Field Controls UV 16

Field Controls UV-16/120 UV-Aire In Duct Air Purifier

Käyttöopas

1. Johdanto ja tuotekatsausview

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed to improve indoor air quality by utilizing ultraviolet (UV-C) light technology. This device is installed directly into your HVAC system's ductwork, where it neutralizes airborne contaminants such as bacteria, viruses, mold spores, and allergens as air passes through. This manual provides essential information for the safe and effective installation, operation, and maintenance of your UV-Aire system.

Field Controls UV-16/120 UV-Aire In Duct Air Purifier unit with a glowing UV lamp extending from the side.

This image displays the Field Controls UV-16/120 UV-Aire In Duct Air Purifier, a compact white unit designed for installation within HVAC ductwork. A blue glowing UV lamp is visible extending from the right side of the main housing, indicating its air purification function.

2. Turvallisuustiedot

Lue kaikki turvallisuusohjeet huolellisesti ennen asennusta ja käyttöä. Näiden ohjeiden noudattamatta jättäminen voi aiheuttaa sähköiskun, tulipalon tai vakavan vamman.

3. Pakkauksen sisältö

Verify that all components are present and undamaged before beginning installation. If any items are missing or damaged, contact your supplier immediately.

4. Asennus ja asennus

The UV-16/120 UV-Aire unit is designed for installation within the return or supply air duct of your HVAC system. Proper placement is crucial for effective air purification.

  1. Virran katkaisu: Turn off all power to the HVAC system at the main electrical panel or circuit breaker. Verify power is off using a voltage testaaja.
  2. Valitse asennuspaikka: Choose a location in the ductwork that allows for sufficient airflow around the UV lamp and provides easy access for future maintenance (e.g., bulb replacement). Ensure there is at least 16 inches of clear space for the lamp.
  3. Leikkausaukko: Using the provided template (if applicable) or the unit's dimensions, carefully cut an opening in the ductwork for the main housing of the UV-Aire unit. Ensure the opening is clean and free of sharp edges.
  4. Asenna yksikkö: Insert the UV-Aire unit into the cut opening. Secure the unit to the ductwork using the provided mounting screws. Ensure a tight seal to prevent air leakage.
  5. Sähköliitäntä: Connect the unit's power cord to a dedicated 120 Volt power source, typically wired into the HVAC system's control circuit so it operates when the fan is running. Follow all local electrical codes. The unit features a safety disconnect for added protection.
  6. Asenna UV Lamp: Jos lamp is not pre-installed, carefully insert the UV-C lamp into its receptacle on the unit. Ensure it is securely seated. Avoid touching the glass portion of the lamp paljain käsin.
  7. Palauta virta: Once installation is complete and all connections are secure, restore power to the HVAC system.

5. Käyttöohjeet

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed for continuous operation when your HVAC system's fan is running. It does not require daily user interaction.

6. Huolto

Regular maintenance ensures the continued effectiveness and longevity of your UV-Aire system.

7. Vianmääritys

If your UV-Aire system is not functioning as expected, refer to the following common issues and solutions:

OngelmaMahdollinen syyRatkaisu
UV lamp ei palaLaitteessa ei ole virtaaCheck circuit breaker. Ensure HVAC fan is running if wired to fan circuit.
UV lamp ei palaLamp has reached end of lifeVaihda UV lamp (katso Huolto-osio).
UV lamp ei palaViallinen painolastiContact a qualified technician for inspection and replacement of the ballast. (Note: Some users have reported ballast failure after extended use.)
Reduced air purification effectivenessLamp is old or dirtyReplace or clean the UV lamp.
Yksikkö pitää epätavallista ääntäLoose mounting or internal component issueEnsure unit is securely mounted. If noise persists, contact a qualified technician.

If the problem persists after attempting these solutions, contact Field Controls customer support or a qualified HVAC professional.

8. Tekniset tiedot

Key technical specifications for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier:

9. Takuutiedot

Specific warranty terms for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier are typically provided at the time of purchase or can be obtained directly from Field Controls or your authorized dealer. It is recommended to retain your proof of purchase for warranty claims.

Extended protection plans may be available from third-party providers at the point of sale. These plans are separate from the manufacturer's warranty.

10. Tukea

For technical assistance, replacement parts, or further inquiries regarding your Field Controls UV-16/120 UV-Aire In Duct Air Purifier, please contact:

When contacting support, please have your product model number (UV 16) and date of purchase readily available.

Aiheeseen liittyvät asiakirjat - UV 16

Preview UV-AIRE™ UV-500C -ilmanpuhdistusjärjestelmä: Käyttöopas ja tekniset tiedot
Tämä asiakirja sisältää kattavat ohjeet Field Controlsin UV-AIRE™ UV-500C -ilmanpuhdistusjärjestelmälle. Se sisältää asennusohjeet, käyttöohjeet, huolto-ohjelmat ja vaihto-ohjeet.amps and filters, and warranty information. Learn how to effectively use the system to improve indoor air quality by removing airborne contaminants like mold, bacteria, viruses, allergens, dust, pollen, and VOCs.
Preview Field Controls Duo-2000 -fotokatalyyttisen ilmanpuhdistimen asennusohje
Kattava asennus-, huolto- ja vianmääritysopas Field Controls Duo-2000 -fotokatalyyttiselle ilmanpuhdistimelle, joka on suunniteltu steriloimaan ja puhdistamaan ilmaa asuinrakennusten LVI-järjestelmissä UVC-valon ja fotokatalyyttisen tekniikan avulla.
Preview Trio Plus Air Purifier User Manual | Field Controls
Comprehensive user manual for the Field Controls Trio Plus air purifier, covering safety, operation, maintenance, filter replacement, troubleshooting, and specifications.
Preview Field Controls Trio Plus Air Purifier User Manual
Comprehensive user manual for the Field Controls Trio Plus Air Purifier, covering setup, operation, maintenance, safety guidelines, and troubleshooting for optimal indoor air quality.
Preview Field Controls S2000 & S2020 Power Humidifier: Installation & Owner Manual
Comprehensive installation instructions and owner's manual for Field Controls S2000 (120VAC) and S2020 (240VAC) electronic steam power humidifiers. Learn how to install, operate, and maintain your unit for optimal performance in forced air systems.
Preview Field Controls CAS-34U Combustion Air System Installation Guide
Installation and operation guide for the Field Controls CAS-34U Combustion Air System. Learn about specifications, sizing, setup, wiring, maintenance, and troubleshooting for oil and gas appliances.