Shenzhen-LOGO

Shenzhen Technology K5EM Standalone Keypad Access Control

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-PRODUCT

Cyfarwyddiadau Defnydd Cynnyrch

  • Before using the reader for the first time, make sure to fully charge it using the provided charger. Connect the charger to the device and a power source.
  • To turn on the reader, press and hold the power button until the screen lights up. To turn it off, press and hold the power button again and follow the on-screen prompts.
  • Use the touch screen to navigate through your documents. Swipe left or right to turn pages, and pinch to zoom in or out for better readability.
  • Gallwch drosglwyddo files to the reader using a USB cable connected to your computer. Simply drag and drop your files into the designated folder on the device.
  • Explore the settings menu to customize your reading experience. You can adjust brightness, font size, and other display settings to suit your preferences.

Rhestr Pacio

Enw Nifer Sylwadau
Bysellbad 1  
Defnyddiwr llaw    
Gyrrwr sgriw 1 < P20 mm x 60 mm, Special for keypad
Plwg rwber 2 < P6 mm x 30 mm, used for fixing
Sgriwiau hunan-dapio 2 ¢ 4 mm x 28 mm, defnyddio ar gyfer trwsio
Seren sgriwiau   < P3 mm x 6 mm, used for fixing

Please ensure that all the above contents are correct. If any are missing, please notify the supplier of the unit.

Canllaw Rhaglennu Cyfeirio Cyflym

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-1

Disgrifiad

The unit is a single-door multifunction standalone access controller or a Wiegand output keypad, or a card reader. It is suitable for mounting either indoors or outdoors in harsh environments. It is housed in a strong, sturdy, and vandal-proof Zinc Alloy electroplated case, which is available in either a bright silver or matt silver finish. The electronics are fully potted, so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4-digit PIN, or a Card + PIN option. The built-in card reader supports 125 KHz EM cards. The unit has many extra features, including lock output current short circuit protection, Wiegand output, and a backlit keypad. These features make the unit an ideal choice for door access, not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks, and prisons.

Nodweddion

  • Dal dŵr, yn cydymffurfio â IP65 / IP68
  • Achos gwrth-fandal Electroplatiedig Alloy Sinc Cryf
  • Rhaglennu llawn o'r bysellbad
  • 2000 o ddefnyddwyr, yn cefnogi Cerdyn, PIN, Cerdyn + PIN
  • Gellir ei ddefnyddio fel bysellbad annibynnol
  • Allweddi backlight
  • Master add card/delete card support
  • Mewnbwn Wiegand 26 i'w gysylltu â darllenydd allanol
  • Allbwn Wiegand 26 i'w gysylltu â rheolydd
  • Amser Allbwn Drws Addasadwy, Amser larwm, Drws Amser agored
  • Defnydd pŵer isel iawn (30mA)
  • Cyflymder gweithredu cyflym, <20ms gyda 2000 o ddefnyddwyr
  • Allbwn cloi amddiffyniad cylched byr cyfredol
  • Hawdd i'w osod a'i raglennu
  • Buzzer adeiledig
  • Red, Yellow, and Green LEDS display the working status

Manylebau

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-10

Gosodiad

  • Tynnwch y clawr cefn o'r bysellbad gan ddefnyddio'r gyrrwr sgriw arbennig a gyflenwir
  • Drill 2 holes on the wall for the self tapping screws and dig a hole for the cable
  • Rhowch y byngiau rwber a gyflenwir yn y ddau dwll
  • Gosodwch y clawr cefn yn gadarn ar y wal gyda 2 sgriw tapio hunan
  • Rhowch y cebl trwy dwll y cebl
  • Atodwch y bysellbad i'r clawr cefn.

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-2

Gwifrau

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-11

Diagram cyflenwad pŵer cyffredin:

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-3

Diagram cyflenwad pŵer arbennig:

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-4

To Reset to Factory Default and Match the Master Card

Ailosod i Ffatri ddiofyn

Method 1: Power off, power on, when the indicator light turns orange, press the # key, swipe the first card as for master add card, swipe the second card as for maste,r delete card, on hearing tick Tick-tick sound thrice, the master code has been reset to 999999, factory default settings are successful.

Dull 2: Power off, press the exit button continuously, power on, sound “tick-tick” twice, then Release the hand, the indicator light turns orange, if you need to register master cards, pls swipe the first card as for master add card, swipe the second card as for master, delete card within 10s, if not, sound “tick-” once after 10s, the master code has been reset to 999999, factory default settings is successful.
* Registered user data won’t be deleted when reset to factory default.

Gweithrediad Cardiau Meistr

Ychwanegu Cerdyn

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-12

Nodyn: The master add card is used to add card users continuously and quickly. When you read the master add card for the first time, you will hear a short “BEEP” sound once, and the indicator light turns orange, which means you have entered the add user programming. When you read the master adda card for the second time, you will hear a long “BEEP” sound once, and the indicator light turns on Red, which means you have exited the add user programming.

Dileu Cerdyn

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-13

Nodyn: The master delete card is used to delete card users continuously and quickly. When you read the master delete card for the first time, you will hear a short “BEEP” sound once, and then the indicator light turns orange, it means you have entered delete user programming. When you read the master delete card for the second time, you will hear a long “BEEP” sound once, then the indicator light turns red, it means you have exited the delete user programming.

Arwydd Sain a Golau

Statws Gweithredu Golau Coch Golau Gwyrdd Melyn Ysgafn Swniwr
Pŵer ymlaen   Disglair   Di
Arhoswch Disglair      
Pwyswch bysellbad       Di
Gweithrediad yn llwyddiannus   Disglair   Di
Methodd y gweithrediad       DiDiDi
Rhowch y modd rhaglennu i mewn Disglair      
Yn y modd rhaglennu     Disglair Di
Gadael o'r modd rhaglennu Disglair     Di
Agorwch y drws   Disglair   Di
Larwm Disglair     Larwm

Canllaw Rhaglennu Manwl

Gosodiadau Defnyddiwr

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-5Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-6Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-7Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-14

Gosodiadau Drws

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-15Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-8

The unit is operating as a Wiegand Output Reader
The unit supports a Wiegand 26-bit output, so the Wiegand data wires can be connected to any controller that supports a Wiegand 26-bit input.Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-9

DATGANIAD Cyngor Sir y Fflint

RHYBUDD FCC
This device complies with part 15 of the FCC Rules. Operation is subject to toThe following two conditions:

  1. Efallai na fydd y ddyfais hon yn achosi ymyrraeth niweidiol, a
  2. rhaid i'r ddyfais hon dderbyn unrhyw ymyrraeth a dderbynnir, gan gynnwys ymyrraeth a allai achosi gweithrediad annymunol.

Any changes or modifications not expressly approved by the party Responsible for compliance could void the user’s authority to operate the equipment.

NODYN: Mae'r offer hwn wedi'i brofi a chanfuwyd ei fod yn cydymffurfio â'r terfynau ar gyfer dyfais ddigidol Dosbarth B, o dan Ran 15 o Reolau Cyngor Sir y Fflint. Mae'r terfynau hyn wedi'u cynllunio i ddarparu amddiffyniad rhesymol rhag ymyrraeth niweidiol mewn gosodiad preswyl. Mae'r offer hwn yn cynhyrchu, yn defnyddio ac yn gallu pelydru ynni amledd radio ac, os na chaiff ei osod a'i ddefnyddio yn unol â'r cyfarwyddiadau, gall achosi ymyrraeth niweidiol i gyfathrebiadau radio. Fodd bynnag, nid oes unrhyw sicrwydd na fydd ymyrraeth yn digwydd mewn gosodiad penodol. Os yw'r offer hwn yn achosi ymyrraeth niweidiol i dderbyniad radio neu deledu, y gellir ei bennu trwy droi'r offer i ffwrdd ac ymlaen, anogir y defnyddiwr i geisio cywiro'r ymyrraeth gan un neu fwy o'r mesurau canlynol:

  • Ailgyfeirio neu adleoli'r antena sy'n derbyn.
  • Cynyddu'r gwahaniad rhwng yr offer a'r derbynnydd.
  • Cysylltwch yr offer ag allfa ar gylched sy'n wahanol i'r un y mae'r derbynnydd wedi'i gysylltu ag ef.
  •  Cysylltwch â'r deliwr neu dechnegydd radio/teledu profiadol am gymorth.

Er mwyn parhau i gydymffurfio â chanllawiau Datguddio RF Cyngor Sir y Fflint, Dylid gosod a gweithredu'r offer hwn gyda phellter o 20cm o leiaf rhwng y rheiddiadur a'ch corff: Defnyddiwch yr antena a gyflenwir yn unig.

FAQ

  • Q: Sut ydw i'n ailosod y ddyfais?
  • A: To reset the reader, locate the reset button (usually a small hole) and use a paperclip to press and hold it for a few seconds.
  • Q: Can I expand the storage capacity?
  • A: Yes, you can insert a microSD card into the designated slot to expand the storage capacity of the device.

Dogfennau / Adnoddau

Shenzhen Technology K5EM Standalone Keypad Access Control [pdfLlawlyfr Defnyddiwr
2BK4E-K5EM, 2BK4EK5EM, K5EM Standalone Keypad Access Control, K5EM, Standalone Keypad Access Control, Keypad Access Control, Access Control, Control

Cyfeiriadau

Gadael sylw

Ni fydd eich cyfeiriad e-bost yn cael ei gyhoeddi. Mae meysydd gofynnol wedi'u marcio *