Hilti KB-TZ2 Wedge Anchor

1/2" x 3"

Document Number: 2284815-03.2025

Installation Overview

The Hilti KB-TZ2 wedge anchor is designed for secure fastening in concrete and grout-filled CMU. Proper installation ensures optimal performance and safety. The following steps outline the recommended installation procedure.

Step 1: Hole Preparation

Drill a hole in the base material using the appropriate drill bit and depth. Ensure the hole is clean and free of debris.

  • Drill Bit Diameter (d₀): 1/2 inch. Use carbide-tipped masonry drill bits complying with ANSI B212.15.1994.
  • Hole Cleaning: Use dust removal systems (DRS) or compressed air/brush to clean the hole thoroughly. This is crucial for achieving the specified embedment depth (h₀).
  • Hole Depth: The minimum hole depth in the base material (h₀) is 2¼ inches. The effective embedment depth (h_ef) is 1½ inches, and the nominal embedment depth (h_nom) is 2 inches. Ensure drilling depth accounts for any debris remaining in the hole to achieve the required h₀.
  • Drilling Angle: Drill at a 90° angle to the surface.

Supported Drill Bits and Systems:

  • Hollow Drill Bit (HDB)
  • Dust Removal Systems (DRS)
  • AT-System: SIW 6AT-A22 + SI AT-A22, SIW 4AT-22 + SI-AT-22, SIW 6AT-22 + SI-AT-22
  • Diamond Core Bit

Step 2: Anchor Insertion

Insert the anchor into the prepared hole. Ensure it is seated correctly. If necessary, gently tap the anchor head with a hammer to fully seat it.

Step 3: Tightening the Anchor

Place the fixture over the anchor and thread the nut onto the anchor stud. Tighten the nut using the specified wrench size (WS) until the anchor is fully set.

  • Installation Torque (T_inst): For concrete, the installation torque is 50 ft-lb. For grout-filled CMU, it is 25 ft-lb.
  • AT-System: The AT-System is not applicable for grout-filled CMU and wood fastening applications.

Specifications Table

SymbolSymbol DescriptionUnitsAnchor Diameter [inch]
HDBHollow Drill Bit✔️
DRSDust Removal Systems✔️
AT-SystemSIW 6AT-A22 + SI AT-A22✔️
SIW 4AT-22 + SI-AT-22✔️
SIW 6AT-22 + SI-AT-22✔️
Diamond Core Bit✔️
d₀Drill Bit Diameter[inch]1/2
h_efEffective Embedment Depth[inch]
h_nomNominal Embedment Depth[inch]2
h₀Minimum Hole Depth in Base Material[inch]
T_inst, concreteInstallation Torque Concrete (carbon steel)[ft-lb]50
T_inst, grout filled CMUInstallation Torque Grout-Filled CMU (carbon steel)[ft-lb]25
d_fixFixture Hole Diameter[inch]9/16
WSWrench Size[inch]3/4

Important Notes

Use only carbide-tipped masonry drill bits complying with ANSI B212.15.1994.

For steps 1a or 1b, ensure the drill depth is sufficient to accommodate any debris remaining in the hole to achieve the required h₀.

Note: The AT-System is not applicable for grout-filled CMU and wood fastening applications.

Models: SIW 6AT-A22, SI AT-A22, SIW 4AT-22, SI-AT-22, SIW 6AT-22, KB-TZ2 Hex Nut Concrete Wedge Anchor, KB-TZ2, Hex Nut Concrete Wedge Anchor, Concrete Wedge Anchor, Wedge Anchor

PDF preview unavailable. Download the PDF instead.

PUB 5545760 000 Adobe PDF Library 17.0 Adobe InDesign 20.2 (Macintosh)

Related Documents

Preview Hilti KB-TZ2 Anchors: Technical Specifications and Installation Guide
Detailed technical specifications, installation instructions, and performance data for Hilti KB-TZ2, KB-TZ2 SS304, and KB-TZ2 SS316 anchors, including drill bit sizes, embedment depths, and torque values.
Preview Hilti KB-TZ2 Anchors Installation Guide and Specifications
Comprehensive guide for Hilti KB-TZ2, KB-TZ2 SS304, and KB-TZ2 SS316 anchors, detailing installation steps, torque settings, and dimensions for various base materials and anchor sizes.
Preview HILTI KB1 Anchor System Technical Specifications and Installation Guide
Detailed technical specifications, installation steps, and anchor parameters for the HILTI KB1 anchor system, including dimensions, embedment depths, and installation torques for various base materials.
Preview Hilti HST3 and HST3-R M24 Wedge Anchor Installation Guide
Comprehensive guide for installing Hilti HST3 and HST3-R M24 wedge anchors, covering drilling, anchor insertion, and final torque specifications for secure concrete fastening.
Preview Hilti HVU2 Operating Instructions and Technical Specifications
Comprehensive guide to the Hilti HVU2 anchor system, including installation, technical data, and compatibility information. Learn about hammer drilling, hollow drill bits, and diamond coring applications.
Preview Hilti HIT-HY 170: Universal Adhesive Anchoring System
Discover the Hilti HIT-HY 170, a high-performance universal adhesive anchoring system designed for reliable and versatile fixing in concrete and various masonry types. Learn about its applications, safety, and technical specifications.
Preview Hilti HDA-T/-TF/-TR M10/M12 Anchor Installation and Specifications
Comprehensive guide for installing Hilti HDA-T, HDA-TF, and HDA-TR concrete anchors (M10 and M12 sizes). Includes detailed specifications, installation steps, accessory compatibility, and minimum clearance requirements for safe and effective fastening.
Preview Hilti HST4-R/HST4 Expansion Anchor: European Technical Assessment ETA-21/0878
Detailed European Technical Assessment (ETA-21/0878) for Hilti HST4-R and HST4 expansion anchors. Covers technical specifications, performance data, intended use, and installation for torque-controlled concrete anchoring.