📘 Baseline manuals • Free online PDFs
Baseline logo

Baseline Manuals & User Guides

Baseline manufactures professional diagnostic and measurement instruments used in physical therapy, rehabilitation, and sports medicine, including dynamometers and goniometers.

Tip: include the full model number printed on your Baseline label for the best match.

About Baseline manuals on Manuals.plus

Baseline is a prominent brand of measurement and evaluation instruments manufactured by Fabrication Enterprises Inc. (FEI). Widely used by physical therapists, occupational therapists, and healthcare professionals, Baseline products are designed to accurately measure muscle strength, range of motion, and sensory perception.

The product lineup includes hydraulic hand and wrist dynamometers, pinch gauges, goniometers, inclinometers, and sensory evaluators like monofilament pens. Known for their durability and clinical accuracy, Baseline instruments often feature industry-accepted designs essential for tracking patient progress during rehabilitation. The brand provides a comprehensive range of tools suitable for both clinical settings and routine medical screenings.

Baseline manuals

Latest manuals from manuals+ curated for this brand.

BASELINE 12-0114 Wrist Evaluation Sets Instruction Manual

BASELINE 12-0114 Wrist Evaluation Sets Instruction Manual

December 3, 2025
Wrist Evaluation Sets Instruction Manual REF 12-0114, 12-0115 Intended Purpose The Baseline® wrist evaluation set is a medical/therapeutic device designed to measure wrist muscle strength (during flexion, extension, abduction, adduction,…
BASELINE 12-0502 Wrist Inclinometer Instruction Manual

BASELINE 12-0502 Wrist Inclinometer Instruction Manual

November 30, 2023
BASELINE 12-0502 Wrist Inclinometer Instruction Manual Pronation / Supination Inclinometer The handle is removable and Acu-Angle® “feet” attachments are available to use item as Acu-Angle® inclinometer. To remove handle, loosen…
BASELINE 12-1370 Multi Filament Pen Instruction Manual

BASELINE 12-1370 Multi Filament Pen Instruction Manual

November 21, 2023
BASELINE 12-1370 Multi Filament Pen About the Baseline® Multi-Filament Pen The Baseline® Multi-Filament Pen sensory evaluator is used to measure the cutaneous sensory perception threshold. The monofilament test provides a…
BASELINE 12-1099 Scoliosis Meter Instruction Manual

BASELINE 12-1099 Scoliosis Meter Instruction Manual

October 17, 2022
BASELINE 12-1099 Scoliosis Meter During routine spinal examinations, use the Baseline® Scoliosis Meter to measure the degree of rotation of a deformity of the back. This information can be used…
BASELINE 12-1057 Digital Inclinometer User Manual

BASELINE 12-1057 Digital Inclinometer User Manual

October 16, 2022
12-1057 Digital Inclinometer User Manual Digital Inclinometer EASY TO USE Range-of-motion can be read directly after the joint has been taken through its range. Place the inclinometer near the joint…
BASELINE 12-1110 Skinfold Caliper User Manual

BASELINE 12-1110 Skinfold Caliper User Manual

September 26, 2022
BASELINE 12-1110 Skinfold Caliper INTRODUCTION The Baseline Skinfold caliper is used to measure the thickness of “skin folds”. Measurements are taken at selected sites. The resultant skinfold thickness is then…
Baseline Plastic Angled Goniometer User Manual

Baseline Plastic Angled Goniometer User Manual

User Manual
User manual for the Baseline Plastic Angled Goniometer (Model 12-1195) from Fabrication Enterprises Inc. Details intended purpose, usage instructions, measurement tolerance, and disposal guidelines for this medical measuring instrument.
Baseline Deluxe Digital Scale Model 12-1190: Instructions for Use

Baseline Deluxe Digital Scale Model 12-1190: Instructions for Use

Instructions
Comprehensive instructions for the Baseline Deluxe Digital Scale (Model 12-1190), covering features, specifications, operation, personal parameter setting, measurement, recalling records, and troubleshooting. Learn how to monitor body fat, hydration, muscle,…
Baseline Body Level and Scoliosis Meter User Guide

Baseline Body Level and Scoliosis Meter User Guide

manual
This guide provides instructions and information on using the Baseline Body Level and Scoliosis Meter for measuring body alignment and detecting spinal curvatures. It includes details on how to perform…

Baseline manuals from online retailers

Baseline Lite Hydraulic Hand Dynamometer User Manual

Baseline Lite Hydraulic Hand Dynamometer User Manual

W54652 • August 21, 2025
Comprehensive user manual for the Baseline 12-0241 Lite Hydraulic Hand Dynamometer, covering setup, operation, maintenance, troubleshooting, and specifications for accurate grip strength measurement.

Baseline support FAQ

Common questions about manuals, registration, and support for this brand.

  • How do I reset the maximum reading on a Baseline hydraulic dynamometer?

    To reset the maximum reading pointer, rotate the small knurled knob on the dial indicator counter-clockwise until the red pointer rests against the black pointer at the zero marking.

  • What type of maintenance do Baseline measurement grips require?

    Grip surfaces should be cleaned with a mild disinfectant between patients. Do not submerge the unit in water or other liquids, as they are precision instruments.

  • Does the Baseline wrist dynamometer need calibration?

    The unit is sealed and calibrated at the factory. However, if the indicator needle is out of the zero-range, it can be reset by removing the clear cover and adjusting the pin near the 220Kg marking. If fluid leaks, the unit must be returned to the factory.

  • What is the warranty period for Baseline products?

    Many Baseline hydraulic instruments, such as the wrist dynamometer and pinch gauges, typically carry a 1-year or 2-year manufacturer's warranty covering parts and labor. Check your specific product manual for details.

  • How do I change the battery on the Baseline Electronic Pinch Gauge?

    Slide the battery cover down to remove it. Push the metal clip outward to release the battery. Insert a new 3V CR2032 battery with the positive (+) side facing out, then replace the cover.