 Roselle Street, San Diego CA 92121 Tel. (858)550-9559 FAX (858)550-7322 www.accesio.com

27
www.assured-systems.com | sales@assured-systems.com

Manual 104-COM-8S
Kaca 27/28

ACCES I/O 104-COM-8S Entuk Penawaran
Sistem Terjamin
Assured Systems minangka perusahaan teknologi terkemuka kanthi luwih saka 1,500 klien biasa ing 80 negara, nggunakake luwih saka 85,000 sistem menyang basis pelanggan sing beda-beda sajrone 12 taun bisnis. Kita nawakake solusi komputasi, tampilan, jaringan lan koleksi data sing berkualitas tinggi lan inovatif kanggo sektor pasar sing dipasang, industri, lan digital.
US
sales@assured-systems.com
Sales: +1 347 719 4508 Dhukungan: +1 347 719 4508
1309 Coffeen Ave Ste 1200 Sheridan WY 82801 USA
EMEA
sales@assured-systems.com
Sales: +44 (0)1785 879 050 Dhukungan: +44 (0)1785 879 050
Unit A5 Douglas Park Stone Business Park Stone ST15 0YJ Inggris Raya
Nomer PPN: 120 9546 28 Nomer Registrasi Bisnis: 07699660

www.assured-systems.com | sales@assured-systems.com

Kaca 28/28

Dokumen / Sumber Daya

ASSURED 104-COM-8S, 104-COM-4S 8/4 Port Papan Komunikasi Serial [pdf] Manual pangguna
104-COM-8S, 104-COM-4S, 104-COM-8S 104-COM-4S 8 4 Papan Komunikasi Serial Port, 104-COM-8S 104-COM-4S, 8 4 Papan Komunikasi Serial Port, Papan Komunikasi Serial, Papan Komunikasi, Papan

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *