Edge-corE-LOGO

Edge-corE AS9716-32D 400G Data Center Spine Switch

Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-PRODUCT - Copy

Package ContentsEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-1

  1. 32-Port 400G Data Center Spine Switch AS97 l 6-32D
  2. Rack mounting kit-2 front-post brackets, 2 rear-post brackets, 20 screws, and 2 ear-locking screws
  3. Power cord (included with AC PSUs only)
  4. Console cable-RJ-45 to DE-9
  5. Documentation-Quick Start Guide (this document) and Safety and Regulatory Information

OverviewEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-2

  1. Timing ports: 1 0 MHz, 1 PPS, ToD
  2. 32 x 400G QSFP-DD ports
  3. Management ports: 1 x 1 000BASE-T RJ-45, 2 x 1 0G SFP+, RJ-45 console, USB
  4. Product label
  5. 2 x AC PSUs
  6. 6 x fan trays
  7. 2 x grounding screws

System LEDs/Buttons

  • PS1/PS2: Green (OK), Amber (fault)
  • Diag: Green (OK), Amber (no OS or fault)
  • Fan: Green (OK), Amber (fault)
  • Loc: Flashing Amber (switch locator)
  • Reset Button

Port LEDs

QSFP-DD LEDs
400G: 1 LED Blue
200G Breakout: 1 LED White, 1-2 LEDs Green
1 00G Breakout: 1-4 LEDs Green S0G Breakout: 1 LED Cyan

Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-3

SFP+ 1 OG Mgmt LEDs

  • Green (l0G)
  • Amber (1 G)

RJ-45 Mgmt LED

  • Green (link/activity)

FRU Replacement

PSU ReplacementEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-4

  1. Remove the power cord.
  2. Press the release latch and remove the PSU.
  3. Install replacement PSU with matching airflow direction.

Fan Tray ReplacementEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-5

  1. Pull the handle release latch.
  2. Remove fan tray from the chassis.
  3. Install replacement fan with matching airflow direction.

Airflow Reversal

  1. F2B AirflowEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-6
    • Remove front-to-back (F2B) airflow fan trays (red handles) and PSUs (red release latches).
  2. B2F AirflowEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-7
    • Install back-to-front (B2F) airflow fan trays (blue handles) and PSUs (blue release latches).

Installation

Warning: For a safe and reliable installation, use only the accessories and screws provided with the AS9716- 32D. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.

Caution: The switch includes plug-in power supply (PSU) and fan tray modules that are installed into its chassis. Make sure all installed modules have a matching airflow direction (front-to­back or back-to-front).

Note: The switch has the Open Network Install Environment (ONIE) software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at www.edge-core.com.

  • The switch drawings in this document are for illustration only and may not match your particular switch model.

Mount the Switch

Caution: This device must be installed in a telecommunications room or a server room.
Attention: Cet appareil doit etre installe dons une salle de telecommunication ou une salle de serveur.

Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-9

  1. Attach the Brackets
    Use the included screws to attach the front- and rear-post brackets
  2. Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-10Mount the Switch
    Mount the switch in the rack and secure it with rack screws.Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-10
  3. Lock the Rear-Post Brackets
    Use the included screws to lock the position of the rear-post brackets.Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-8

Connect PowerEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-11

AC Power: Install one or two AC PSUs and connect them to an AC power source.

Caution: Use a UL/IEC/EN 60950-1 certified power supply to connect to a DC converter.
Attention: Utilisez une alimentation certifiee UL/IEC/EN 60950-1 pour le conneder a un convertisseur CC. Caution: All DC power connections should be performed by a qualified professional.
Attention: Toutes les connexions d’alimentation CC doivent etre effectuees par un professionnel qualifie.

Make Network Connections

Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-12

QSFP-DD Ports
Install transceivers and then connect fiber optic cabling to the transceiver ports.
Alternatively, connect DAC or AOC cables directly to the QSFP-DD slots.

 Connect Timing Ports

Edge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-13

1 PPS and 10 MHz Ports

  • Use coax cables to connect the 1-pulse-per-second (1 PPS) and
  • 10 MHz IN/OUT ports to other synchronized devices.

ToD Port

  • Use a shielded cable to connect the Time-of-Day (ToD) port to other devices that use ToD synchronization signals.

Make Management ConnectionsEdge-corE-AS9716-32D-400G-Data-Center-Spine-Switch-FIG-14

10/100/1 000M RJ-45 Management Port

  • Connect Cat. Se or better twisted-pair cable.

1 0G SFP+ Management Ports

  • Install transceivers and then connect fiber optic cabling to the transceiver ports.

RJ-45 Console Port

  • Connect the included console cable and then configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.

Hardware Specifications

Switch Chassis

  • Size (WxDxH): 438.4 x 536 x 43.1 mm (17 .26 x 21.1 x 1.7 in.)
  • Weight: 11 .06 kg (24.38 lb), with 2 PSUs and 6 fans installed
  • Temperature: Operating: 0° C to 45° C (32° F to 113° F)
  • Storage: -40° C to 70° C (-40° F to 158° F)
  • Humidity Operating: 5% to 95% (non-condensing)
  • Power: 1 300 Watts maximum
    Consumption

AC PSU
Input Power: 100-120 VAC, 50-60 Hz, 12 A max. 200-240 VAC, 50-60 Hz, 7.5 A max. 190-310 VDC, 8-5 A

  • Rating

Regulatory Compliances

  • Emissions

Immunity:

  • EN 55032:201 S+AC:2016, Class A
  • EN 61000-3-2:2014, Class A
  • EN 61000-3-3:2013
  • FCC Class A
  • VCCI Class A
  • CCC GB 9254-2008, Class A
  • EN 55035:2017
  • EN 55024:201 0+A 1:2015
  • IEC 61000-4-2/3/4/5/6/8/1 l

Safety: UL (CSA 22.2 No 62368-1 & UL62368- l) CB (IEC/EN60950- l & IEC/EN 62368-1) CCC GB4943. l -201 l