EDA-logo

ED-PAC3020 EDATEC Industrial Automation and Controls

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-PRODUCT

Mga detalye

  • Ngalan sa Produkto: ED-PAC3020
  • Manufacturer: EDA Technology Co., Ltd
  • Petsa sa Pagpagawas: Agosto 1, 2025
  • Programming Software: CODESYS V3.5 SP19
  • Mga Pag-configure sa Memorya: 2GB DDR + 128GB SSD or 8GB DDR + 256GB SSD
  • Mga Interface: HDMI, USB, Ethernet, RS232, RS485

Mga Instruksyon sa Paggamit sa Produkto

  1. Tapos naview:
    1. The ED-PAC3020 is a real-time CODESYS programmable automation controller suitable for industrial control and IoT fields. It comes pre-installed with a multi-core CODESYS runtime and offers different memory configurations based on user requirements.
  2. Hardware:
    1. The device features commonly used interfaces such as HDMI, USB, Ethernet, RS232, and RS485. It integrates an RTC and supports connection to remote EtherCAT-based I/O modules.
  3. Introduction to CODESYS Software:
    1. The product supports CODESYS V3.5 SP19 and later versions for programming and control.
  4. Aplikasyon sa Networking:
    1. The device offers EtherCAT, Ethernet, RS485, and RS232 interfaces for multi-layer network communication to meet diverse application requirements.

Front Panel:

  1. RS232 port: Gigamit sa pagkonektar sa third-party control equipment.
  2. Green UART indicators: Check the communication status of UART port.
  3. Pula nga timailhan sa gahum: Nagpakita sa kahimtang sa gahum sa aparato.
  4. Green system status indicator: Shows system read/write operations status.
  5. Audio Output (HPO): Stereo audio output.
  6. Audio Input (LINE IN): Nagsuporta sa stereo audio input.
  7. RS-485 port: Used to connect third-party control equipment.
  8. USB 2.0 ports: Nagsuporta hangtod sa 480Mbps transmission rate.

Manwal sa Hardware

  • Kini nga kapitulo nagpaila sa produkto sa ibabawview, CODESYS software, networking application, packaging list, hitsura, butones, indicators ug interface.

Tapos naview

  • The ED-PAC3020 is a real-time CODESYS programmable automation controller, pre-installed by default with a multi-core CODESYS runtime. Depending on the application scenario and user requirements, it offers programmable logic system configurations with either 2GB DDR + 128GB SSD or 8GB DDR + 256GB SSD.

WARNING

  • The ED-PAC3020 device comes pre-installed with a valid CODESYS license by default. Reinstalling the operating system will invalidate the CODESYS license. Do not attempt to install the OS on your own.
  • Ang ED-PAC3020 naghatag ug kasagarang gigamit nga mga interface sama sa HDMI, USB, Ethernet, RS232, ug RS485, nag-integrate sa RTC, ug panguna nga gigamit sa kontrol sa industriya ug IoT nga mga natad.
  • The ED-PAC3020 supports connection to remote EtherCAT-based I/O modules (e.g., couplers, DI, DO, AI, AO) via an EtherCAT network.
  • The device integrates the CODESYS Control Runtime System, supporting IEC 61131-3 programming standards and industrial communication protocols like EtherCAT and Modbus TCP.

Users can optionally enable additional functionalities by licensing features such as:

  • TargetVisu
  • WebVisu Softmotion
  • CNC + Robotics
  • EtherCAT Master
  • Modbus TCP Master
  • OPC UA ServerED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-1

Anaa ang mga pasadya nga pag-configure aron matubag ang piho nga mga kinahanglanon sa aplikasyon.

Introduction to CODESYS Software

  • CODESYS (Controller Development System) is an open industrial automation software development platform that provides a full-stack solution for programming, debugging, and maintaining programmable logic controllers (PLCs), industrial PCs (IPCs), and embedded control systems.
  • Compliant with the IEC 61131-3 international standard, it supports complex logic control, multi-axis motion control, industrial communication protocol integration, and real-time data processing.
  • It is widely used in smart manufacturing, energy management, logistics automation, and other industrial fields.

Pangunang mga bahin sa CODESYS:

  • Standardized Programming Language Support
    • Full compatibility with the IEC 61131-3 programming languages:
      • Ladder Diagram (LD)
      • Function Block Diagram (FBD)
      • Structured Text (ST)
      • Listahan sa Instruksyon (IL)
      • Sequential Function Chart (SFC)
    • Supports Object-Oriented Programming (OOP) extensions for large-scale complex projects.
  • Cross-Platform Development & Deployment
    • Development Environment: Compatible with Windows and Linux operating systems, offering a unified engineering interface.
    • Target Systems: Deployable on 2,000+ industrial controller hardware platforms, including ARM/X86 architectures.
  • Modular Engineering Libraries
    • Prebuilt Libraries: Include industrial protocol stacks (Modbus/TCP, OPC UA, EtherCAT) and advanced control modules (PID control, CNC interpolation algorithms).
    • Custom Libraries: Support encapsulation and reuse of Function Blocks and POUs (Program Organization Units).
  • Visual Debugging & Diagnostic Tools
    •  Real-time monitoring of variables, I/O mapping, and task execution status with waveform analysis.
    • Advanced debugging tools: breakpoints, step-by-step execution, and cross-referencing for rapid fault diagnosis.
    • Integrated HMI development tools for seamless SCADA system integration.
  • Ang ED-PAC3020 nagsuporta sa CODESYS V3.5 SP19 ug sa ulahi nga mga bersyon.

Aplikasyon sa Networking

  • The ED-PAC3020 features EtherCAT, Ethernet, RS-485 and RS-232 interfaces, enabling multi-layer network communication to meet diverse application requirements across various scenarios. A typical application topology is illustrated in the figure below:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-2

Listahan sa pagputos

  • 1 x ED-PAC3020 Unit
  • 4 x Pads

Panagway

  • Introducing the functions and definitions of the interfaces on each panel.

Front Panel

Pagpaila sa mga tipo sa interface sa atubangan nga panel ug mga kahulugan.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-3

DILI. Kalihokan Kahubitan
  1 x RS232 port, 3-Pin 3.5mm pitch phoenix terminal, which is used to connect the third-party control

kahimanan.

2 2 x berde nga mga indikasyon sa UART, nga gigamit aron masusi ang kahimtang sa komunikasyon sa pantalan sa UART.
3 1 x pula nga indikasyon sa gahum, nga gigamit aron masusi ang kahimtang sa power-on ug power-off sa aparato.
4 1 x green system status indicator, nga gigamit sa view ang kahimtang sa sistema sa pagbasa/pagsulat nga mga operasyon.
5 1 x Audio Output (HPO), 3.5mm audio jack connector (berde), stereo audio output.
6 1 x Audio Input (LINE IN), 3.5mm audio jack connector (pula), pagsuporta sa stereo audio input.
 

7

1 x RS485 port, 3-Pin 3.5mm pitch phoenix terminal, nga gigamit sa pagkonektar sa third-party control equipment.
8 2 x USB 2.0 port, Type-A connector, ang matag channel nagsuporta hangtod sa 480Mbps transmission rate.
9 2 x USB 3.0 port, Type-A connector, ang matag channel nagsuporta hangtod sa 5Gbps transmission rate.
 

10

1 x Ethernet interface (10/100/1000M auto-negotiation), RJ45 connector, EtherCAT communication interface for connecting to EtherCAT networks, with PoE (Power over Ethernet) support.

Likod nga Panel

  • Pagpaila sa mga tipo ug mga kahulugan sa interface sa likod nga panel.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-4
DILI. Kalihokan Kahubitan
1 1 x power button, nga gigamit sa pag-on ug pagpalong sa device.
 

 

2

1 x Micro SD card slot, gitagana alang sa umaabot nga paggamit.

Mubo nga sulat: Ang device nag-boot gikan sa SSD pinaagi sa default. Kini nga Micro SD card slot gitagana alang sa potensyal pagpalapad.

Side Panel

  • Pagpaila sa mga tipo sa interface sa side panel ug mga kahulugan.

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-5

DILI. Kalihokan Kahubitan
1 1 x DC input, USB Type-C connector, nga nagsuporta sa 5V 5A power input.
2 2 x HDMI port, Micro HDMI connector, nga makakonektar sa usa ka display ug mosuporta sa 4K 60Hz

Butang

  • The ED-PAC3020 includes a ON/OFF button, and the silkscreen is “ON/OFF”. If you run Raspberry Pi Desktop, you can initiate a clean shutdown by briefly pressing the power button. A menu will appear asking whether you want to shutdown, reboot, or logout.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-6

TIP

  • Kung nagpadagan ka sa Raspberry Pi Desktop, mahimo nimong i-press ang power button kaduha sa dali nga sunud-sunod aron masira.

Timailhan

  • Kini nga seksyon nagpatin-aw sa kahimtang ug mga kahulugan sa mga timailhan nga gisagol sa ED-PAC3020 nga aparato.
​Indicator Status Deskripsyon
 

 

 

PWR

On Gipaandar na ang device.
 

Blink

Power supply of the device is abnormal, please stop the power supply immediately.
Off Wala gipaandar ang device.
 

BUHAT

 

Blink

Ang sistema malampuson nga nagsugod ug nagbasa ug nagsulat sa datos.
​Indicator Status Deskripsyon
   

Off

The device is not powered on or does not read and write data.
COM1~COM2 On/Blink Gihatud ang datos
 

Off

The device is not powered on or there is no data transmission.
Yellow indicator of Ethernet port On Ang koneksyon sa Ethernet anaa sa normal nga kahimtang.
Blink Ang koneksyon sa Ethernet dili normal.
Off Ang koneksyon sa Ethernet wala ma-set up.
Green nga timailhan sa Ethernet port On Ang koneksyon sa Ethernet anaa sa normal nga kahimtang.
Blink Ang datos gipasa pinaagi sa Ethernet port.
Off Ang koneksyon sa Ethernet wala ma-set up.

TIP

  • Ang function sa PWR/ACT indicator sa Raspberry Pi 5 gibalhin na ngadto sa separado nga PWR ug ACT indicators pinaagi sa default, mao nga ang PWR/ACT indicator magpabilin human ma-on ang device.

Interface

  • Pagpaila sa kahulugan ug function sa matag interface sa produkto.

Gahum Interface

  • Ang ED-PAC3020 device naglakip sa usa ka power input interface, nga naggamit ug USB Type-C connector nga gimarkahan og "PWR IN" ug nagsuporta sa 5V 5A power input.

TIP

  • Aron makab-ot sa Raspberry Pi 5 ang mas maayo nga pasundayag, girekomenda nga mogamit usa ka 5V 5A power adapter.
  • 1.8.2 1000M Ethernet Interface (EtherCAT)
  • The ED-PAC3020 device includes one auto-negotiating 10/100/1000M Ethernet interface with an RJ45 connector featuring status LEDs, labeled as ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-7“. This interface serves as an EtherCAT communication port for connecting to EtherCAT networks and supports PoE (Power over Ethernet) power delivery.

HDMI Interface

  • Ang ED-PAC3020 device naglakip sa 2 HDMI interface gamit ang Micro HDMI connectors, gimarkahan nga "HDMI", para sa pagkonektar sa HDMI display. Kini nga mga interface nagsuporta sa video output hangtod sa 4Kp60.

TIP

  • Some third-party Micro HDMI cables may have shorter Micro HDMI connectors, which could cause connection issues. It is recommended to use the official Raspberry Pi Micro HDMI to Standard HDMI cable for optimal compatibility.

USB 2.0 Interface

  • The ED-PAC3020 device includes 2 USB 2.0 interfaces with standard Type-A connectors, labeled as “ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-8“. These interfaces support connecting standard USB 2.0 peripherals and offer a maximum transfer rate of 480Mbps.

USB 3.0 Interface

  • The ED-PAC3020 device includes 2 USB 3.0 interfaces with standard Type-A connectors, labeled as “ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-9 “. These interfaces support connecting standard USB 3.0 peripherals and offer a maximum transfer rate of 5Gbps.

Taliwala sa RS232

  • The ED-PAC3020 device includes 1 RS232 interface with a 3-Pin 3.5mm pitch Phoenix terminal, labeled “TX/RX/GND”.

Kahulugan sa Pin

  • Terminal pins are defined as follows:
ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-10

 

Pin ​ID Ngalan sa Pin
1 TX
2 RX
3 GND

Ang interface sa RS232 katumbas sa mosunod nga mga ngalan sa pin sa Pi5:

Signal Pi5 GP​IO Name Pi5 Pin gawas
TX GPIO4 UART3_TXD
RX GPIO5 UART3_RXD

Ang RS232 wiring schematic mao ang mosunod:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-11

Taliwala sa RS485

  • The ED-PAC3020 device includes 1 RS485 interface with a 3-Pin 3.5mm pitch Phoenix terminal, labeled “A/B/GND”.

Kahulugan sa Pin

  • Terminal pins are defined as follows:
ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-12

 

Pin ​ID Ngalan sa Pin
1 A
2 B
3 GND

Ang interface sa RS485 katumbas sa mosunod nga mga ngalan sa pin sa Pi5:

Signal Pi5 GP​IO Name Pi5 Pin gawas
A GPIO12 UART5_TXD
B GPIO13 UART5_RXD

Pagdugtong nga mga Kable

  • Ang RS485 wiring schematic mao ang mosunod:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-13

RS485 Pagtapos sa Resistor Configuration

  • The ED-PAC3020 device includes 1 RS485 interface.
  • A 120Ω termination resistor is reserved between the A and B lines of the RS485 circuit. Inserting a jumper cap enables this termination resistor.
  • By default, no jumper is installed, rendering the 120Ω termination resistor inactive. The termination resistor is located at J7 on the PCBA (printed circuit board assembly).

TIP

  • The device case must be opened to inspect the 120Ω termination resistor.

Audio Input

  • Ang ED-PAC3020 device naglakip sa 1 audio input interface (LINE IN), usa ka pula nga 3.5mm audio jack, nga gimarkahan nga "", nga nagsuporta sa stereo input.

Audio Output

  • The ED-PAC3020 device includes 1 audio output interface (HPO), a green 3.5mm audio jack, labeled as ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-14“, which supports stereo output.

Pag-instalar sa Device

  • Ang ED-PAC3020 device gidisenyo alang sa desktop placement pinaagi sa default ug nagsuporta sa wall mounting gamit ang opsyonal nga ED-ACCBKT-L3020 wall-mount bracket gikan sa among kompanya.

TIP

  • The ED-PAC3020 packaging box does not include the ED-ACCBKT-L3020 by default. Users must purchase it separately.

Pagpangandam:

  • Prepared a Phillips-head screwdriver.
  • Obtained the ED-ACCBKT-L3020 wall-mount bracket.

Lakang:

  1. Use a Phillips screwdriver to unscrew the four M2.5 screws on the side of the ED-IPC3020 counterclockwise.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-15
  2. Align the left and right brackets of the ED-ACCBKT-L3020 with the screw holes on both sides of the ED-PAC3020, insert the four M2.5*6 screws, and tighten them clockwise with a Phillips screwdriver to secure the ED-ACCBKT-L3020 to the sides of the ED-PAC3020.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-16
  3. Based on the spacing and diameter of the wall-mounting screw holes of the ED-ACCBKT-L3020 left and right brackets (refer to the diagram below), drill holes in the wall accordingly, then proceed with wall-mounted installation of the device.
    Yunit: mm
  4. Tolerance: 0.5-6±0.05, 6-30±0.1, 30-120±0.15

Dimensyon

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-17

Pag-boot sa Device

  • Kini nga kapitulo nagdetalye sa piho nga mga pamaagi sa pagkonektar sa mga kable ug pagpaandar sa device.

Pagdugtong nga mga Kable

  • This section describes the procedures for connecting cables to the device.

Pagpangandam:

  • Obtained fully functional accessories such as a switch, monitor, mouse, keyboard, I/O expansion module, and power adapter.
  • Available functional network connection.
  • Available functional cables: HDMI cable and Ethernet cable.

Schematic diagram sa pagkonektar sa mga kable:

  • Please refer to 1.8 Interface for the pin definition of each interface and the specific method of wiring.

TIP

  • Some third-party Micro HDMI cables may have shorter Micro HDMI connectors, which could cause connection issues. It is recommended to use the official Raspberry Pi Micro HDMI to Standard HDMI cable for optimal compatibility.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-18

Pag-boot sa Sistema Sa Unang Higayon

  • Once the ED-PAC3020 is connected to power, the system will begin to boot up.
  • Red PWR indicator: Lights up to indicate the device is receiving power.
  • Green ACT indicator: Blinks to signal normal system startup. The Raspberry Pi logo will then appear in the upper-left corner of the screen.

TIP

  • The default username is pi, the default password is raspberry.

Raspberry Pi OS (Desktop)

  • Kung ang aparato na-install sa pabrika sa Desktop OS, direkta kini nga mag-boot sa interface sa desktop sa pagsugod, ingon sa gipakita sa numero sa ubos.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-20

Raspberry Pi OS (Lite)

  • Kung ang aparato na-install sa pabrika sa Lite OS, awtomatiko kini nga mag-log in gamit ang default nga mga kredensyal pagkahuman sa pagsugod. Ang numero sa ubos nagpakita nga ang sistema malampuson nga nag-boot.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-21.

CODESYS Programming

  • Kini nga kapitulo nagdetalye sa piho nga mga operasyon nga nalangkit sa paggamit sa CODESYS.

WARNING

  • The ED-PAC3020 device comes pre-installed with a valid CODESYS license by default. Reinstalling the operating system will invalidate the CODESYS license. Do not attempt to install the OS on your own.
  • CODESYS Software Download and Installation

TIP

  • The installed CODESYS IDE version must be 3.5.19 or higher, and the PC operating system must be Windows 10 or Windows 11 (64-bit recommended).
  • Download the installation package from the official CODESYS website. Ang pag-download URL is https://store.codesys.com/de/ (https://store.codesys.com/de/).
  • TIP
  • When downloading from the CODESYS official website sa unang higayon, kinahanglan una kang magparehistro ug mag log in sa imong account.
  • Right-click the downloaded installer and select “Run as administrator” from the context menu. Click “Install” in the opened installation interface, and keep the default configuration during the installation process.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-22
  • After the installation is complete, click “Finish” to close the installation interface.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-23

Obtaining and Installing Device Description File

  • Sa dili pa magkonektar sa device pinaagi sa CODESYS, kinahanglan nimo nga i-download ug i-install ang paghulagway sa device file una.

Obtaining Device Description File

TIP

  • The device’s default Ethernet port IP address is 192.168.0.100. To modify it, refer to Configuring Ethernet IP.

Pagpangandam:

  • A CODESYS-authorized ED-PAC3020 is available.
  • A functional Ethernet cable is available.
  • A Windows PC is prepared, with its IP address configured to the same subnet as the device. For exampug, kung ang IP sa device (1000M Ethernet port) kay 192.168.0.100 , ibutang ang IP sa PC sa 192.168.0.99 .

Mga lakang:

  1. Connect the device’s Ethernet port to the PC via an Ethernet cable, then power on the device.
  2. Enter http://192.168.0.100:8100 in the PC’s web browser aron ma-access ang interface nga "PLC Setting".
  3. In the “Device Info” section, click the “[Download] Device Description File” button to download the corresponding “.xml” format device description file.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-24

TIP

  • Also available directly in the document ED-PAC3020 Device File (https://vip.123pan.cn/ 1826505135/17964309) .

Installing Device Description File

Pagpangandam:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
  • An ED-PAC3020 device with a valid CODESYS license and its corresponding device description file.
  • Connect both the PC and ED-PAC3020 to the network, ensuring their IP addresses are within the same subnet.

Mga lakang:

  • Double-click the CODESYS icon on the PC desktop to open the CODESYS software. From the menu bar, select “Tools” → “Device Repository”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-25
  • In the opened “Device Repository” pane, click “Install”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-26
  • In the pop-up “Install Device Description” pane, select the device description file aron ma-install ug i-klik ang "Bukas" aron ipadayon ang pag-install.
  • After successful installation, you can verify in the “Device Repository” that the device description file malampuson nga nadugang.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-27

Installing Remote I/O Device Description File

Pagpangandam:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
  • An ED-PAC3020 device with a valid CODESYS license.
  • The remote I/O device description files na-download gikan sa: Remote I/O Deskripsyon Files (https://vip.123pan.cn/1826505135/16632390).
  • Connect the PC, ED-PAC3020, and remote I/O devices to the same switch. Ensure that the IP addresses of the PC, ED-PAC3020, and remote I/O devices are within the same subnet.

Mga lakang:

  1. Double-click the CODESYS icon on the PC desktop to open the CODESYS software. From the menu bar, select “Tools” → “Device Repository”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-28
  2. In the opened “Device Repository” pane, click “Install”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-29
  3. In the pop-up “Install Device Description” pane, select the I/O device decirption file aron ma-install ug i-klik ang "Bukas" aron ipadayon ang pag-install.
  4. After successful installation, you can verify in the “Device Repository” that the I/O device description file malampuson nga nadugang.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-30

Pag-configure sa Hardware

Pagpangandam:

  • A PC installed with CODESYS software version V3.5 SP19 (64-bit).
    • Deskripsyon sa aparato files ug hilit nga I/O device nga paghulagway files have been installed. Connect the PC, ED-PAC3020, and remote I/O devices to the same switch. Ensure that the IP addresses of the PC, ED-PAC3020, and remote I/O devices are within the same subnet.

Create a New Project and Connect to the Device

Mga lakang:

  • Power on the ED-PAC3020 and the remote I/O modules. Open the CODESYS software on the PC, select “File” → “New Project” in the menu bar to open the “New Project” pane, and create a standard project.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-31
  • Select the installed device description file ug i-klik ang "OK".ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-32
  • Double-click the device, select “Scan Network” on the right, then choose the detected device from the scan results, and click “OK” to confirm.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-33

TIP

  • If the device cannot be detected during scanning, manually enter the IP address in the target device settings to connect.
  • If a device login prompt appears, log in with your credentials (username and password) or follow the instructions to register a new account.\

As shown in the figure below, this indicates the device is successfully connected.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-34

Adding Remote I/O Modules

Mga lakang:

  1. Right-click “Device” and select “Add Device” in the menu to add the EtherCAT Master.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-35
  2. Double-click on the EtherCAT Master device to set the source address (Select the EtherCAT port, which corresponds to the device’s eth0 port).ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-36
  3. I-klik ang ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-38 button to log in to the device. A successful login is shown in the figure below.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-37
  4. Click on the EtherCAT Master device, select “Scan for Devices” in the right-click menu, and copy all devices to the project after scanning is completed.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-39
  5. I-klik ang ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-40button to log out of the device.
  6. Double-click the slave device, configure the relevant parameters in the right-hand interface, enable “Expert settings”, select “Enable” under Select DC section, and select “Enable Sync0”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-41
  7. I-klik ang ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-38 button to download the program to the device, then click the  button to run it. As ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-60shown in the figure below, this indicates a successful operation.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-42

Pagprograma

  • Ang mosunod nga exampGipakita ni le ang praktikal nga pagprograma gamit ang usa ka piho nga senaryo sa coding.

Proseso sa Programa

ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-43

Ang Programming Halample

  • Complete the development and debugging of a program for a timed blinking LED using a PNP-type 8-channel digital output (DO) module.

Pagpangandam:

  • A standard project has been created.
  • Hardware configuration has been completed.
  • A 24V compact LED lamp has been connected to the first output port of the remote DO (Digital Output) module.

Mga lakang

  • Double-click the DO module, select “Module I/O Mapping” → “Output” in the right-hand interface, and view ang mga adres sa tanang output port. Sama sa gihulagway sa ubos, ang address sa unang output port mao ang %QX18.0 .ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-44
  • Write the program code as follows:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-46 ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-47 ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-48
  • After completing the program, click ” ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-61” to compile it and ensure there are no errors.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-49
  • Click Login to download the program to the device, then click Run to observe the LED blinking every 0.5 seconds.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-50

Operasyon ug Pagmentinar

  • Human ma-download ang programa sa device, mahimo nimong buhaton ang Run and Stop operations.
Status Mga operasyon
Pagdagan nga Programa In the main menu of the software interface, click the Login  button.
Hunong ang Programa In the main menu of the software interface, click the stop  button.

Pag-configure sa Sistema

  • Kini nga kapitulo nagpaila kon unsaon pag-configure ang sistema.

WARNING

  • The ED-PAC3020 device comes pre-installed with a valid CODESYS license by default. Reinstalling the operating system will invalidate the CODESYS license. Do not attempt to install the OS on your own.
  • Pagpangita IP sa Device
  • Layo nga Login
  • Pag-configure sa Wi-Fi
  • Pag-configure sa Ethernet IP
  • Configuring Bluetooth.
  • Pag-configure sa Buzzer
  • The buzzer is controlled using GPIO6.
  • Execute the following command to turn on the buzzer:ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-51
  • Pag-configure sa RTC
  • Pag-configure sa Serial Port
  • Kini nga kapitulo nagpaila sa pamaagi sa pag-configure sa RS232 ug RS485.

Installing Picocom Tool

  • In the Linux environment, you can use the picocom tool to debug the serial ports RS232 and RS485.
  • Execute the following command to install the picocom tool.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-52
  • 5.8.2 Pag-configure sa RS232
    Ang ED-PAC3020 adunay 1 RS232 interface, ug ang katugbang nga COM port ug device niini files gilista sa lamesa sa ubos:
Numero of RS485 Mga pantalan Katugbang COM Dunggoanan Katugbang Device File
1 COM2 /dev/com2
  • Input commands as needed to control external device.

Configuring RS485

  • The ED-PAC3020 contains 1 RS-485 interface, and its corresponding COM port and device files gilista sa lamesa sa ubos:
Numero of RS485 Mga pantalan Katugbang COM Dunggoanan Katugbang Device File
1 COM2 /dev/com2

Pagpangandam:

The RS485 ports of ED-PAC3020 has been connected with external device. Steps:

  1. Execute the following command to open the serial port com2, and configure the serial port baud rate to 115200.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-53
  2. Input commands as needed to control external device.

Pag-configure sa Audio

  • Pag-configure sa Audio
  • CODESYS License Management
  • Ang ED-PAC3020 device nag-una nga na-install nga adunay lisensya sa CODESYS nga default. Mahimo nimong i-back up ug ibalik ang lisensya pinaagi sa pag-access sa interface nga "PLC Setting".

License Backup
Pagpangandam:

  • A Windows PC has been set up with an IP address in the same subnet as the device. For exampug, kung ang IP sa device (1000M Ethernet port) kay 192.168.0.100 , ibutang ang IP sa PC sa 192.168.0.99 .
  • A functioning Ethernet cable has been prepared.

Mga lakang:

  • Connect the device’s 1000M Ethernet port to the PC via an Ethernet cable, then power on the device.
  • Enter http://192.168.0.100:8100 in the PC’s web browser aron ma-access ang interface nga "PLC Setting".
  • In the “Codesys License Management” interface, click “Backup License” to download the license file ug i-save kini sa lokal.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-56

TIP

  • The backed-up license file mahimo ra ibalik sa parehas nga aparato.

License Restore

Pagpangandam:

  • A Windows PC has been set up with an IP address in the same subnet as the device. For exampug, kung ang IP sa device (1000M Ethernet port) kay 192.168.0.100 , ibutang ang IP sa PC sa 192.168.0.99 .
  • A functioning Ethernet cable has been prepared.
  • The backed-up license file nakuha na.

Mga lakang

  1. Connect the device’s 1000M Ethernet port to the PC via an Ethernet cable, then power on the device.
  2. Enter http://192.168.0.100:8100 in the PC’s web browser aron ma-access ang interface nga "PLC Setting".
  3. In the “Codesys License Management” interface, click “Restore License”.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-57
  4. As prompted, select the obtained license file under a custom path.
  5. After a successful License Restore, a 100% progress bar will be displayed in the right-hand panel.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-58
  6. Open the device’s terminal command pane, execute the following command, and restart the device.ED-PAC3020-EDATEC-Industrial-Automation-and-Controls-User-FIG-59

Kanunay nga Gipangutana nga mga Pangutana

P: Mahimo ba nako i-install pag-usab ang operating system sa ED-PAC3020?

A: Reinstalling the operating system will invalidate the CODESYS license that comes pre-installed by default. It is advised not to attempt installing the OS on your own.

P: Unsa nga mga sumbanan sa programming ang gisuportahan sa ED-PAC3020?

A: The device supports IEC 61131-3 programming standards and industrial communication protocols like EtherCAT and Modbus TCP.