Broan FG7T C,L Two Stage Variable Speed Condensing Upflow Horizontal Owner’s Manual
Broan FG7T C,L Two Stage Variable Speed Condensing Upflow Horizontal

FEATURES and BENEFITS

  • Energy efficient brushless CM) motor gives to 1 SEER point efficiency gain in cooling.
  • 100% fired and tested: All units and each component are tested on the manufacturing line
  • Best packaging in the industry: Unique comer post design assures product will arrive to the homeowner dent free
  • 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). 30 second post purge: Increases life of heat exchanger
  • Two Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels
  • Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
  • High Static Blowers: All models equipped with high static blowers.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life
  • 90 second fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE cod
  • LP convertible: Simple burmer orifice and regulator spring change for ease of convertibility
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated lightforflarne signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes • Incorporates integrated control board: With connections for electronic air cleaner and humidifier.
  • Two piece door design: Enhances fumace appearance and uses captured screws to prevent losing door screws
  • Blower Compartment: Sealed door to reduce airleakage and insulated for ultra quiet operation
  • Sealed Vestibule: Reduces burner and inducer sound levels

LOCATION OF FURNACE COMPONENTS

Upflow/Horizontal Gas Furnace Components AIR FLOW
FURNACE COMPONENTS

Downflow Gas Furnace Components
FURNACE COMPONENTS

DIMENSIONS

FG7TC 95.1+ High Efficiency Upflow/Horizontal Series

 

*TC Model #’s Dimension “A” Dimension “B” Dimension “C”
060D-VB 17/2 1578 16/8
080D-VC 21 193% 19%
100D-VC
120D-VD 24 1/2 227/8 23 18

NOTE: Dimensions shown in inches

FG7TL 95.1+ High Efficiency Downflow Series

*TC Model #’s Dimension “A” Dimension “B” Dimension “C”
060D-VB 17/2 1578 16/8
080D-VC 21 193% 19%
100D-VC
120D-VD 24 1/2 227/8 23 18

NOTE: Dimensions shown in inches

BLOWER PERFORMANCE – FG7TC/TL

Nominal Heating Airflows (CFM) and Temperature Rise (°F)

B Cabinet *TC/TL-060D-VBModels
Switch SettingsHEAT Input (BTU) 60000
 A/B    2  3  4  CFM Temp Rise (ºF)
1 0 0 0 1000 53
1 0 0 1 1100 48
1 0 1 0 1200 44
1 0 1 1 1300 41
1 1 0 0 1400 38
1 1 0 1 1500 35
1 1 1 0 1600 33
1 1 1 1 1700 31
C Cabinet *TC/TL-080D-VCModels *TC/TL-100D-VCModels
Switch SettingsHEAT Input (BTU) 80000 Input (BTU) 100000
 A/B    2  3  4  CFM Temp Rise (ºF)  CFM Temp Rise (ºF)
# 0 0 0 1000 70 1000 88
# 0 0 1 1115 63 1115 79
# 0 1 0 1230 57 1230 72
# 0 1 1 1345 52 1345 65
# 1 0 0 1460 48 1460 60
# 1 0 1 1575 45 1575 56
# 1 1 0 1690 42 1690 52
# 1 1 1 1805 39 1805 49

#Switch not used – can be 0 or 1

D Cabinet *TC/TL-120D-VDModels
Switch Settings HEAT Input (BTU) 120000
 A/B    2  3  4  CFM Temp Rise (ºF)
# 0 0 0 1500 70
# 0 0 1 1615 65
# 0 1 0 1730 61
# 0 1 1 1845 57
# 1 0 0 1960 54
# 1 0 1 2075 51
# 1 1 0 2190 48
# 1 1 1 2305 46

Notes:

  1. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  2. Temperature rises in the table are approximate. Actual temperature rises may vary.
  3. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.
  4. The blower operating range is .1″ to .8″ ESP in wc.

COOLING AIRFLOW

A Cabinet  Nominal A/C and HP Capacity
Switch Settings  CFM
HEAT COOL
A/B 5 6 7 8 LOW HIGH
0 0 0 0 0 360 525 1.5 TON
0 0 0 0 1 400 580
0 0 0 1 0 440 635 2 TON
0 0 0 1 1 475 690
0 0 1 0 0 515 745
0 0 1 0 1 550 800
0 0 1 1 0 590 855
0 0 1 1 1 630 910 2.5 TON
0 1 0 0 0 665 965
0 1 0 0 1 705 1020
0 1 0 1 0 740 1075 3 TON
0 1 0 1 1 780 1130
0 1 1 0 0 820 1185
0 1 1 0 1 855 1240
0 1 1 1 0 895 1295
0 1 1 1 1 930 1350
B Cabinet  Nominal A/C and HP Capacity
Switch Settings  CFM
HEAT COOL
A/B 5 6 7 8 LOW CFM
1 0 0 0 0 485 700 2 TON
1 0 0 0 1 525 760
1 0 0 1 0 565 820 2.5 TON
1 0 0 1 1 605 880
1 0 1 0 0 650 940
1 0 1 0 1 690 1000
1 0 1 1 0 730 1060 3 TON
1 0 1 1 1 775 1120
1 1 0 0 0 815 1180
1 1 0 0 1 855 1240 3.5 TON
1 1 0 1 0 895 1300
1 1 0 1 1 940 1360
1 1 1 0 0 980 1420
1 1 1 0 1 1020 1480
1 1 1 1 0 1065 1540
1 1 1 1 1 1105 1600
C Cabinet  Nominal A/C and HP Capacity
Switch Settings  CFM
HEAT COOL
A/B 5 6 7 8 LOW CFM
# 0 0 0 0 705 1025 2.5 TON
# 0 0 0 1 750 1090 3 TON
# 0 0 1 0 795 1155
# 0 0 1 1 840 1220
# 0 1 0 0 885 1285 3.5 TON
# 0 1 0 1 930 1350
# 0 1 1 0 975 1415 4 TON
# 0 1 1 1 1020 1480
# 1 0 0 0 1065 1545
# 1 0 0 1 1110 1610
# 1 0 1 0 1155 1675 5 TON
# 1 0 1 1 1200 1740
# 1 1 0 0 1245 1805
# 1 1 0 1 1290 1870
# 1 1 1 0 1335 1935
# 1 1 1 1 1380 2000
D Cabinet  Nominal A/C and HP Capacity
Switch Settings  CFM
HEAT COOL
A/B 5 6 7 8 LOW CFM
# 0 0 0 0 965 1400 3.5 TON
# 0 0 0 1 995 1440 4 TON
# 0 0 1 0 1020 1480
# 0 0 1 1 1050 1520
# 0 1 0 0 1075 1560
# 0 1 0 1 1105 1600
# 0 1 1 0 1130 1640
# 0 1 1 1 1160 1680
# 1 0 0 0 1185 1720 5 TON
# 1 0 0 1 1215 1760
# 1 0 1 0 1240 1800
# 1 0 1 1 1270 1840
# 1 1 0 0 1295 1880
# 1 1 0 1 1325 1920
# 1 1 1 0 1350 1960
# 1 1 1 1 1380 2000

VENTING

All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths

VENT TABLE

 

 FURNACE MODELS (BTU)

  FURNACE INSTALLATION SINGLE PIPE LENGTH (FT.)with 1 long radius elbow** DIRECT VENT,DUAL PIPE LENGTH (ft.) WITH1 long radius elbow on each pipe**
OUTLET OUTLET INLET/OUTLET INLET/OUTLET
2” Diameter 3” Diameter 2” Diameter 3” Diameter
  60,000 Upflow 90 90 90 90
Horizontal 50 90 50 90
Downflow 30 90 30 90
  80,000 Upflow 40 90 40 90
Horizontal 30 90 30 90
Downflow 30 90 30 90
  100,000 Upflow 30 90 30 90
Horizontal 30 90 30 90
Downflow 30 90 25 90
  120,000 Upflow N/A 90 N/A 90
Horizontal N/A 90 N/A 90
Downflow N/A 90 N/A 90

NOTES:

  1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2″ tee and 8ft for each 3″ tee.
  2. Two 45 degree elbows are equivalent to one 90 degree elbow.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

MODEL IDENTIFICATION CODE

MODEL IDENTIFICATION CODE

SPECIFICATIONS

FG7TC/TL MODELS NUMBERS:  -060D-VB  -080D-VC  -100D-VC  -120D-VD
Input – Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 120,000 / 78,000
Heating Capacity – Btuh 57,000 / 37,050 76,000 / 49,400 95,000 / 61,750 114,000 / 74,100
AFUE 95.1 95.1 95.1 95.1*
Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10
Motor H.P. – Speed – Type 1/2 – Variable 3/4 – Variable 3/4 – Variable 1 – Variable
Motor FLA 6.2 8.7 8.7 11.70
Rated Ext. SP – In. W.C. 0.5 0.5 0.5 0.5
Temperature Rise Range – ºF 30-60 35-65 35-65 40-70
Shipping Weights 125lbs 135lbs 145lbs 160lbs

“TL 120 is 94.8% AFUE

Note:

All models are 115V, 60 Hz. Gas Connections are 1/2″ NPT AFUE-Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2.000 it reduce 41% for each 1,000 ft. above sea level.

ACCESSORIES

FG7TC/TL KITS
Description SKU
2″ Concentric vent kit 904952
3″ Concentric vent kit 904953
“A” Cabinet downflow sub base kit 902974
“B”, “C”, “D” Cabinet downflow sub base kit 904911
2″ Side wall vent kit 904617
3″ Side wall vent kit 904347
U.S. LP Conversion kit (0 to 10,000 ft.) 904914
Canada LP Conversion kit (0 to 4,500 ft.) 904915
Bottom return filter 20 per box, “A” cabinet 903088
Bottom return filter 20 per box, “B” cabinet 904916
Bottom return filter 20 per box, “C” cabinet 904917
Bottom return filter 20 per box, “D” cabinet 904918
Side return filter kit 541036
Neutralizer kit 902377

GENERAL TERMS OF LIMITED WARRANTY

ANODYNE will furnish a replacement for any part of this product which fails in normal use and service in accordance with the terms of the warranty.

For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the ANODYNE warranty department for a copy.
Icon Icon

SALE 8000 Phoenix Parkway | O’Fallon, MO 63368-3827 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (03/2014) 218D-0314 (Replaces 218D-0212)

www.broanhvac.net

Bround bademark used under lounas Nortex Global HVAC LLC All Rights Rand

Company Logo

Documents / Resources

Broan FG7T C,L Two Stage Variable Speed Condensing Upflow Horizontal [pdf] Owner's Manual
FG7T C L Two Stage Variable Speed Condensing Upflow Horizontal, FG7T C L, Two Stage Variable Speed Condensing Upflow Horizontal, Variable Speed Condensing Upflow Horizontal, Condensing Upflow Horizontal, Upflow Horizontal

References

Leave a comment

Your email address will not be published. Required fields are marked *