dynamic BIOSENSORS AS-2-Rb-lfs Adapter Strand 2 User Manual

ADAPTER STRAND 2
with red dye Rb and prehybridized with ligand strand Dynamic Biosensors GmbH & Inc.
AS-2-Rb-lfs v5.1

Key Features

  • Adapter strand 2 for functionalization of heliX® Adapter Chip Spot 2.
  • Compatible with heliX ® Adapter Chip.
  • Includes Adapter strands for 50 regenerations.
  • Ideal for MIX&RUN sample preparation.
  • Adapter strand 2 carries a hydrophilic red dye (Rb) with a neutral net charge.

heliX ® Adapter Chip Overview

2 spots with 2 different anchor sequences for DNA-encoded addressing.
Adapter Chip Overview
Spot 1
Adapter Chip Overview
Spot 2

Product Description

Order Number : AS-2-Rb-lfs

Table 1. Contents and Storage Information

Material Cap Concentration Amount Buffer Storage
Adapter strand 2 Rb lfs White 200/250 nM 5 x 200 µL TE40 [1] -20°C

For research use only.
This product has a limited shelf life, please see expiry date on label.
To avoid many freeze thaw cycles please aliquot the nanolever.

Preparation | MIX&RUN

In-solution hybridization of adapter and ligand strands:

  1. Mix Adapter strand 1 – Rb (400 nM) and conjugated Ligand strand (500 nM) at 1:1 ratio (v/v).
  2. Incubate the solution of step 1 at RT at 600 rpm for 30 min to ensure complete hybridization.
  3. Mix solution of step 2 and Adapter strand 2 – Rb – lfs (200 nM) at 1:1 ratio (v/v).

Preparation MIX&RUN
Solution is ready to use for bio chip fictionalization.
Stability of the solution is related to the stability of the ligand molecule.

Table 2. Additional material for fictionalization of spot 1 and reference spot 2.

Material Concentration Buffer Related Product Name Order No
Adapter strand 1 Rb 400 nM TE40 [1] Adapter strand 1 with red dye Rb AS-1-Rb
Ligand strand carrying the conjugated ligand 500 nM 2P] E40 [ heliX® Amine Coupling Kit 1 HK-NHS-1

Example

Required volume for 3 functionalizations: 100 µL with a final concentration of 100 nM.

Vial 1 Vial 2
Adapter strand 1 Rb(400 nM) Conjugated Ligand strand(500 nM) Adapter strand 1 Rb lfs(200/250 nM)
25 µL 25 µL 50 µL

After incubation time, mix vial 1 and vial 2 to obtain 100 µL of ready-to-use DNA solution.

Contact

Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany

Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
Woburn, MA 01801
USA

Order Information order@dynamic-biosensors.com
Technical Support support@dynamic-biosensors.com

www.dynamic-biosensors.com
Instruments and chips are engineered and manufactured in Germany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. All rights reserved.

  1. TE 40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
  2. If the protein is not stable in PE40 (TE40, HE40), please check buffer compatibility with the switchSENSE® compatibility sheet.

AS-2-Rb-lfs v5.1 www.dynamic-biosensors.com

Documents / Resources

dynamic BIOSENSORS AS-2-Rb-lfs Adapter Strand 2 [pdf] User Manual
AS-2-Rb-lfs v5.1, AS-2-Rb-lfs Adapter Strand 2, AS-2-Rb-lfs, Adapter Strand 2, Strand 2

References

Leave a comment

Your email address will not be published. Required fields are marked *