- Product Name: E-72P Series Universal Advanced Controller
- Dimensions: 72×72 mm
- Inputs: T/C, R/T, mV, mA
- Outputs: Relay, SSR, Analog (mA and V)
- Operating Voltage: 85-265 V AC / 85-375 V DC
- Communication: RS-485
Product Usage Instructions
1. Unboxing and Inspection
Upon receiving the package, check that it contains the
controller, mounting clamps, user manual, and guarantee
certificate. Contact the vendor if any items are missing or there
are visible defects.
2. Installation
Install the controller in a panel in an industrial environment.
Ensure that the installation and configuration are done by a
qualified person in instrumentation.
3. Cleaning and Maintenance
Avoid using alcohol or solvents to clean the controller. Use a
clean cloth soaked in water to gently wipe the outer surface. Keep
the unit away from flammable gases.
4. Display and Programming
The controller features two 4-digit displays that can show set
and measured values. Inputs can be easily programmed for different
control forms.
Frequently Asked Questions (FAQ)
Q: What are the dimensions of the E-72P Series controller?
A: The controller dimensions are 72×72 mm.
Q: What inputs are supported by the controller?
A: The controller supports inputs such as T/C, R/T, mV, mA.
Q: How should I clean the controller?
A: Use a clean cloth soaked in water to gently wipe the outer
surface of the controller. Avoid using alcohol or solvents.
“`
KY-72P-0825-1
4. WARNINGS
E-72P Series
200.0 R1 Universal Advanced R2 Digital Controllers 200.0 PR MN Quick Start Guide
Elimko
Manufacturer / Technical Support
SET
Elimko Elektronik malat ve Kontrol Ltd. ti.
8. Cadde 21. Sokak No:16 Emek 06510 Ankara / TÜRKYE
72P
Telefon: + 90 312 212 64 50 Faks: + 90 312 212 41 43
www.elimko.com.tr · e-mail:elimko@elimko.com.tr
1. DESCRIPTION
E-72P Series universal process controllers are industrial devices at 72×72 mm IEC/TR 60668 dimensions designed using new generation microcontrollers with on/off, PID and other control forms, where inputs and outputs can be easily programmed by the user.
E-72P controller is designed for panel mounting and should be used in an industrial environment.
m The package of E-72P controller contans; Controller, 2 peces of mountng clamps, User manual and Guarantee certfcate.
m After openng the package, please check the contents wth the above lst. If the delvered product s wrong type, any tem s mssng or there are vsble defects, contact the vendor from whch you purchased the product.
m Before nstallng and operatng the controller, please read the user manual thoroughly.
m The nstallaton and confguraton of the controller must only be performed by a person qualfed n nstrumentaton.
m Keep the unt away from flamable gases, that could cause exploson.
m Do not use alcohol or other solvents to clean the controller. Use a clean cloth soaked n water tghtly squeezed to gently wpe the outer surface of the controller.
m It s not used n medcal applcatons.
EU DIRECTIVE COMPLIANCE
Low Voltage Drectve EN 61010-1 EMC Drectve EN 61326-1
K – Q TSE-ISO-EN
9000
TS EN ISO 9001 Quality Management System Certificate
In E-72P Series controllers, the set value and measured value can be displayed from -1999 to 9999 on two 4-digit displays; general purpose inputs (T/C, R/T, mV, mA) can be programmed.
5. TYPE CODING
2. DIMENSIONS and PANEL CUT-OUT
200.0 R1 R2 200.0 PR MN
Elimko
SET
72P
Elimko
Kontrol Edilmitir
2
TP
: E72P
SKALA :
GR :
ÇIKI :
SER NO : 22/10391
Elimko
Tel: +90 3122126450 Fax: +90 3122124143
TÜRKYE
-0.0 68 x 68 mm
+0.5 10 mm min.
35 mm min.
Panel Cut-Out and Minimum Spacing
3. CONNECTION DIAGRAM
E-72P Series Universal Advanced Controller
E-72P – W – X – Y – Z
Relay Outputs
None
0
1 relay (RL1)
1
2 relays (RL1, RL2)
2
1 SSR (SSR1)
3
1 SSR (SSR1) + 1 relay (RL2)
4
2 SSR (SSR1, SSR2)
5
Analog Outputs *
None
0
1 x 0-20 / 4-20 mA (AO1)
1
2 x 0-20 / 4-20 mA (AO1, AO2) *
2
1 x 0-10 V DC (AO1)
3
2 x 0-10 V DC (AO1, AO2) *
4
1 x 0-20 / 4-20 mA (AO1) + 1 x 0-10 V DC (AO2)
5
Communication
None
0
RS-485 **
1
Operating Voltage
85-265 V AC / 85-375 V DC
0
20-60 V AC / 20-60 V DC
1
* Analog outputs are isolated from each other. ** When E-72P Series devices are ordered with communication, the E-IB-11 USB-RS485 converter can be used for PC connection. There are various control and monitoring software provided by Elimko.
RL1
15
1
8
6. TECHNICAL SPECIFICATIONS
Analog Outputs AO1
SSR1 AO2
Relay and SSR Outputs
Thermocouple / miliVolt 0-20 mA / 4-20 mA
Resistance Thermometer 2-Wire Transmitter Volt
Operating voltage suitable for the device type shall be applied.
2 RL2
3 4
5
6
7
Power Supply SSR2
RS-485 GND TRX + TRX –
9
16
10
17
Analog Inputs
11
18
12
19
13
20
14
21
1st and 2nd control outputs can be selected as either Relay (RL1, RL2) or SSR (SSR1, SSR2).
Analog output (AO1, AO2) mA or 0-10 V DC can be selected.
Analog Input
17
17
18
18
19
19
20
20
21
21
17
17
18
18
19
19
20
20
21
21
17
18
19
20
V
21
Parameter
Description
Control Type
On/Off, PID, Heat/Cool, Floating and Feedback Control of Valves
Operating Voltage
20..60 V AC / 20..60 V DC or 85..265 V AC / 85..375 V DC
Relays / SSR
2 pieces SPST – NO 250 V AC 5A relays or 24 V DC 25 mA (SSR) drives
Dimensions (mm)
72 (Lenght) x 72 (Height) x 100 (Width)
Panel Cut-Out (mm)
68 (Lenght) x 68 (Height)
Analog Output
2 x 0..20 / 4..20 mA (Max. Load 600 Ohm) or 0..10 V DC optional
Analog Input
Universal (Note 1),
Communication (RS-485) Available (RS-485)
Digital Input
Available (optional)
Valve Feedback
None
Transmitter Supply
Available
Weight
232 g
Power Consumption Max. 7 W (10 VA)
Operating Temperature – 10 °C … 55 °C
Storage Temperature – 25 °C … 65 °C
Memory
Maks. 100.000 write
Protection Class
IP-65 Front Panel, IP-20 Rear Case
Notes:
(1) Universal Input :
Thermocouple
: B, E, J, K, L, N, R, S, T, U
Resistance Thermometer : Pt-100
Current
: 0-20 mA, 4-20 mA (Linear)
Voltage
: 0-50 mV, 0-1 V, 0.2- 1 V (Linear),
0-10 V DC, must be specified in the order.
Resolution
: 16 bit
Accuracy
: Thermocouple, Max. ±1.0 °C (Conversion and CJC error)
Resistance Thermometer, Max. ±0.5 °C
(Conversion and wire resistance compensation)
Linear Input, Max. % 0.1
ALARM SETTINGS
ACNF
CONTROL SET SETTINGS
SETP
INPUT SETTINGS
gcnf
7. PARAMETER TABLE
Description INP1 Analog Input 1 Type
DP Decimal Point SCLO Analog Input 1 Linear Scale Lower Value SCHI Analog Input 1 Linear Scale Upper Value UNIT Temperature Unit OFST Analog Input 1 Offset Value FLTR Analog Input 1 Filter SNBR Analog Input 1 Sensor Broken Behaviour ADRS Modbus Adress BAUD Modbus Baud Rate [4.8, 9.6, 19.2, 38.4 kbaud] PRTY Modbus Parity [None, ODD, Even]
SPSR Control Set Point Source SPLL Control Set Point Lower Limit SPHL Control Set Point Upper Limit SPRR Control Set Point Ramping Rate S-1 1. Step Set Value T-1 1. Step Time S-2 2. Step Set Value T-2 2. Step Time S-3 3. Step Set Value T-3 3. Step Time
A1TP Alarm 1 Type A1SP Alarm 1 Set Point A1HY Alarm 1 Hysteresis A1LT Alarm 1 Lock A2TP Alarm 2 Type A2SP Alarm 2 Set Point A2HY Alarm 2 Hysteresis A2LT Alarm 2 Lock
Min Maks Unit
Table 1
0
3
-199.9 999.9 EU
-199.9 999.9 EU
*C *F
-100.0 100.0 EU 1 15 s
LO HI
1 127
4.8 38.4
Table 2 -199.9 SPHL EU SPLL 999.9 EU
OFF 60.0 EU/min SPLL SPHL EU
OFF 999.9 min SPLL SPHL EU
OFF 999.9 min SPLL SPHL EU
OFF 999.9 min
Table 3 -199.9 999.9 EU
0.0 999.9 EU DSB ENB
Table 3 -199.9 999.9 EU
0.0 999.9 EU DSB ENB
8. ACCESSING PARAMETERS
STEP 1:
STEP 2:
Security Code Configuration
Entry Page Selection
(Default: 10) and Entry
STEP 3: Parameter Selection and Configuration
Process Screen
199.8 200.0
Selected Page
12 12
43 SCOD
3 PAGE
3 3 Parameters . . .
0
GCNF
4
4
4
Adjustment
12
Enter
3
Return
4
Menu Access
43
9. APPLICATION EXAMPLES
1) Input: Pt-100 Relay / Alarm1: 50 °C Low, Relay2 / Alarm2: 55 °C High AO1: 4-20 mA PID Control Output inp1 a1tp a1sp a2tp a2sp ctyp rl1D rl2D ao1D ao1r pt lo 50.0 hi 55.0 sco al-1 al-2 co-1 4-20
2) Input: TC Type J, Relay1: On-Off Control Output, Relay2 / Alarm2: 350 °C High inp1 a2tp a2sp ctyp rl1D rl2D
j hi 350.0 sco Do-1 al-2
3) Input: TC Type K, Profile Control (Ramp up to 400°C in 10 minutes and wait for 60 minutes), Relay1: PID Control Output, AO1: Retransmission Output (4-20 mA, 0-1200 °C)
inp1 spsr s-1 t-1 s-2 t-2 ctyp trll trhl rl1D rl2D ao1D ao1r k prfl 400 10.0 400 60.0 sco 0 1200 co-1 al-2 pvtr 4-20
OUTPUTS
OCNF
CTYP CFRM CPRD MNPR TRTM DBND OLL OHL OMR PONC TRLL TRHL RL1D RL2D AO1D AO1R AO2D AO2R
Control Type Control Form [DIR, REV] Control Period Manual Mode Selection Floating Control Valve Travel Time Dead Band Control Output Lower Limit Control Output Upper Limit Control Output Manual Reset PID Power On Behaviour Retransmission Scale Lower Value Retransmission Scale Upper Value
Relay 1 Function Relay 2 Function Analog Output 1 Function Analog Output 1 Type Analog Output 2 Function Analog Output 2 Type
AT PID PB-1 PB-2 ITH ITC DTH DTC HYS
PID Auto Tune PID Parameter Type
Proportional Band + Proportional Band Integral Time + Integral Time Derivative Time + Derivative Time Hysteresis
SCOD DPRL APRL FCST
Security Code Parameter Access Level Parameter Setting Level Factory Settings [OFF, LOAD, SAVE, DFLT]
Table 4
DIR REV
1 250 s
DSB ENB
10 2500 s
0.1 25.0 %
0.0 OHL %
OLL 100.0 %
OLL OHL %
0
4
-199.9 TRHL EU
TRLL 999.9 EU
Table 5
Table 5
Table 6
Table 7.1 ve Table 7.2
Table 6
Table 7.1 ve Table 7.2
OFF ON
STD ADV
0.1 999.9 EU 0.1 999.9 EU OFF 9999 s OFF 9999 s OFF 2500 s OFF 2500 s 0.0 999.9 EU
0 9999
0
9
0
9
Table 1. Input Type Options b Type B Thermocouple e Type E Thermocouple j Type J Thermocouple k Type K Thermocouple l Type L Thermocouple
n Type N Thermocouple
r Type R Thermocouple s Type S Thermocouple
t u pt 0-20
Type T Thermocouple Type U Thermocouple Pt-100 0-20 mA
4-20 4-20 mA 0-50 0-50 mV
0.0-1 0-1 V 0.2-1 0.2-1 V
0-10 0-10 V (*)
2-10 2-10 V (*)
(*) Custom specified volt input
Table 2. Control Set Options int Internal adjustment with
keys prfl With Profile Control
Table 3. Alarm Options off Off lo Low Alarm hi High Alarm loD Low Deviation hiD High Deviation lob Band Alarm (In) hib Band Alarm (Out)
Table 4. Control Type Options off No Control sco Single (Heat) Dco Double (Heat/Cool) bnD Floating Control of Valve
Tablo 5. Relay Output Options co-1 PID + (Heating) co-2 PID – (Cooling) Do-1 On-Off + (Heating) Do-2 On-Off – (Cooling) al-1 Alarm 1 al-2 Alarm 2 al-3 Alarm 3 al-4 Alarm 4
Table 6. Analog Output Options co-1 PID + (Heating) co-2 PID – (Cooling) pvtr Process Value sptr Control Set Value
Table 7.1. Analog Output Range 0-20 0-20 mA 20-0 20-0 mA 4-20 4-20 mA 20-4 20-4 mA
Table 7.2. Analog Output Range 0-10 0-10 V 10-0 10-0 V 2-10 2-10 V 10-2 10-2 V
PID SETTINGS
tUNE
SECURITY
PRTC
For detailed information, you can access the comprehensive user manual of the device under the heading “User Manuals” at www.elimko.com.tr. You can also use the QR Code on the front for this.
Elimko Elektronik malat ve Kontrol Ticaret Ltd. ti. Ankara Sanayi Odasi 2. Organize Sanayi Bölgesi Alci OSB Mahallesi 2001. Cad. No:14 Temelli 06909 Ankara / TURKYE
Tel: +90 312 212 64 50 (Pbx) · Fax: +90 312 212 41 43 · E-mail: elimko@elimko.com.tr · www.elimko.com.tr
Documents / Resources
![]() |
Elimko E72P Universal Process Controllers [pdf] User Guide E72P Universal Process Controllers, E72P, Universal Process Controllers, Process Controllers |