EPH CONTROLS -logoInstallation Instructions
For use in normal environments.EPH CONTROLS R27 RF 2 Zone RF Programmer-

R27-RF – 2 Zone RF Programmer
EPH CONTROLS -icon1

R27-RF 2 Zone RF Programmer

Important: Keep this document
This 2 zone RF programmer is designed to provide ON/OFF control for 2 zones, with the value added application of in built frost protection.

EPH CONTROLS -icon CAUTION! Installation and connection should only be carried out by a qualified person and in accordance with national wiring regulations.

  • Before commencing any work on the electrical connections, you must first disconnect the programmer from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the programmer. Disconnect from mains supply in the event of any damage to any buttons.
  • There are parts that carry mains voltage behind the cover. The programmer must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
  • If the programmer is used in a way not specified by the manufacturer, its safety may be impaired.
  • Ensure that this wireless enabled programmer is installed 1 metre from any metalic object, television, radio or wireless internet transmitter.
  • Prior to setting the programmer, it is neccessary to complete all required settings described in this section.
  • Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.

This programmer can be mounted in the following ways:

  1. Directly wall mounted
  2. Mounted to a recessed conduit box

EPH CONTROLS R27 RF 2 Zone RF Programmer- fig1

EPH CONTROLS R27 RF 2 Zone RF Programmer- fig2

EPH CONTROLS -icon2 Factory default settings

Contacts: 230 Volt
Program: 5/2D
Backlight: On
Keypad: Unlocked
Frost Protection: Off
Clock type: 24 Hr Clock
Day-Light Saving

Specifications & wiring

Power Supply: 230 Vac
Ambient Temp: 0~35°C
Contact Rating: 250 Vac 3A(1A)
Program Memory
backup:
1 year
Battery: 3Vdc Lithium LIR 2032
Backlight: Blue
IP rating: IP20
Backplate: British System Standard
Pollution degree 2: Resistance to voltage surge 2000V
as per EN 60730
Automatic Action: Type 1.S
Software: Class A

EPH CONTROLS R27 RF 2 Zone RF Programmer- fig3

EPH CONTROLS -icon3 Setting the date and time

Lower the cover on the front of the programmer.
Move the selector switch to the CLOCK SET position.

Press the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to select the day. Press EPH CONTROLS -icon6
Press the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to select the month. Press EPH CONTROLS -icon6
Press the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to select the year. Press EPH CONTROLS -icon6
Press the EPH CONTROLS -icon4 orEPH CONTROLS -icon5 buttons to select the hour. Press EPH CONTROLS -icon6
Press the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to select the minute. Press EPH CONTROLS -icon6
Press the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to select 5/2D, 7D or 24H  Press EPH CONTROLS -icon6

Frost protection function

EPH CONTROLS -icon2 Off

Selectable range 5-20°C This function is set to protect pipes against freezing or to prevent low room temperature when the programmer is programmed to be OFF or is manually OFF.
Frost protection can be activated by following the procedure below. Move the selector switch to the RUN position.
Press both the EPH CONTROLS -icon4and EPH CONTROLS -icon5 buttons for 5 seconds, to enter selection mode.
Press either the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to to turn On or turn Off frost protection.
Press EPH CONTROLS -icon6 button to confirm
Press either the EPH CONTROLS -icon4 or EPH CONTROLS -icon5 buttons to increase or decrease the desired frost protection setpoint.
Press EPH CONTROLS -icon6 to select.
All zones will be switched ON in the event of room temperature falling below the frost protection setpoint.

Master reset

Lower the cover on the front of the programmer. There are four hinges holding the cover in place. Between the 3rd and 4th hinges there is a circular hole. Insert a ball point pen or similar object to master reset the programmer. After pressing the master reset button, the date and time will now need to be reprogrammed.

EPH CONTROLS -logoEPH Controls Ireland
technical@ephcontrols.com www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.co.uk www.ephcontrols.co.uk
20221107_R27-RF_InsIns_PK

Documents / Resources

EPH CONTROLS R27 VF 2 Zone Programmer [pdf] Instruction Manual
R27 VF 2 Zone Programmer, R27 VF 2, Zone Programmer, Programmer
EPH CONTROLS R27-VF 2 Zone Programmer [pdf] Instruction Manual
R27-VF, R27-VF 2 Zone Programmer, 2 Zone Programmer, Programmer
EPH CONTROLS R27-VF 2 Zone Programmer [pdf] Instruction Manual
R27-VF, R27-VF 2 Zone Programmer, 2 Zone Programmer, Programmer
EPH CONTROLS R27-VF 2 Zone Programmer [pdf] Instruction Manual
R27-VF 2 Zone Programmer, R27-VF, 2 Zone Programmer, Zone Programmer, Programmer

References

Leave a comment

Your email address will not be published. Required fields are marked *