Danfoss PVG 100 Electrical Actuating Module

Danfoss-PVG-100-Electrical-Actuating-Module-PRODUCT

Installation Guide

Electrical Actuating Module

PVE series 4 for PVG 32 and PVG 100

Oil flow direction for standard assembled group@Danfoss-PVG-100-Electrical-Actuating-Module- (2)

For Technical Information, see Danfoss.com

Mounting PVE

Instruction coversDanfoss-PVG-100-Electrical-Actuating-Module- (3)

  • Protect LVDT-pin if present
  • Ensure O-rings are in place
  • Ensure gasket when using AMP and DIN/Hirschmann connector
  • Do not over torque

warning
PVEA is not for use on PVG 100

All PVE variants. PVEO and PVEO-R are without LVDTDanfoss-PVG-100-Electrical-Actuating-Module- (4)

Version ON/OFF

  • Ground pins are internally connected.
  • Pin 3 is not connected on
    Hirschmann/DIN version of PVEO.
  • UDC2 supplies electronics for feedback signal on PVEO-DI.

Connection PVEO with direction indication (DI)

Connector 1 A UDC B UDC Gnd Gnd
AMP (grey) p 1 p 2 p 3 p 4
Connector 2 DI-B DI-A Gnd UDC 2
AMP (black) p 1 p 2 p 3 p 4

Danfoss PVG 100 Electrical Actuating Module Installation Guide Featured Image: No file chosen Update Post Add MediaVisualText Paragraph p Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 15 of 15 media items Attachment Details Danfoss-PVG-100-Electrical-Actuating-Module-5.png September 13, 2024 36 KB 393 by 492 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title Danfoss-PVDanfoss-PVG-100-Electrical-Actuating-Module- (5)G-100-Electrical-Actuating-Module- (5) Caption Description File URL: https://manuals.plus/wp-content/uploads/2024/09/Danfoss-PVG-100-Electrical-Actuating-Module-5.png Copy URL to clipboard Attachment Display Settings Alignment Center Link To None Size Full Size – 393 × 492 Selected media actions 1 item selected Clear Insert into post No file chosen

Connection PVEO standard

Connector A B
AMP/Hirschmann/DIN pin 1 pin 2
Deutsch pin 1 pin 4
Function A (pin 1) B (pin 2)
Neutral 0 0
Q: P ® A UDC 0
Q: P ® B 0 UDC

Control all PVEO

Connector A B
AMP

Hirschmann/DIN

pin 1 pin 2
Deutsch pin 1 pin 4

DI general not

  • On DI versions two UDC connections (UDC and UDC2) are necessary.
    UDC will supply the electronics and
  • UDC2 will supply the solenoid valves  two ground pins are internally connected.
    With advantages two separate power supplies can be used, see also Technical information for PVE series 4.

Danfoss-PVG-100-Electrical-Actuating-Module- (6)

Proportional Version

Standard PVE
Connection PVEA/PVEH/PVEM/PVES/PVEU – also with  oat B four pin

Connector US UDC Gnd Error
AMP pin 1 pin 2 pin 3 pin 4
Hirschmann/ DIN pin 2 pin 1 gnd pin 3
Deutsch pin 1 pin 4 pin 3 pin 2
  • On PVEM the error pin is not used and not connected (pin 3 Hirschmann/DIN).
  • Ground pins are internally connected.Danfoss-PVG-100-Electrical-Actuating-Module- (7)

Control (US) for standard mounted PVEA/ PVEH/ PVEM/ PVES

Function Voltage relative PWM
Neutral 0,5 • UDC 50%
Q: P ® A 0,5 ® 0,25 • UDC 50% ® 25%
Q: P ® B 0,5 ® 0,75 • UDC 50% ® 75%
Function Voltage relative PWM
Neutral 0,5 • UDC 50%
Q: P ® A 0,5 ® 0,34 • UDC 50% ® 34%
Q: P ® B 0,5 ® 0,65 • UDC 50% ® 65%
Float 0,75 • UDC 75%

Danfoss-PVG-100-Electrical-Actuating-Module- (8)

Standard PVE with DI
Connection PVE with direction indication (DI)

Connector 1 US UDC 1 Gnd Error
AMP (grey) p 1 p 2 p 3 p 4
Deutsch p 1 p 4 p 3 p 2
Connector 2 DI-B DI-A Gnd UDC 2
AMP (black) p 1 p 2 p 3 p 4
Deutsch p 4 p 3 p 2 p 1

 

Danfoss-PVG-100-Electrical-Actuating-Module- (9)Control (US) for standard mounted PVEA–DI/ PVEH–DI

Function US PWM
Neutral 0,5 • UDC 50%
Q: P ® A 0,5 ® 0,25 • UDC 50% ® 25%
Q: P ® B 0,5 ® 0,75 • UDC 50% ® 75%
  • Ground pins are internally connected.
  • UDC2 only supplies electronics for feedback signal and error pin on PVEA-DI / PVEH-DI. Two separate power sources can be used.

Standard PVE with SP
Connection PVE with Spool Position (SP)

Connector US Error SP Gnd UDC
Deutsch p 1 p 2 p 4 p 5 p 6

Danfoss-PVG-100-Electrical-Actuating-Module- (10)

Control (US) for standard mounted PVES-SP

Function US PWM
Neutral 0,5 • UDC 50%
Q: P ® A 0,5 ® 0,25 • UDC 50% ® 25%
Q: P ® B 0,5 ® 0,75 • UDC 50% ® 75%

PVE with separate
Float pin Connection PVEH with float A six pin

Connector US (control) UDC (power) Float Ground Error
AMP pin 1 pin 2 pin 5 pin 3 pin 4
Deutsch pin 1 pin 6 pin 3 pin 5 pin 2

PWM controlled PVE – PVEP Connection PVEP

Connector PWM A Error PWM B Gnd UDC
Deutsch p 1 p 2 p 3 p 5 p 6
Function PWM A PWM B
Neutral < 10% < 10%
Q: P ® A 10% ® 80% < 10%
Q: P ® B < 10% 10% ® 80%

Danfoss-PVG-100-Electrical-Actuating-Module- (11)

Safety and Monitoring

Fault monitoring overview

 

Type

 

Fault monitoring

 

Delay before error out

 

Error mode

Error output status Fault output on PVE 1)  

LED light

Memory (reset needed)
PVEO PVEM No fault monitoring
 

 

PVEA PVEH PVEP PVES PVEU

 

Active

 

500 ms

(PVEA: 750 ms)

No fault Low < 2 V Green
Input signal faults  

High

 

 

~UDC

Flashing red  

Yes

Transducer (LVDT) Constant red
Close loop fault
 

Passive

 

250 ms

(PVEA: 750 ms)

No fault Low < 2 V Green
Input signal faults  

High

 

 

~UDC

Flashing red  

No

Transducer (LVDT) Constant red
Close loop fault
PVE

Float six pin

 

Active

500 ms Float not active  

High

 

 

~UDC

 

Constant red

 

Yes

750 ms Float still active
  1. Measured between fault output pin and ground.

Spool Position Feedback (-SP

The –SP functionality is a 0,5V to 4,5V inverted feedback with 2,5V as neutral value.

Danfoss-PVG-100-Electrical-Actuating-Module- (12)Direction Indication Feedback (-DI)

Danfoss-PVG-100-Electrical-Actuating-Module- (13)

As shown in the figure, both “DI-A” and “DI-B” signals are “High” when the spool is in neutral position. When the spool is moving in the A direction, the “DI-A” signal goes “Low” and the “DI-B” signal stays “High”. The reverse is true when the spool is moved in the B direction.
Direction Indication Feedback (-DI)

Both direction indication signals go low when the error indicator goes high.

Values for both Direction Indicators, pin A and pin B

Transition to low from high 0.8 ± 0.1 mm [0.031 in]
Transition to high from low 0.4 ± 0.1 mm [0.015 in]
Transition to low both pins error pin goes high
Maximum load of “DI-A” , “DI-B” 50 mA
Voltage UDC high by load 20 mA > UDC –1.5 V
Voltage UDC high by load 50 mA > UDC –2.0 V
Voltage low < 0.2 V

Technical data

The following technical data are from typical test results. For the hydraulic system a mineral based hydraulic oil with a viscosity of 21 mm2/s [102 SUS] and a temperature of 50°C [122°F] were used.

Supply voltage UDC rated 12 V DC 24 V DC
range 11 V to 15 V 22 V to 30 V
max. ripple 5%
Current consumption at rated voltage 0.65 A @ 12 V 0.33 A @ 24 V
Signal voltage (PVEM) neutral 0.5 x UDC
A-port « B-port 0.25 • UDC to 0.75 • UDC
Signal current at rated voltage (PVEM) 0.25 mA 0.50 mA
Input impedance in relation to 0.5 • UDC 12 KW
Power consumption 8 W

PVEA, PVEH, PVEP, PVES, PVEU

Supply voltage UDC rated / range 11 V to 32 V
max. ripple 5%
Current consumption

at rated voltage              PVEH/PVEP/PVES/PVEU (PVEA)

0.57 (0.28) A @ 12 V 0.3 (0.15) A @ 24 V
 

 

 

Signal voltage

PVEA/PVEH/PVES – neutral 0.5 x UDC
PVEA/PVEH/PVES – A-port « B-port 0.25 • UDC to 0.75 • UDC
PVEU – neutral 5V
PVEU – A-port « B-port 2.5V to 7.5V
PVEP – neutral A< 10%, B < 10%
PVEP – A-port 10%<A<80%, B< 10%
PVEP – B-port A< 10%, 10%<B<80%
Signal currentat rated voltage 0.25 mA to 0.70 mA
Input impedance in relation to 0.5 • UDC 12 KW
Input capacitor 100 hF
Power consumption        PVEH/PVEP/PVES/PVEU (PVEA) 7 (3.5) W

Oil viscosity

 

 

Oil viscosity

range 12 – 75 mm2/s [65 – 347 SUS]
min. 4 mm2/s [39 SUS]
max. 460 mm2/s [2128 SUS]

Note: Max. start up viscosity 2500 mm2/s

NB: In particularly exposed applications, protection by screen is recommended.

Bleeding
If the group is installed vertically, it is recommended to bleed it at the adjusting screws (Pos.A)
Note: Because of the hydraulic build-up of PVEA, it may be necessary to bleed the PVEK.

Danfoss-PVG-100-Electrical-Actuating-Module- (1)

Protection
All PVE modules comply with protection class IP65 in accordance with IEC 529. However, in particularly exposed applications protection in the form of screening is recommended.

Warning

All marks and brands of valves – inclusive proportional valves – can fail and cause serious damage. It is therefore important to analyse all aspects of the application.
Because the proportional valves are used in many different operation conditions and applications, the manufacturer of the application is alone responsible for making the final selection of the products – and assuring that all performance, safety and warning requirements of the application are met.
The process of choosing the control system – and safety level – could e.g. be governed by EN 954-1 (Safety related parts of control system). See also Technical information for PVE series 4.

Accessories

Connector code numbers

Part number Name
157B4992 AMP CONNECTING KIT (GREY) 4 pin with housing, contact and wire sealing
157B4993 AMP CONNECTING KIT (BLACK) 4 pin with housing, contact and wire sealing
984L3165 EL-PLUG, ON-OFF black Hirschmann DIN connector set*

Set of seals code numbers

Part number Name Actuator
157B4997 Set of seals PVE for PVG 32/ PVG 100
155G8519 Set of seals PVE for PVG 120
11061235 Set of seals PVHC for PVG 32/ PVG 100

Cables code numbers

Feature Wire colors Length Code number
Connector pin 1 pin 2 pin 3 pin 4 pin 5 pin 6
Deutsch 4 pin white blue yellow red 4 m 11007498
6 pin white blue yellow red black green 4 m 11007513
AMP 4 pin white blue yellow red 4 m 157B4994
6 pin white red black yellow green blue 5 m 157B4974
AMP/black coding 4 pin white blue yellow red 4 m 157B4995

520L0619 • Rev EB • Mar 2014

Documents / Resources