XH Series Data Logger

  • Set Logging of statistical data of temperature & humidity
  • Wireless configuration, monitoring; set parameter & download report via Wi-Fi
  • M.K.T. Mean Kinetic Temperature calculation
  • USB/ Battery power supply

BrainChild-XH12-Data-Logger- (3)

XHLogger Quick Start

Copyright © 2024 BrainChild Electronic Co., Ltd. All rights reserved.

Package

  • Data Logger x 1
  • XH12 Battery Installed (3.7V/ 1500mA Li-ion)
  • (Rechargeable Li Battery)
  • Mounting Plate/ Fixed Sticker x 1
  • Screws/ Anchors x 2
  • Quick User Guide x 1
  • External Sensor Probe x 1Tech Support: service@brainchild.com.tw XH12 QSG ENv1.0, 2024-05-23

Mounting Plate

Back/ Front Plate

BrainChild-XH12-Data-Logger- (5)Bracket + XHLogger Place the XHLogger into the mounting bracket

BrainChild-XH12-Data-Logger- (6)LED

  • Flashing Red/ Green LED, indicating devices startup successfully
  • Flashing Green LED, indicating working in recording monitoring mode
  • Flashing Red LED, indicating errors occurred, alarms triggered
  • Red LED blinking 3 times & off continuously, when the connection is interrupted BrainChild-XH12-Data-Logger- (7)

LCD Display

  1. BrainChild-XH12-Data-Logger- (8)The symbol BrainChild-XH12-Data-Logger- (9)indicates unit recording. Recording will start only when the timer matching settings. Flashing indicates BrainChild-XH12-Data-Logger- (9)delayed reocrding, pending for scheduled tasks.
    The symbolBrainChild-XH12-Data-Logger- (9) will disappear after logging completed.
  2. Battery capacity displayed in proportion
  3. Remaining memory capacity displayed in proportion
  4. The wrench indicatesBrainChild-XH12-Data-Logger- (10) errors occurred, disappears when confirms no error occurred.
  5. Real-time temperature or humidity info.
  6. ALM bar: When temperature/humidity reaching the alarm condition,BrainChild-XH12-Data-Logger- (11)(Low Limit)
  7. Temperature Unit °C/ °F
  8. ALM: When temperature/humidity value reaching the alarm trigging condition
  9. Max. temperature/humidity Value
  10. Min. temperature/humidity Value
  11. MKT: Mean Kinetic Temperature Caculation
  12. File: Total number of files
  13. HL: High Limit
  14. MH: month/ hour
  15. Log: Log interval
  16. %H: Relative Humidity %
  17. LL: Low Limit
  18. DLY: Delay Time
  19. DM: date/ minute

Please refer to User Manual, Configuration & Data Analysis, for more information

3-Key Operation

 

BrainChild-XH12-Data-Logger- (12)

Operation Mode

BrainChild-XH12-Data-Logger- (13)

Data Configuration/ Analysis

Download DLV, the Data Logger Viewer software, from the manufacturer’s website. The PC Software can be used for configuration of the data logger, viewing and analysing of historical data.
NOTE: *Recording has been locked by default factory settings, please reset time zone firstly & time interval.

Wi-Fi PairingBrainChild-XH12-Data-Logger- (14)

Quick and easy wireless pairing

  • Take one XH12 which is new to the system BrainChild-XH12-Data-Logger- (15)(If this XH device used before, already paired wireless before, press the third button, STOP BrainChild-XH12-Data-Logger- (16)key, more than 3 secs for 5 times, thus clear the previous Wi-Fi setting)
  • Open the DLV software on your PC via micro USB port. Go to <Sensors> on the top menu.
  • Press and hold sync the 2&3 keys,BrainChild-XH12-Data-Logger- (17) for 3 secs. rEG registration steps will appear.
  • Wi-Fi setting screen appeared on DLV, follow the sequence steps to complete wireless pairing.
  • Press <Finish> after pairing successfully. Go to <Sensors> list-page, the connected Wi-Fi already discovered on the page.

Sensor > New > SSID/PWD > Next > rEG > Finish

 

BrainChild-XH12-Data-Logger- (19) BrainChild-XH12-Data-Logger- (20)

DLV Quick Activation

  1. Step 1: Connect the XHLogger to PC, micro-USB plug of the USB cable into the PC USB port.
    *Use only USB data file transfer cables to collect data for analysis
  2. Step 2: The Sensor list will renew newly discoveried devices, click <View> of new items
  3. Step 3: Go to <Parameter> set your local time zone BrainChild-XH12-Data-Logger- (21)
  4. Step 4: Set <Log Interval>, the number must not be zero
  5. Step 5: Press <Save> after all settings applied

 

BrainChild-XH12-Data-Logger- (22)

Error Code

BrainChild-XH12-Data-Logger- (1)BrainChild-XH12-Data-Logger- (10)An error symbol will appear when any error occurred

If you have any other tech problems, please contact us and provide the serial number on the sticker from the back of the device.

Battery Charge

* The XH12 uses a rechargeable battery; when receiving the brand new product, before usage for the first time, please charge the new device to full level via USB port. Use one microUSB-USB cable, connecting USB port to power supply DC5V/1A. When the device completely no power, less than 20%, the totally charging time to fully charged takes around 4 hr to finish with connecting to DC5V/1A charging adapter. For normal usage, recharge the device every 2 to 3 months.

 

BrainChild-XH12-Data-Logger- (2)

Tech Support:
service@brainchild.com.tw
XH12 QSG ENv1.0, 2024-05-23

XH12 

Frequently Asked Tech Support Questions

After successfully paring DLV with XH12, do I need to keep DLV software open to stay connection

For normal usage, the XH12 will keep connection with DLV, also sending data back to DLV continuously. When the XH12 cannot find DLV, it will try to search DLV and the LED screen will display Er04, which will make battery draining fast. Even power saving mechanisms exist, it is recommended to keep the connection between DLV and XH12 all the time

During pairing processing, cannot find any XH12 device on the list?

Press the STOP button 5 times, and wait until “rSt” displayed on LED to clear paring setting on this device. Manually operate the pairing procedure again. Enter and make sure paring networking SSID and password correct. Before pairing again, check Wi-Fi and networking environment, whether the signal too weak on the location. Also avoid turning phone hotspot to replacing Wi-Fi, which cause networking connection unstable. Please note that it is required to run program under windows 10 OS or above.

Will the connection between DLV and XH12 failed after when the DHCP assigns a new IP address

Under normal network circumstances, DLV and XH12 use the same domain for connection. When IP address on the computer changed, DLV will still search and update the link automatically.

When the error code, Er05, is shown on XH12 LED

Er05 occurs when XH12 cannot connect to the paired Wi-Fi, so please check the network device firstly and then restart the DLV software and confirm that IP domain of DLV is the same as setting before.

How to reconnect the device with DLV software again

The device has been paired successfully before, yet if the device unexpected disconnection problems occur, the user can try to pair again to establish the connection between XH12 and DLV. Press the STOP button 5 times, and wait until “rSt” displayed on LED to clear paring setting on this device. Manually operate the pairing procedure again.

The DLV is activated and finished pairing but my XH12 cannot work properly

The first step to activate DLV is to click on the device name; go to Parameter firstly to reset Log Interval Time Zone. Set Log Interval not zero H M S and set current Time Zone. Save and Exit

How to change the DLV language interface

To change the DLV language, click on the device name and go to Settings on the top menu. On the General tab, change Language field and Exit the program. Launch the DLV again, the new language interface will start.

Documents / Resources

BrainChild XH12 Data Logger [pdf] User Guide
XH12, XH12 Data Logger, Data Logger, Logger

References

NEXSENS X2 X2 Data Logger User Guide

X2 X2 Data Logger User Guide X2 X2 Data Logger IMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new…

  • METER ZL6 Data logger featured
    METER ZL6 Data logger User Guide

    METER ZL6 Data logger Preparation Inspect and verify ZL6 components are intact. Installation will require a mounting post.…

    <
    /li>
  • DICKSON DWE2 Data Logger
    DICKSON DWE2 Data Logger User Guide

    DICKSON DWE2 Data Logger Important Information This Quick-start Guide presents an overview of the Dickson DWE data logger,…

  • <
    /div>

    Leave a comment

    Your email address will not be published. Required fields are marked *