CLS RUBY COMPACT PENDANT SERIES
Manual V1.4 – December 2024
![]() |
![]() |
![]() |
![]() |
![]() |
Ceiling | 200 cm | 400 cm | ||
![]() |
![]() |
![]() |
![]() |
![]() |
600 cm | 800 cm | 1300 gr | ||
![]() |
![]() |
![]() |
![]() |
![]() |
50.000 h | 19º | 37º | 63º | High Power LED |
![]() |
![]() |
![]() |
![]() |
![]() |
IP20 | 2500K CRI>80 | 2700K CRI>80 | 2700K CRI>92 | 3000K CRI>92 |
![]() |
![]() |
![]() |
![]() |
![]() |
3500K CRI>92 | 4000K CRI>92 | RGBW W: (3000K) | RGBW W: (4000K) | RGBA |
![]() |
![]() |
![]() |
![]() |
![]() |
1800-400K | 2700-6500K | 1800-3000K | 200 ~ 240 VAC | Max. 30 Watt |
![]() |
![]() |
![]() |
![]() |
![]() |
Mains dimmable | 1-10V dimmable | |||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
SAFETY INFORMATION
![]() |
![]() |
![]() Do not stare into the LED |
![]() |
Qualified technician
|
Disconnect the power supply before installing or maintaining |
Make sure all connectors are connected properly | Use a source of AC power that complies to local electrical codes | Block access below the work area when maintaining the unit |
Don’t modify or install genuine parts on this product | Don’t install in a flammable or explosive area | Warning! Some surfaces can be hot |
CONTENT
TECHNICAL
Tools
SPECIFICATIONS
LED: | High Power LED |
Available colours: | CRI>80: 2500K & 2700K CRI>92: 2700K, 3000K, 3500K or 4000K |
Colour Changing: | RGBA, RGBW (W: 3000K) or RGBW (W: 4000K) |
Tunable White: | 1800K-4000K or 2700K-6500K |
Dim To Warm: | 1800K-3000K |
Lenses: | 19º, 37º or 63º |
Power supply: | 200 ~ 240 VAC |
Power consumption: | 6 serie: Max. 30 Watt |
Housing: | Anodised aluminium black or white coated |
Weight: | 1300 gr |
IP value: | IP20 |
Cable length: | 200, 400, 600 or 800 centimeters |
Measurements: | 232 x 100 mm (hxø) |
Ambient temperature: | -10º C till +40º C |
ACCESSORIES
Y106017 | CLS Magnet for programming, 5 pcs |
122200 | CLS D-ta DMX addresser |
INSTALLATION
a) Power cable fitted with integrated safety cable
a) Make sure that the safety hook can carry the weight of the Ruby
a) Brown cable
b) Yellow/green
c) Blue cable
a) Tighten
INSTALLATION DMX VERSION
a) 5 core combi cable fitted with intergrated safety cable
a) Make sure that the safety hook can carry the weight of the Ruby
L = Brown cable
= Yellow/green
N = Blue cable
DMX + = Red cable
DMX – = White cable
(4) 5 core combi cable connection scheme
See step 6 for the ammount of Ruby’s per switch-on
a) Tighten
(6) Maximum amount of Ruby’s per switch-on *
5 serie – 22 Watt: 25 pieces
6 serie – 30 Watt: 25 pieces
7 serie – 45 Watt: 5 pieces
8 serie – 60 Watt: 5 pieces
9 serie – 110 Watt: 5 pieces
* Due the switch-on peak
PROGRAMMING DMX
All settings can be configured via DMX. Settings can be configured at once or separately. When one or a couple settings needs to be changed just leave all other setting values zero. This keeps those settings unchanged. Please check the table for more
information.
Always use a DMX controller with digital interface. If not available, you can purchase the CLS D-ta DMX addresser unit (#122200).
First make sure to set the DATA on the DMX controller. To program the setting into the LED fixture follow the next steps.
a) Place magnet on the indication mark. The LEDs will light up
b) After 2 seconds
The LED’s will flash 3 times confirming storage*
* If all LEDs flash 10 times, something went wrong. Please try again. If the problem continues to occur, please contact your local sales distributor.
WIRELESS DMX
See the Manual of Wireless Solutions. The Manual can be found on our CLS website, in the Downloads section. Or use the link below https://www.cls-led.com/wp-content/uploads/cls-files/W-DMX-manual.pdf
Unlink procedure
When the fixture does not receive a DMX signal (DMX controller off), place the magnet on the bottom of the fixture for 5 seconds.
Slow flash indicates that the fixture is unlinked.
BLUETOOTH BY CASAMBI
For Casambi controlled fixtures, see the manual of Casambi. The Manual can be found on our CLS website, in the Downloads section.
Or use the link below:
https://www.cls-led.com/wp-content/uploads/cls-products/CLS_CASAMBI/MANUAL/Manual_Casambi_controlsystem_EN.pdf
PROGRAMMING TABLE
PROGRAMMING TABLE | ||||
DMX | Function | Data | Parameters | Description |
CH1 | Set address 001 to 255 | 0 | 0 = no change * | Use this DMX channel to set address from 001 to 255. The configured DMX address is called “n” |
1…255 | DMX address = 1…255 | |||
CH2 | Set address 256 to 508 | 0 | no change | Use this DMX channel to set address from 256 to 508. The configured DMX address is called “n” |
1…255 | DMX address = 256…508 | |||
CH3 | Static behavior | 0 | no change | If no DMX is present the fixture will respond like set in this function. |
1 | last DMX value * | |||
2 | output off | |||
3 | load static values | |||
CH4 | Soft dim | 0 | no change | When dynamic softdim is activated an extra DMX channel behind the colours and/or Master controls the soft dim reaction. If fixed no extra DMX channel is used. |
1 | off * | |||
2 | dynamic | |||
3-250 | fixed interpolation delay | |||
CH5 | Master control | 0 | no change | If master is first channel is selected the channel will be DMX channel “n”. If master is last channel is selected the channel will be “n+x” (“x” is calculated in the output patch). |
1 | no master used * | |||
2 | master is first channel | |||
3 | master is last channel | |||
CH6 | Output 1 patch | 0 | no change | Each output channel can be patched to respond to the desired DMX channel. This enables the user to mix up the colours according to the controller that is used.Example: all outputs are patched as 1 All outputs will be controlled by DMX channel “n”. If master is used total DMX channels will be 2 otherwise it uses 1 channel (“x” = 1).Example: output 1&2 are patched as 1 and 3&4 are patched as 2 Output 1&2 will be controlled by DMX channel “n”. Output 3&4 will be controlled by DMX channel “n+1”. If master is used total DMX channels will be 3 otherwise it uses 2 channels (“x” = 2). |
1 | DMX channel n | |||
2 | DMX channel n+1 | |||
3 | DMX channel n+2 | |||
4 | DMX channel n+3 | |||
CH7 * | Output 2 patch | 0 | no change | |
1 | DMX channel n | |||
2 | DMX channel n+1 | |||
3 | DMX channel n+2 | |||
4 | DMX channel n+3 | |||
CH8 * | Output 3 patch | 0 | no change | |
1 | DMX channel n | |||
2 | DMX channel n+1 | |||
3 | DMX channel n+2 | |||
4 | DMX channel n+3 | |||
CH9 * | Output 4 patch | 0 | no change | |
1 | DMX channel n | |||
2 | DMX channel n+1 | |||
3 | DMX channel n+2 | |||
4 | DMX channel n+3 | |||
CH10 | Static output 1 | 0 | no change | Each output channel can be set to a static intensity.
If no DMX is present and Static behavior is set to “load static values”. The outputs will be set to the configured intensity values. |
1 | output off | |||
2…255 | intensity 2…255 *(255) | |||
CH11 * | Static output 2 | 0 | no change | |
1 | output off | |||
2…255 | intensity 2…255 *(255) | |||
CH12 * | Static output 3 | 0 | no change | |
1 | output off | |||
2…255 | intensity 2…255 *(255) | |||
CH13 * | Static output 4 | 0 | no change | |
1 | output off | |||
2…255 | intensity 2…255 *(255) | |||
CH14 * | Load default settings | 0 | no change | This function resets all settings to the Factory setting. |
1 | load Factory settings | |||
CH15 | Input Resolution setting | 0 | no change | In 16 bit mode 2 channels are used per colour. First channel is rough channel, second channel fine. 16 bit mode is only available in DRIVE mode 2. |
1 | 8 bit * | |||
2 | 16 bit | |||
CH16 | Drive mode setting | 0 | no change | You can set the frequency of the PWM for best compatibility with Camera Systems. However, the highest resolution of the dimming curve will be at the lowest frequency. Option 1 can be used to be compatible with older installation and new fixtures. |
1 | compatible with version < 2020 | |||
2 | PWM frequency 0.7kHz * | |||
3 | PWM frequency 1.4kHz | |||
4 | PWM frequency 2.8kHz | |||
5 | PWM frequency 5.6kHz |
* Default setting CHXX* Not applicable on the Ruby DMX single colour
REFLECTOR REPLACEMENT
a) Make sure the indicated holes falls over the clips
2024 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. No part of this manual may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/General-Terms.pdf
HONEYCOMB ASSEMBLY
a) Make sure the honeycomb is placed between the diffuser & frontring
LIST OF SYMBOLS
Protection class
One, two or three
Application area
Indoor or outdoor
Application area
Floor, wall or ceiling
Swivel
Fixture is horizontally rotatable, indicated in degrees
Swivel
Fixture is vertically rotatable, indicated in degrees
Multiple connection
Daisychain connectivity
Installation depth
In centimeters
Installation size
In centimeters
Cable length
Maximum cable attached to the fixture in centimeters
Driver
Inclusive or exclusive
Internal or external
Weight
In grams/kilograms
Pressure
Maximum pressure on the fixture in kg/cm²
Lifespan
Of the light source in hours
Lenses
Availble lenses, indicated in degrees
Performance Zoom
Adjustable beam angle
LEDs
Kind of LED used in the fixture
Plug & play
Easy connection using the SmartConnect system
IP value
Ingress Protection classifies the degrees of protection provided against the intrusion of the product
Colour changing
RGB, RGB-W, RGB-A, AWB or Tunable White
Retail & Food LED modules
Clothing, furniture, kitchens, jewellery, shoes, bread, meat, fish and vegetables & fruit.
Colour
Available colours;
Amber, blue, red or green
White colour temperature
In different Kelvin values;
Cold white, neutral white, warm white or extra warm white
Curve
Minimal bending curve in centimeters
Cutting length
Indicated by the cutting marks
LED pitch
Pitch between the LEDs in millimeters
Power supply
In VDC, VAC or milliAmpere
Power consumption
In VA or Watt
Dimmable
1-10 Volt, Phase, individual, DMX dimmable or DALI
PWM dimming
Traditional PWM dimming, DMX analog or DMX Hybrid dim
Bluetooth controlled
By Casambi
Magno dimming
Accurate dimming from 100 – 1% by using a magnet
Dynamic Control
Dynamic Power Control or Dynamic Temperature Control
DMX input
Fixture works on DMX512 protocol or Wireless DMX
Combined product
Compose your own fixture
Warranty
3 or 5 years warranty on the product
Conformité Européenne
CE marking for free marketability of industrial goods within the EU
Energy label
Lightsource
Equipped with a CLS, Bridgelux or a Xicato LED module
Documents / Resources
![]() |