Rhyngwyneb KNX Intesis INKNXHIS001R000 gyda Mewnbynnau Deuaidd
Manylebau
- Rhif yr eitem: INKNXHIS001R000
- Cysylltwyr / Mewnbwn / Allbwn: KNX, HVAC port, Binary inputs (dry contact)
- Dangosyddion LED: KNX
- Gwlad Tarddiad: Sbaen
- Gwarant: 3 mlynedd
Gwybodaeth Cynnyrch
The Hisense-KNX interface allows full bidirectional communication between Hisense VRF systems units and KNX installations. It has four potential-free binary inputs to integrate external devices (such as window contacts or presence detectors), with the corresponding internal functions available to help improve energy efficiency.
Nodweddion a Manteision
- Cyfluniad ETS
Mae'r rhyngwyneb wedi'i ffurfweddu gan ddefnyddio meddalwedd offeryn ffurfweddu safonol ETS. - Multiple energy efficiency functions available
Timeout, open window, or occupancy energy-saving functions are available to reduce energy costs. - Total unit control and monitoring from KNX
Trwy newidynnau mewnol, cyfrif oriau rhedeg (at ddibenion cynnal a chadw), a dangosydd gwallau. - Rheolaeth uned AC gan y rheolydd o bell a KNX
Gellir rheoli'r uned AC ar yr un pryd gan reolwr o bell y gwneuthurwr a KNX. - Yn gydnaws â phob thermostat KNX yn y farchnad
Mae'r holl wrthrychau DPT sydd eu hangen i fod yn gydnaws â phob thermostat KNX yn y farchnad ar gael. - Smooth KNX thermostat integration
Caniateir i thermostatau KNX reoli'r uned AC trwy synhwyrydd tymheredd y thermostat. - Up to five scenes saved/executed from KNX
Up to five scenes can be saved and executed from KNX. - Compact dimensions, allowing inside installation
The interface can be quickly installed inside the AC unit thanks to its reduced dimensions.
Cyffredinol | |
Lled Net (mm) | 71 |
Uchder Net (mm) | 71 |
Dyfnder Net (mm) | 27 |
Pwysau Net (g) | 80 |
Lled wedi'i bacio (mm) | 12 |
Uchder wedi'i bacio (mm) | 6 |
Dyfnder Pacio (mm) | 8 |
Pwysau wedi'i bacio (g) | 120 |
Opera ng Temperature °C Min | -25 |
Opera ng Temperature °C Max | 60 |
Tymheredd Storio °C Isafswm | -40 |
Tymheredd Storio °C Uchafswm | 85 |
Power Consump on (W) | 0.232 |
Mewnbwn VoltagE (v) | 29 VDC |
Pŵer Connector | 2-polyn |
Configura on | ETS |
Gallu | 1 Uned dan do. |
Amodau Gosod | This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precau ons should always be taken to prevent electrosta c discharge to the unit. When working inside an enclosure (e.g., making adjustments, se ng switches, etc.), typical an -sta c precau ons should always be followed before touching the unit. |
Cydnawsedd Model AC | Hisense VRF systems |
Cynnwys y Cyflwyno | Intesis gateway and installa on manual. |
Heb ei gynnwys (yn y dosbarthiad) | Communica on cables. |
Mowntio | Mownt wal |
Deunyddiau Tai | Plas c |
Gwarant (blynyddoedd) | 3 mlynedd |
Deunydd Pacio | Cardbord |
Adnabod a Statws | |
ID Cynnyrch | INKNXHIS001R000 |
Gwlad Tarddiad | Sbaen |
Cod HS | 8517620000 |
Dosbarthiad Rheoli Allforio ar Rhif (ECCN) | EAR99 |
Nodweddion Corfforol | |
Cysylltwyr / Mewnbwn / Allbwn | KNX, porthladd HVAC, mewnbynnau deuaidd (cyswllt sych). |
Cyfarwyddiadau Defnydd
Amodau Gosod
This gateway is designed for indoor unit installation. Precautions should be taken to prevent electrostatic discharge when mounted outside an enclosure.
Cydweddoldeb
Yn gydnaws â systemau VRF Hisense.
Integreiddio Example
Refer to the provided installation manual for integration examples.
Defnydd Achos
Cwestiynau Cyffredin
Beth yw'r cyfnod gwarant ar gyfer y cynnyrch hwn?
Mae'r warant ar gyfer y rhyngwyneb Hisense-KNX yn 3 blynedd.
A ellir gosod y rhyngwyneb y tu allan i gaead?
If the unit is mounted outside an enclosure, precautions should always be taken to prevent electrostatic discharge.
Dogfennau / Adnoddau
![]() |
Rhyngwyneb KNX Intesis INKNXHIS001R000 gyda Mewnbynnau Deuaidd [pdfLlawlyfr Cyfarwyddiadau INKNXHIS001R000 Rhyngwyneb KNX gyda Mewnbynnau Deuaidd, INKNXHIS001R000, Rhyngwyneb KNX gyda Mewnbynnau Deuaidd, Rhyngwyneb gyda Mewnbynnau Deuaidd, Mewnbynnau Deuaidd |