Product Usage Instructions

Wiring and Programming the Panel

It is recommended that an experienced alarm installer programs the panel to ensure proper performance. Avoid routing wiring over the circuit board.

New Feature – MiNi/MQ Series Communicators:

The status of the panel can now be retrieved from Open/Close \reports in addition to the status PGM. Wiring the white wire and programming of the status PGM are optional, required only if Open/Close reporting is disabled.

Open/Close Reporting:

Open/Close reporting must be enabled during the initial pairing procedure for proper functionality.

Events Reporting and Remote Control

For MN01, MN02, and MiNi communicator series, wiring is needed for events reporting and remote control via keybus or key switch based on device support. For MQ03 communicator series, wiring is required for events reporting and remote control via keybus or key switch based on device support.

Ringer MN01-RNGR Integration

Wiring the MN01, MN02, and MiNi Series with Ringer MN01-RNGR to Interlogix NX-8 for UDL.

Programming via Keypad

To program the Interlogix NX-6V2 Alarm Panel via the keypad, follow the steps provided in the user manual. Enable Contact ID reporting and configure the system ready settings.

Contact ID Reporting:

Follow the keypad entry instructions provided to set up Contact ID reporting.

All Toggle Options:

Ensure all toggle options are enabled for proper functionality.

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For MiNi/MQ Series Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialer. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. Wiring the white wire is necessary only if the Open/Close reporting is disabled.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring

Wiring the MN01, MN02 and MiNi communicator series for events reporting and remote control via key bus*

Interlogix-NX-6V2_-MN-MQ-Series_-Cellular_-Communicators_-and-Programming_-The-Panel-fig (1)

*Remote control via the keybus allows you to arm/disarm or arm in stay multiple partitions, bypass zones and get the status of the zones.

Wiring the MQ03 communicator series for events reporting and remote control via keybus*

Interlogix-NX-6V2_-MN-MQ-Series_-Cellular_-Communicators_-and-Programming_-The-Panel-fig (2)

*Remote control via the keybus allows you to arm/disarm or arm in stay multiple partitions, bypass zones and get thestatus of the zones.

Wiring the MN01, MN02 and MiNi communicator series for events reporting and remote control via Keyswitch*

Interlogix-NX-6V2_-MN-MQ-Series_-Cellular_-Communicators_-and-Programming_-The-Panel-fig (3)

*The optional key switch configuration can be used for M2M communicators that do not support keybus functionality. You do not need to configure this option if your device supports remote control via the keybus.

Wiring the MQ03 communicator series for events reporting and remote control via Keyswitch*Interlogix-NX-6V2_-MN-MQ-Series_-Cellular_-Communicators_-and-Programming_-The-Panel-fig (4)

*The optional keyswitch configuration can be used for M2M communicators that do not support keybus functionality. You do not need to configure this option if your device supports remote control via the keybus.

Wiring the MN01, MN02 and MiNi Series with Ringer MN01-RNGR to Interlogix NX-8 for UDLInterlogix-NX-6V2_-MN-MQ-Series_-Cellular_-Communicators_-and-Programming_-The-Panel-fig (5)

Programming the Interlogix

Programming the Interlogix NX-6V2 Alarm Panel via the Keypad

Enable Contact ID reporting:

Display Keypad Entry Action Description
System ready *89713 Enter programming mode
Enter device address 00# To go to edit main menu
Enter location 0# To configure Phone 1
Loc# 0 Seg#1 15*, 1*, 2*, 3*,

4*, 5*, 6*, #

Set value 123456 and DTMF dialing for this number (Seg#1 = 15). Press #

to go back (123456 is just an example)

Enter location 1# To configure Phone 1 account code
Loc# 1 Seg#1 1*, 2*, 3*, 4*, # Type the desired account code (1234 is just an example). # to go back.
Enter location 2# To configure Phone 1 communicator format
Loc# 2 Seg# 1 13* Set the value to 13 which corresponds to “Ademco Contact ID”. * to save

and go back.

Enter location 4# To go to “Phone 1 events reported” toggle menu.
Loc# 4 Seg# 1 12345678* All toggle options should be enabled. * to save and go to next menu.
Loc# 4 Seg# 2 12345678* All toggle options should be enabled. * to save and go back
Enter location 5# To go to “Phone 1 partitions reported” toggle menu
Loc# 5 Seg# 1 1* Enable option 1 to enable report events from partition 1 to phone number

1. * to save and go back.

Enter location 23# To go to “Partition features” menu
 

Loc# 23 Seg# 1

 

*, *, 1, *, #

Press * twice to go to section 3 toggle options menu. Enable option 1 (to enable “Open/Close reporting”), press * to save and then # to go back to

the main menu.

Enter location Exit, Exit Press “Exit” twice to exit programming mode.

Program Keyswitch zone and output:

Display Keypad Entry Action Description
System ready *89713 Enter programming mode
Enter device address 00# To go to edit main menu
Enter location 25# To go to “Zone 1-8 zone type” menu
Loc# 25 Seg# 1 11, *, # To configure Zone1 type as keyswitch, * to save and go to the next section,

# to go back to the main menu.

Enter location 45 # To go to “Auxiliary output 1 to 4 partition selection” toggle menu.
Loc# 45 Seg# 1 1, *, # Enable option 1 to assign events from partition 1 to impact output 1. Press

* to save and go to next section, then # to go back to the main menu.

Enter location 47# To go to “Auxiliary output 1 event and times” menu.
Loc# 47 Seg# 1 21* Enter 21 to assign “Armed status” event to PGM 1. Press * to save and go

to the next section.

Loc# 47 Seg# 2 0* Enter 0 to set the output to follow the event (without delay). Press * to save and go back to the main menu.
Enter location Exit, Exit Press “Exit” twice to exit programming mode.

Programming the GE Interlogix NX-6V2 Alarm Panel via the Keypad for remote Upload/Download (UDL)

Program the Panel for Upload/Download (UDL):

Display Keypad Entry Action Description
System ready *89713 Enter programming mode.
Enter device address 00# To go to main edit menu.
Enter location 19# Start configuring “Download Access Code”. By default, it is “84800000”.
 

Loc#19 Seg#

8, 4, 8, 0, 0, 0,

0, 0, #

Set the Download Access Code to its default value. Press # to save and

go back. IMORTANT! This code should match the one set in the “DL900” software.

Enter location 20# To go to “Number of rings to answer” menu.
Loc#20 Seg# 1# Set number of rings to answer to 1. Press # to save and go back.
Enter location 21# Go to “Download control” toggle menu.
Loc#21 Seg# 1, 2, 3, 8, # All of these (1,2,3,8) should be OFF in order to disable “AMD” and “Call

back”.

Enter location Exit, Exit Press “Exit” twice to exit programming mode.

FAQ

  • Q: Do I need a professional to program the panel?
    • A: It is advised that an experienced alarm installer programs the panel to ensure proper performance.
  • Q: Is wiring over the circuit board recommended?
    • A: No, avoid routing any wiring over the circuit board for \safety and performance reasons.