Owner's Manual for Broan models including: FG7T C L Two Stage Variable Speed Condensing Upflow Horizontal, FG7T C L, Two Stage Variable Speed Condensing Upflow Horizontal, Variable Speed Condensing Upflow Horizontal, Condensing Upflow Horizontal, Upflow Horizontal
FG7T(C,L) - VS | Gas Furnace | Broan | Literature Library
File Info : application/pdf, 8 Pages, 590.73KB
DocumentDocumentTECHNICAL SPECIFICATIONS FG7T (C and L Series) , Smartlite® Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000 - 120,000 Btuh FEATURES and BENEFITS i SEER: 100% fired and tested: Best packaging in the industry: 30 second blower delay: 30 second post purge: Two Stage Inducer: Hot surface igniter: ® Color coded wire harness: Flexible category IV venting system: High Static Blowers: Low Boy Height: Tubular primary heat exchanger: 90 second fixed cooling cycle blower-off delay (TDR): LP convertible: Diagnostic lights for easy troubleshooting without counting flashes: Incorporates integrated control board: Two piece door design: Blower Compartment: Sealed Vestibule: LOCATION OF FURNACE COMPONENTS Flame Sensor Finish Flange Roll-Out Switch Burner Assembly Pressure Switches (Inducer) Main Air Limit Switch Inducer Limit Switch Inducer Assembly Blower Door Switch AIR FLOW Igniter Gas Valve Furnace Control Board Pressure Switches (Condensate) Transformer Motor Control Box Motor Choke (C & D cabinets only) 1 2 34 5678 Motor Control Board Blower Assembly Upflow/Horizontal Gas Furnace Components Blower Assembly (behind blower panel) Motor Choke (C & D cabinets only) Finish Flange Furnace Control Board Motor Control Board 1 2 34 5678 Blower Door Switch (behind blower panel) Transformer Pressure Switches Vent Limit Switch AIR FLOW Inducer Assembly Gas Valve Igniter Main Air Limit Switch Flame Sensor Burner Assembly Roll-Out Switch Gas Manifold Downflow Gas Furnace Components 2 DIMENSIONS *TC Dimension Dimension Dimension Model #'s "A" "B" "C" ½ ½ TOP VIEW B FLANGES 19 23 1/2 BOTTOM VIEW C Front Brace Bottom Panel 3 1/4 Combustion Air 2 3/4 22 1/2 25 3/8 22 1/2 Vent pipe (Ø 3") T-stat (Ø 7/8) Electric (Ø 7/8) Gas (Ø 1 5/8) A T-stat (Ø 7/8) Vent pipe (Ø 3") Electric (Ø 7/8) 22 1/2 Gas (Ø 1 5/8) 24 7/8 34 1/2 17 1/4 17 7/8 4 Knockouts (both sides) 1 Cond. (Ø 1 1/16) 28 LEFT SIDE Condensate (Ø 1 1/16) FRONT VIEW 23 RIGHT SIDE FG7TC 95.1+ High Efficiency Upflow/Horizontal Series 15 1 1/4 *TL Dimension Dimension Dimension Model #'s "A" "B" "C" ½ ½ TOP VIEW B FLANGES 19 Flue 3 Combustion Air 7 1/2 28 25 1/4 22 1/4 25 1/2 Electric (Ø 7/8) Gas (Ø 1 5/8) T-stat (Ø 7/8) A Electric (Ø 7/8) Gas (Ø 1 5/8) 34 1/2 10 1/4 17 1/4 22 1/2 Vent pipe (Ø 3") Cond. (Ø 1 1/16) LEFT SIDE FRONT VIEW FG7TL 95.1+ High Efficiency Downflow Series 18 1/2 BOTTOM VIEW C Front Brace 22 1/4 25 Vent pipe (Ø 3") 22 1/2 25 3/8 Cond. (Ø 1 1/16) RIGHT SIDE 22 1/2 17 1/4 17 7/16 29 1/2 3 BLOWER PERFORMANCE - FG7TC/TL Nominal Heating Airflows (CFM) and Temperature Rise (°F) B Cabinet Switch Settings HEAT *TC/TL-060D-VB Models Input (BTU) 60000 D Cabinet Switch Settings HEAT # # # # # # # # *TC/TL-120D-VD Models Input (BTU) 120000 C Cabinet Switch Settings HEAT # # # # # # # # *TC/TL-080D-VC *TC/TL-100D-VC Models Models Input (BTU) 80000 Input (BTU) 100000 4 COOLING AIRFLOW A Cabinet Switch Settings HEAT COOL CFM A/B 5 6 7 8 LOW HIGH 0 0 0 0 0 360 525 0 0 0 0 1 400 580 0 0 0 1 0 440 635 0 0 0 1 1 475 690 0 0 1 0 0 515 745 0 0 1 0 1 550 800 0 0 1 1 0 590 855 0 0 1 1 1 630 910 0 1 0 0 0 665 965 0 1 0 0 1 705 1020 0 1 0 1 0 740 1075 0 1 0 1 1 780 1130 0 1 1 0 0 820 1185 0 1 1 0 1 855 1240 0 1 1 1 0 895 1295 0 1 1 1 1 930 1350 3 TON 2.5 TON Nominal A/C and HP Capacity 2 TON 1.5 TON C Cabinet Switch Settings HEAT COOL CFM A/B 5 6 7 8 LOW CFM # 0 0 0 0 705 1025 # 0 0 0 1 750 1090 # 0 0 1 0 795 1155 # 0 0 1 1 840 1220 # 0 1 0 0 885 1285 # 0 1 0 1 930 1350 # 0 1 1 0 975 1415 # 0 1 1 1 1020 1480 # 1 0 0 0 1065 1545 # 1 0 0 1 1110 1610 # 1 0 1 0 1155 1675 # 1 0 1 1 1200 1740 # 1 1 0 0 1245 1805 # 1 1 0 1 1290 1870 # 1 1 1 0 1335 1935 # 1 1 1 1 1380 2000 # Switch not used - can be 0 or 1 5 TON 4 TON Nominal A/C and HP Capacity 3.5 TON 3 TON 2.5 TON B Cabinet Switch Settings HEAT COOL CFM A/B 5 6 7 8 LOW CFM 1 0 0 0 0 485 700 1 0 0 0 1 525 760 1 0 0 1 0 565 820 1 0 0 1 1 605 880 1 0 1 0 0 650 940 1 0 1 0 1 690 1000 1 0 1 1 0 730 1060 1 0 1 1 1 775 1120 1 1 0 0 0 815 1180 1 1 0 0 1 855 1240 1 1 0 1 0 895 1300 1 1 0 1 1 940 1360 1 1 1 0 0 980 1420 1 1 1 0 1 1020 1480 1 1 1 1 0 1065 1540 1 1 1 1 1 1105 1600 3.5 TON 3 TON 2.5 TON 2 TON Nominal A/C and HP Capacity D Cabinet Switch Settings HEAT COOL CFM A/B 5 6 7 8 LOW CFM # 0 0 0 0 965 1400 # 0 0 0 1 995 1440 # 0 0 1 0 1020 1480 # 0 0 1 1 1050 1520 # 0 1 0 0 1075 1560 # 0 1 0 1 1105 1600 # 0 1 1 0 1130 1640 # 0 1 1 1 1160 1680 # 1 0 0 0 1185 1720 # 1 0 0 1 1215 1760 # 1 0 1 0 1240 1800 # 1 0 1 1 1270 1840 # 1 1 0 0 1295 1880 # 1 1 0 1 1325 1920 # 1 1 1 0 1350 1960 # 1 1 1 1 1380 2000 5 TON 4 TON 3.5 TON Nominal A/C and HP Capacity 5 VENTING FURNACE MODELS (BTU) FURNACE INSTALLATION VENT TABLE SINGLE PIPE LENGTH (FT.) with 1 long radius elbow** OUTLET 2" Diameter OUTLET 3" Diameter DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe** INLET/OUTLET INLET/OUTLET 2" Diameter 3" Diameter *NOTES: 6 MODEL IDENTIFICATION CODE FG 7 T C 090 C V B Cabinet Width Cooling Airflow Input Heating Capacity SPECIFICATIONS FG7TC/TL MODELS NUMBERS: AFUE -060D-VB -080D-VC -100D-VC -120D-VD 7 ACCESSORIES Description FG7TC/TL KITS SKU GENERAL TERMS OF LIMITED WARRANTY 218D-0314 (Replaces 218D-0212) www.broanhvac.net Broan® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved. Powered by TCPDF (www.tcpdf.org)