ZEVF200VW Variable White Fresnel with Zoom
“
Specifications
- Product: Variable White Fresnel with Manual Zoom F200VW
- Input Voltage Range: 100~240 VAC, 50/60 Hz
- Maximum Power Linking: 8A
- Control Options: DMX
Product Usage Instructions
Safety Instructions
Power Input & Power Linking: Ensure input
voltage is within the specified range. Do not exceed 8A power
linking.
Product Installation: Mount securely in various
orientations using the correct mounting bracket. Always use a
safety chain when mounting overhead.
Fuse Replacement: Only replace the fuse with
the same type and rating. Follow the steps provided in the manual
for safe replacement.
Control Board Operation
DMX Address Setting: Set the DMX address
according to your setup requirements.
DMX Modes Setting: Choose the appropriate DMX
mode for your lighting control.
Manual Colour Setting: Adjust the color
settings manually as needed.
Master/Slave Setting: Configure master/slave
settings for synchronized operation with multiple units.
FAQ
Q: What should I do if the device exceeds the maximum power
linking?
A: Avoid exceeding the specified power linking limit to prevent
damage to the device or electrical hazards.
Q: How do I know which DMX mode to select?
A: Refer to the DMX modes setting section in the manual to
choose the mode that best suits your lighting setup.
“`
Variable White Fresnel with Manual Zoom
F200VW USER MANUAL
For safety, please read this user manual carefully before initial use.
Event Lighting reserves the right to revise the manual at any time. Information and specifications within this manual are subject to change without notice. Event Lighting assumes no liability or responsibility for any errors or omissions.
Ver 3.1 (08.07.2025)
CONTENTS
Safety Instructions ………………………………………………………………………………. 2
– Power input & power Linking………………………………………………………………………….. 2
Product Installation ……………………………………………………………………………… 2
– Fuse replacement …………………………………………………………………………………………. 2
Diagrams ……………………………………………………………………………………………. 3
– Lux chart ………………………………………………………………………………………………………….3 – Dimensions…………………………………………………………………………………………………… 4
Control Board Operation………………………………………………………………………. 5
– DMX address setting……………………………………………………………………………………… 5 – DMX modes setting……………………………………………………………………………………….. 5 – Manual colour setting…………………………………………………………………………………….. 6 – Master/slave setting ………………………………………………………………………………………. 6
DMX chart ………………………………………………………………………………………..7-8 Technical specifications………………………………………………………………………9 Warranty…………………………………………………………………………………………….. 9
1
Safety Instructions
WARNING
· Do not open this device, there is no user-serviceable parts inside. Risk of electric shock. · Do not look at the light source when the device is on. · CAUTION: This unit’s housing may be hot during and after operation. · Install this device in a location with adequate ventilation, at least 20 inch (50 cm) from adjacent surfaces. · Do not leave any flammable material within 50 cm of this unit while operating or connected to power. · Use a safety chain when mounting this device overhead. · Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity may affect it. · Do not operate this device if the housing, lenses, or cables appear damaged. · Do not connect this device to a dimmer or rheostat. · ONLY connect this device to a grounded and protected circuit. · ONLY use the hanging bracket to carry this device. · In case of a serious operating problem, stop using immediately. · The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher temperatures.
Power Input & Power Linking
This device has an auto-switching power supply work with input voltage range of 100~240 VAC, 50/60 Hz. Link up to the maximum 8A. DO NOT exceed this number.
Product Installation
This device can be mounted in many orientations provided each individual device is secured by the use of correct mounting bracket.
Use a safety chain when mounting this device overhead.
Fuse Replacement
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. Before replacing the fuse, unplug mains lead. Procedure: Step 1: Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing (anticlockwise). Step 2: Remove the old fuse from the fuse holder. Step 3: Install the new fuse in the fuse holder. Step 4: Replace the fuse holder in the housing and fix it.
2
Lux Chart
3
Dimensions
4
CONTROL BOARD OPERATION
Display DMX Add DMX Cha DMXLoss UserDMX
Manual
Mas/Sla Wireless
Reset Update
Options / Values <001> – <508> <01>, <1U><02>, <05>,<07><User> <Hold><Blacko><Manual> CH:<01> End Preset <StraW> <WarmW> <White> <CoolW> <Steel> Finetune <Straw> <Straw+> <Stra++> <- -Warm> <-WarmW> <WarmW> <WarmW+> <Warm++> <- -Whit><-White> <White> <White+> <Whit++> <- -Cool> <-CoolW> <CoolW> <CoolW+> <Cool++> <- -Stee> <-Steel> <Steel> Dimmer <000> – <100> < Sla> / <Mas>
<ON><OFF> <EL Mode> <W-DMX_R> <W-DMX_T> <N> / <Y>
<N>/ <Y> <START>
Function To set DMX address To set DMX channel modes Select mode when DMX loss Edit a user DMX mode To select colour from 5 preset colour temperature modes
To select colour from 21 fine tune colour temperature modes
To set dimming intensity To set Master/Slave modes You need to install WDMX module inside the fixture first and then receive the DMX signal from the transmitter attached to the console by setting this on
To reset factory default setting Select to update firmware Use this fixture to update another fixture’s software
DMX Addressing: After selecting the “DMX Add” press “Enter”, use “Up” and “Down” buttons to select the desired DMX address, press “Enter” to save new setting
DMX Modes After selecting the “DMX Cha” press “Enter”, use “Up” and “Down” buttons to select the desired DMX mode, press “Enter” to save new setting
DMX Loss Give users the ability to set what they want as the DMX Loss.
– By Standard ,out of the box, if in DMX mode and no signal = hold along with, if receiving DMX signal and loss = hold last signal – Give users the ability to select, call on the menu DMX Loss then let users choose Hold (hold last signal), Blackout, Manual (last manual colour) or Auto (last Auto show selected) –
5
User DMX Under this item, you can essentially pick a channel and assign a function of the DMX mode. So for example, once ‘User DMX’ is selected, you can click through the channels so by default it may be the max amount of channels allocated, then you can re-arrange as you please and once you are finish, put an option to have the last channel ‘End’ so that it stops. Say you want 10 channels, the 11th channel would be End. making it a 10 channel user mode.Then to select this mode, under DMX Channel mode it would just be ‘User’.
Manual After entering “Manual” mode, use “Up” and “Down” buttons to select the colour from preset colour group and fine tune group, set intensity from 000 to 255, press “Enter” to save new setting Master/Slave Set the master fixture to one of the standalone operating modes. Set the slave, enter “Mas/Sla” mode, set to “Slave”, press “Enter” to save the setting. Firmware update Use fixture A to update fixture B’s firmware
– Set fixture A to “Update” mode, select “Y” then select “START” – Link fixture A and fixture B with DMX cable, then power up fixture B – Press “Enter” on fixture A, fixture B’s firmware will be copied from fixture A. *Ensure that fixture A and B are of the same type, otherwise damage may occur. * Only fixture A and B should be in the DMX chain when updating firmware.
6
Fade Mode
DMX Chart
1 channels Mode
Channel 1
Value 000 – 255
Function Dimmer & Colour temperature
1U channels Mode
Channel 1U
Value 000 – 255
2 channels Mode
Channel 1 2
Value 000 – 255 000 – 255
Function Dimmer (dim the preset color selected in Menu)
Function Dimmer 0% ~ 100% Warm white to cool white
7
5 channels Mode
Channel 1 2 3
4
5
Value 000 – 255 000 – 255 000 – 255 000 – 015 016 – 119 120 – 127 128 – 183 184 – 191 192 – 247 248 – 255 000 – 050 051 – 101 102 – 152 153 – 203 204- 255
Function Master dimmer coarse: 0% ~ 100% Master dimmer fine: 0% ~ 100% Warm white to cool white No function(Shutter on) Strobe slow to fast (1-25Hz) Shutter on Strobe random slow to fast Shutter on Strobe audio sensitivity low to high Shutter on Standard Stage TV Architect Theater
7 channels Mode
Channel 1 2 3 4
5
6 7
Value 000 – 255 000 – 255 000 – 255 000-255 000 – 015 016 – 119 120 – 127 128 – 183 184 – 191 192 – 247 248 – 255 000 – 009 010 – 255 000 – 050 051 – 101 102 – 152 153 – 203 204- 255
Function Master dimmer coarse: 0% ~ 100% Master dimmer fine: 0% ~ 100% Warm White Cool White No function(Shutter on) Strobe slow to fast (1-25Hz) Shutter on Strobe random slow to fast Shutter on Strobe audio sensitivity low to high Shutter on No function Preset Colours (Warm->Cold) Standard Stage TV Architect Theater
8
TECHNICAL SPECIFICATIONS
Power Power Supply: 100~240V AC, 50/60 Hz Power Consumption: 120W Power Connection: Seetronic in / out
Photometrics Light Source: 1 x 100W*2 cool white 6500K and warm white 2700K COB LED CRI: 95+ Beam Angle: 20° – 53° Field Angle: 34° – 70° Output: 3550 lux @3M at 20°, 1025 lux @3M at 53° Lens: 80mm Planconvex lens PWM: 1,200Hz LED Lifespan: 50,000 hours
Effects Dimming: 16-bit 0 – 100% Strobe: 1 25 Hz Zoom: Manual Zoom 20° to 53° Barn Door: Included Gel Clip: Included
Control Operational Modes: Manual, Master / Slave & DMX ,WDMX, RDM Display: 4-button LCD control panel DMX Protocol: DMX512 DMX Channel Mode: 1 / 1U / 2 / 5 / 7 / User DMX Interface: 5-pin XLR (Optional 3-pin XLR)
Housing Housing Materials: Die- cast Aluminum Housing Housing Finishing: Matte Black Cooling: Fanless Cooling with Temperature Protection Net Weight: 3.2 kg Dimension: 217.5 X 167 X 200mm
9
Documents / Resources
![]() |
EVENT LIGHTING ZEVF200VW Variable White Fresnel with Zoom [pdf] User Manual ZEVF200VW Variable White Fresnel with Zoom, ZEVF200VW, Variable White Fresnel with Zoom, White Fresnel with Zoom, Fresnel with Zoom |