Safety Notes

Note: To ensure reasonable consistency of operation, please read this manual carefully. Any damages caused by the non-observance of this manual or any unauthorized modification to this product are not subject to warranty.

  1.  Maintain a 50CM space at the back of the fixture for dissipate heat.
  2. . This lamp is used for indoor lighting. When lamp works, lamp tube at high temperature.
  3.  Make sure the voltage and frequency of power supply match the power require of this devise.
  4.  Please do not operate the equipment in the condition of wire damage or wear.
  5.  Do not remove any part of the equipment during the use of the fixture.
  6.  Any unauthorized modification to this product is not subject to warranty.

Display panel and key button definition

  • Menu key: Select the function
  • Up key: parameter arguments Down key:
  • parameter decline
  • Confirm key: Determine and save

Menu function

Press the menu; key up or down to modify the function parameters and confirm with enter, which saves the current function and parameters (power memory after saving).

Menu function table:

A00

1

A512 Modify the address code up or down (A001~A 512) to confirm that the key is

saved, with the default of A001.

CH0 3 CH24 Switch CH03, CH09, CH24 three channels up or down, confirm the key save,

default CH09.

FF0 0 FF99 Gradient, up or down to modify the gradient speed (FF00~ FF99), confirm that

the key is saved, the default FF10.

EE0 0 EE99 Pulse change, up or down to modify the pulse change speed (EE00~ EE99),

confirm the key to save, the default EE10.

P00

0

P241 There are 242 built-in effects (P000~P241), switch the built-in effects up or

down, confirm the key save, and the default P000 jump.

S00

0

S255 Modify the built-in effect running speed (S 000-S 255) and confirm that the key is

saved, with the default S010.

Sou d Soud Sound control mode.
R25

5

R000 Modify the red bead brightness (R 000-R255) up or down, and confirm that the

key is saved, with the default R 255.

G25 5 G000 Modify the green bead brightness (G000~ G255) to confirm that the key is

saved, with the default G255.

B25

5

B000 Modify the blue bead brightness up or down (B000~ B255), and confirm that the

key is saved, with the default B255.

T00

0

Display temperature, such as T045 indicates the current lamp temperature of

45℃; 10K thermistor is not installed, display T000.

Master-slave control

Two or more of the same fixtures are connected by DMX three-core signal line, the fixture is set to any address code of A001~A512, any one is set as the master, and the other fixture are the slaves.
Pay attention: Only one host can be set for a group of fixtures. If there are more than one host, all fixtures will flash randomly and out of sync.

Factory setting

When any address code is A001~A512, press the menu button for 3 seconds to enter the factory setting. The factory settings are mainly the functions of the output power of each lamp, the fan setting mode, setting the temperature protection point, and sending the parameters. Any mode set by the factory, press the menu button for 3 seconds to exit.

Factory setting List:

R 255   R032 Modify the red current (R032-R 255) up or down to confirm that the key is saved

with the default R240.

G 255   G032 Modify the green current up or down (G 032-G255) to confirm that the key

is saved, with the default G240.

B 255   B032 Modify the blue current up or down (B 032-B255), and confirm that the key

is saved with the default B240.

FAN0   FAN1 Fan setting: FAN0 lights on to start the fan, FAN1 reaches the set

temperature protection points to start the fan, and confirm the key to save.

T040   T105 Set the temperature protection point, modify the parameters up or down (40℃ ~105℃) and press OK to save, with the default T060.
 

S end

 

 

 

S end

Send the parameters set by the local factory up or down to all other fixture connected by three-core signal lines; confirm that the transmission parameters exit by the

dish menu key for 3 seconds and cancel the transmission by the confirmation key.

DMX512 console

After power on, all fixture address codes are set, all fixtures are connected to the DMX512 console in parallel with a three-core signal line, and the address code will stop flashing, indicating that the DMX512 console signal has been sent to the lamp, and the relevant functions are controlled by the DMX512 console according to each channel description.

CH03-channel Description:

chan

nel

Channel

value

basic function
1 000-255 Red dimming
2 000-255 Green dimming
3 000-255 Blue dimming

CH09 channel description:

chan

nel

Channel

value

basic function
1 000-255 Total dimming
2 000-255 Red dimming
3 000-255 Green dimming
4 000-255 Blue lamp beads for linear dimming
5 000-255 Strobe
6 000-255 Chase Mode 1 (Different chases every 2 DMX values)
7 000-255 Chase Mode 2 (Different chases every 2 DMX values)
8 000-255 Chase Mode 3 (Different chases every 2 DMX values)
9 000-255 Chase Speed

Description of the Ch24 channel:

cha

nnel

Channel

value

basic function
1 000-255 Red Section 1
2 000-255 Green Section 1
3 000-255 Blue Section 1
……
22 000-255 Red Section 8
23 000-255 Green Section 8
24 000-255 Blue Section 8

Technical parameters

  • Voltage: AC100~240V 50 / 60HZ Power:
  • 240W
  • LED: x960,0503-RGBcolor LED
  • Control mode: DMX512, Auto, master, sound control.
  • Channel: CH03, CH09, and CH24
  • 8 independent LED control sections.
  • Strobe frequency: 1~30HZ
  • Housing: Metal, black
  • Connection mode: DMX512 input / output
  • IP level: IP20