Shenzhen-LOGO

Shenzhen Technology K5EM Standalone Keypad Access Control

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-PRODUCT

Product Usage Instructions

  • Before using the reader for the first time, make sure to fully charge it using the provided charger. Connect the charger to the device and a power source.
  • To turn on the reader, press and hold the power button until the screen lights up. To turn it off, press and hold the power button again and follow the on-screen prompts.
  • Use the touch screen to navigate through your documents. Swipe left or right to turn pages, and pinch to zoom in or out for better readability.
  • You can transfer files to the reader using a USB cable connected to your computer. Simply drag and drop your files into the designated folder on the device.
  • Explore the settings menu to customize your reading experience. You can adjust brightness, font size, and other display settings to suit your preferences.

Packing List

Name Quantity Remarks
Keypad 1  
User manual    
Screw driver 1 < P20 mm x 60 mm, Special for keypad
Rubber plug 2 < P6 mm x 30 mm, used for fixing
Self tapping screws 2 ¢ 4 mm x 28 mm, used for fixing
Star screws   < P3 mm x 6 mm, used for fixing

Please ensure that all the above contents are correct. If any are missing, please notify the supplier of the unit.

Quick Reference Programming Guide

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-1

Description

The unit is a single-door multifunction standalone access controller or a Wiegand output keypad, or a card reader. It is suitable for mounting either indoors or outdoors in harsh environments. It is housed in a strong, sturdy, and vandal-proof Zinc Alloy electroplated case, which is available in either a bright silver or matt silver finish. The electronics are fully potted, so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4-digit PIN, or a Card + PIN option. The built-in card reader supports 125 KHz EM cards. The unit has many extra features, including lock output current short circuit protection, Wiegand output, and a backlit keypad. These features make the unit an ideal choice for door access, not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks, and prisons.

Features

  • Waterproof, conforms to IP65/IP68
  • Strong Zinc Alloy Electroplated anti-vandal case
  • Full programming from the keypad
  • 2000 users, supports Card, PIN, Card + PIN
  • Can be used as a standalone keypad
  • Backlight keys
  • Master add card/delete card support
  • Wiegand 26 input for connection to external reader
  • Wiegand 26 output for connection to a controller
  • Adjustable Door Output time, Alarm time, Door Open time
  • Very low power consumption (30mA)
  • Fast operating speed, <20ms with 2000 users
  • Lock output current short circuit protection
  • Easy to install and programme
  • Built-in buzzer
  • Red, Yellow, and Green LEDS display the working status

Specifications

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-10

Installation

  • Remove the back cover from the keypad using the supplied special screw driver
  • Drill 2 holes on the wall for the self tapping screws and dig a hole for the cable
  • Put the supplied rubber bungs into the two holes
  • Fix the back cover firmly on the wall with 2 self tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover.

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-2

Wiring

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-11

Common power supply diagram:

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-3

Special power supply diagram:

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-4

To Reset to Factory Default and Match the Master Card

Reset to Factory Default

Method 1: Power off, power on, when the indicator light turns orange, press the # key, swipe the first card as for master add card, swipe the second card as for maste,r delete card, on hearing tick Tick-tick sound thrice, the master code has been reset to 999999, factory default settings are successful.

Method 2: Power off, press the exit button continuously, power on, sound “tick-tick” twice, then Release the hand, the indicator light turns orange, if you need to register master cards, pls swipe the first card as for master add card, swipe the second card as for master, delete card within 10s, if not, sound “tick-” once after 10s, the master code has been reset to 999999, factory default settings is successful.
* Registered user data won’t be deleted when reset to factory default.

Master Card Operation

Add Card

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-12

Note: The master add card is used to add card users continuously and quickly. When you read the master add card for the first time, you will hear a short “BEEP” sound once, and the indicator light turns orange, which means you have entered the add user programming. When you read the master adda card for the second time, you will hear a long “BEEP” sound once, and the indicator light turns on Red, which means you have exited the add user programming.

Delete Card

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-13

Note: The master delete card is used to delete card users continuously and quickly. When you read the master delete card for the first time, you will hear a short “BEEP” sound once, and then the indicator light turns orange, it means you have entered delete user programming. When you read the master delete card for the second time, you will hear a long “BEEP” sound once, then the indicator light turns red, it means you have exited the delete user programming.

Sound and Light indication

Operation Status Red Light Green Light Yellow Light Buzzer
Power on   Bright   Di
Stand by Bright      
Press keypad       Di
Operation successful   Bright   Di
Operation failed       DiDiDi
Enter programming mode Bright      
In the programming mode     Bright Di
Exit from the programming mode Bright     Di
Open the door   Bright   Di
Alarm Bright     Alarm

Detailed Programming Guide

User Settings

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-5Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-6Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-7Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-14

Door Settings

Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-15Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-8

The unit is operating as a Wiegand Output Reader
The unit supports a Wiegand 26-bit output, so the Wiegand data wires can be connected to any controller that supports a Wiegand 26-bit input.Shenzhen-Technology-K5EM-Standalone-Keypad-Access-Control-FIG-9

FCC STATEMENT

FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to toThe following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party Responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  •  Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with a minimum 20cm distance between the radiator and your body: Use only the supplied antenna.

FAQ

  • Q: How do I reset the device?
  • A: To reset the reader, locate the reset button (usually a small hole) and use a paperclip to press and hold it for a few seconds.
  • Q: Can I expand the storage capacity?
  • A: Yes, you can insert a microSD card into the designated slot to expand the storage capacity of the device.

Documents / Resources

Shenzhen Technology K5EM Standalone Keypad Access Control [pdf] User Manual
2BK4E-K5EM, 2BK4EK5EM, K5EM Standalone Keypad Access Control, K5EM, Standalone Keypad Access Control, Keypad Access Control, Access Control, Control

References

Leave a comment

Your email address will not be published. Required fields are marked *