KNX, ceiling PIR presence/absence detector

Warning icon Attention

To be installed by competent technician with good understanding of network devices.

Dimensions (mm)

CP electronics EBDSPIR-KNX Presence Detectors - Fig 1

Downloads and Videos

CP electronics EBDSPIR-KNX Presence Detectors - qr code

http://cpelectronics.co.uk/cp/686qr

Detection pattern

CP electronics EBDSPIR-KNX Presence Detectors - Fig 2

Wiring

CP electronics EBDSPIR-KNX Presence Detectors - Fig 3

Key

  1. Switches, as configured in the ETS software.
  2. Low voltage only.
  3. KNX bus

Presence or absence detection

The unit requires configuration by an appropriate software.
Absence detection activation and switches configurations are set using the ETS KNX software supplied by others.
It is designed to work with other KNX devices such as other detectors and switches from other manufacturers.

Presence & absence explain

CP electronics EBDSPIR-KNX Presence Detectors - qr code 2

http://cpelectronics.co.uk/cp/paqr

Installation

This device is designed to be flush ceiling-mounted.

  • Do not site the unit where direct sunlight might enter the sensor.
  • Do not site the sensor within 1m of any lighting, forced air heating or ventilation.
  • Do not fix the sensor to an unstable or vibrating surface.

Create cut out

CP electronics EBDSPIR-KNX Presence Detectors - Fig 4

Cut a 64mm diameter hole in the ceiling.

Wire in plugs & connect to detector

CP electronics EBDSPIR-KNX Presence Detectors - Fig 5

Wire in plug/s, using wiring diagram on page 2 as a guide. Connect the plug/s to the detector.

Clamp cable

CP electronics EBDSPIR-KNX Presence Detectors - Fig 6

Continue tightening the screws until the clamp bar snaps out and is tightly engaged against the cable/s. The cable clamp must clamp the outer sheath only.

Install detector

CP electronics EBDSPIR-KNX Presence Detectors - Fig 7

Warning icon Bend the springs up and push detector through hole in ceiling. When fully inserted the springs snap back to hold the device in place.
To avoid injury, take care when bending springs.

Technical Data

Part code EBDSPIR-KNX
Weight 0.150kg
Supply voltage DC 30 VDC over KNX bus
Current consumption 5.9mA
Terminal capacity KNX: 1.2mm² over KNX connector Switch input: 2.5mm²
Working temperature range -10 to 35ºC
Humidity 5 to 95% noncondensing
Material (casing) Flame retardant ABS and PC/ABS
Insulation class 2
IP rating 40
ComplianceCE SYMBOL EMC-2014/30/EU,
LVD-2014/35/EU

Accessories & associated products

Part Number Description
CP electronics EBDSPIR-KNX Presence Detectors - Fig 8 Extended wiring housing
CP electronics EBDSPIR-KNX Presence Detectors - Fig 9 Masking shields for EBDSPIR range
CP electronics EBDSPIR-KNX Presence Detectors - Fig 10 Compact, programming/commissioning handset
CP electronics EBDSPIR-KNX Presence Detectors - Fig 11 Compact, user handset
CP electronics logo CP Electronics
Brent Crescent, London NW10 7XR
t. +44 (0)333 900 0671
enquiry@cpelectronics.co.uk
CP electronics EBDSPIR-KNX Presence Detectors - symbol 1
www.cpelectronics.co.uk CP electronics EBDSPIR-KNX Presence Detectors - symbol 2
Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice.

WD686 Issue 8 Installation Guide, EBDSPIR-KNX
CP electronics EBDSPIR-KNX Presence Detectors - symbol 3

Documents / Resources

CP electronics EBDSPIR-KNX Presence Detectors [pdf] Installation Guide
EBDSPIR-KNX Presence Detectors, EBDSPIR-KNX, Presence Detectors, Detectors

References

Leave a comment

Your email address will not be published. Required fields are marked *