User Guide for BrainChild models including: XH12, XH12 Data Logger, Data Logger, Logger

XH12-QSG-QS0XH120A EN v1.0.01

XHLogger Quick Start XH Series Data Logger

PDF preview unavailable. Download the PDF instead.

XH12-QSG-QS0XH120A EN v1.0.01
'PS%BUB-PHHFS .PEFM9) 7FS249)"
9)4FSJFT%BUB-PHHFS

w4FU-PHHJOHPGTUBUJTUJDBMEBUBPG
UFNQFSBUVSFIVNJEJUZ
w8JSFMFTTDPOpHVSBUJPO
NPOJUPSJOHTFUQBSBNFUFS EPXOMPBESFQPSUWJB8J'J
w.,5.FBO,JOFUJD5FNQFSBUVSF
DBMDVMBUJPO
w64##BUUFSZQPXFSTVQQMZ

5FDI4VQQPSU TFSWJDF!CSBJODIJMEDPNUX 9)24(&/W

9)-PHHFS2VJDL4UBSU
$PQZSJHIU#SBJO$IJME&MFDUSPOJD$P
-UE"MMSJHIUTSFTFSWFE

1BDLBHF
- Data Logger x 1 XH12 Battery Installed (3.7V/ 1500mA Li-ion) (Rechargeable Li Battery)
.JDSP64#QPSU 4UBSU
4DSPMM 4UPQ

- Mounting Plate/ Fixed Sticker x 1 - Screws/ Anchors x 2 - Quick User Guide x 1 - External Sensor Probe x 1
3FE-&% (SFFO-&%
&YUFSOBM4FOTPS .PEVMF

&YUFSOBM 4FOTPSQPSU

.PVOUJOH1MBUF
Back/ Front Plate
Fixing Magnet
Attach/ Fix the plate to any metal area using the magnetic base

4FOTPS$BCMF
Hanging Hole
Hang it on a wall mounting screw

Adhesive Tape
Remove adhesive sticker on the back of plate. Attach this side to wall

Mounting Screw Hole
Fix it by fasten the mounting screws

Bracket + XHLogger Place the XHLogger into the mounting bracket

-&%
w Flashing Red/ Green LED, indicating devices startup successfully
w Flashing Green LED, indicating working in recording monitoring mode
w Flashing Red LED, indicating errors occurred, alarms triggered w Red LED blinking 3 times & off continuously, when the connection is interrupted

-$%%JTQMBZ





 

 

   



    

 The symbol indicates unit recording. Recording will

start only when the timer matching settings. Flashing

indicates delayed reocrding, pending for scheduled tasks.

The symbol will disappear after logging completed.

 Battery capacity displayed in proportion

 Remaining memory capacity displayed in proportion

 The wrench

indicates errors occurred, disappears

when confirms no error occurred.

 Real-time temperature or humidity info.

 ALM bar: When temperature/humidity reaching the alarm

condition, HL (High Limit) or LL (Low Limit)

 Temperature Unit °C/ °F

 ALM: When temperature/humidity value reaching the alarm

trigging condition

 Max. temperature/humidity Value

 Min. temperature/humidity Value

.,5Mean Kinetic Temperature Caculation

File: Total number of files HL: High Limit MH: month/ hour Log: Log interval

%H: Relative Humidity % LL: Low Limit DLY: Delay Time DM: date/ minute

Please refer to User Manual, Configuration & Data Analysis, for more information.

,FZ0QFSBUJPO
Action START - Short press START - Long press more than 3 secs SCROLL - Short press
STOP - Long press more than 3 secs
SCROLL +STOP - Long press STOP - Press & Hold for 5 times

Description Reconnection Start recording Toggle screen views Stop recording after logging; Sleeping mode before logging Registration/ Pairing Reset

0QFSBUJPO.PEF

Start Recording Immediate (PC)

Description Immediate recording after unplugging the USB at USB mode when setting the XH through DLV

Long Press START key for more than 3 secs when setting

Button (XH12)

the XH through DLV whether to connect the USB or not The button mode also working with <Start Delay>, long press

START key for more than 3 secs. When reaching the start delay

time, it will automatically start recording

Specific Time (PC)

Start recording when reaching the specific time, when setting the XH through DLV whether to connect the USB or not

Stop Recording None
Button

Description Stop by DLV software only (via USB interface) Long press STOP key for more than 3 secs at logging mode, or stop by DLV software

Specific Time

When reaching the stop time, it will automatically stop recording, or stop by DLV software

%BUB$POpHVSBUJPO"OBMZTJT
Download DLV, the Data Logger Viewer software, from the manufacturer's website. The PC Software can be used for configuration of the data logger, viewing and analysing of historical data.
NOTE:Recording has been locked by default factory settings, please reset time zone firstly & time interval.

· 8J'J1BJSJOH
Sensor > New

%-78J'J1BJSJOH7JEFP

Quick and easy wireless pairing * Take one XH12 which is new to the system

(If this XH device used before, already paired wireless before, press the third button,

STOP key, more than 3 secs for 5 times, thus clear the previous Wi-Fi setting) * Open the DLV software on your PC via micro USB port. Go to <Sensors> on the top menu.

* Press and hold sync the 2&3 keys, Scroll+ Stop, for 3 secs. rEG registration steps will

appear.

* Wi-Fi setting screen appeared on DLV, follow the sequence steps to complete wireless pairing.

* Press <Finish> after pairing successfully. Go to <Sensors> list-page, the connected Wi-Fi already discovered on the page.

Sensor > New > SSID/PWD > Next > rEG > Finish 

Input ID/ Password

rEG

rEG step 4DSPMM

When match none

4UPQ

shown none listed

Finish pairing Press <Finish> to Exit

Sensor List
w%-72VJDL"DUJWBUJPO
Step 1: Connect the XHLogger to PC, micro-USB plug of the USB cable into the PC USB port. Use only USB data file transfer cables to collect data for analysis
Step 2: The Sensor list will renew newly discoveried devices, click <View> of new items
Step 3: Go to <Parameter> set your local time zone

Sensor > View
Step 4: Set <Log Interval>, the number must not be zero Step 5: Press <Save> after all settings applied

Parameter > Time Zone  Parameter > Log Interval 

Connect the XHLogger to your PC via USB transfer cable
Install Data logger viewer to your PC Double click on DLV logo Go to Parameter > Time Zone > Save Set correct time zone/ log interval Save the setting to initialize recording

&SSPS$PEF
Code Reason Er01 Wi-Fi module abnormal disconnection, failed to start, please restart or reset Er02 DLV registration failure, please registration and pairing again Er03 Login failed, please note whether ID/Password are correct, Wi-Fi signal as stable Er04 Connection with DLV failed, please check if Wi-Fi disconnected or DLV turned off. Er05 Wireless AP failed to connect, please check if the router is working properly. Er06 Sensor failure, please contact local dealers or the original manufacturer Er07 Firstly check whether the external sensor connected correctly firmly Er08 Device time stamp not available, device timer abnormal
Start recording without setting parameters, logging interval lerror, setting Er09
configuration error. Please reset. Go to Parameter > Data logging
The total files exceeds 100 and the memory is full. Please clear all file data

An error symbol will appear when any error occurred

9)'"2
 'SFRVFOUMZ"TLFE5FDI4VQQPSU2VFTUJPOT
 After successfully paring DLV with XH12, do I need to keep DLV software opening to stay connection? For normal usage, the XH12 will keep connection with DLV, also sending data back to DLV continuously. When the XH12 cannot find DLV, it will try to search DLV and the LED screen will display Er04, which will make battery draining fast. Even power saving mechanisms exist, it is recommended to keep the connection between DLV and XH12 all the time.

 During pairing processing, cannot find any XH12 device on the list? Press the STOP button 5 times, and wait until "rSt" displayed on LED to clear paring setting on this device. Manually operate the pairing procedure again. Enter and make sure paring networking SSID and password correct. Before pairing again, check Wi-Fi and networking environment, whether the signal too weak on the location. Also avoid turning phone hotspot to replacing Wi-Fi, which cause networking connection unstable. Please note that it is required to run program under windows 10 OS or above.

 Will the connection between DLV and XH12 failed after when the DHCP assigns a new IP address? Under normal network circumstances, DLV and XH12 use the same domain for connection. When IP address on the computer changed, DLV will still search and update the link automatically.

 When the error code, Er05, is shown on XH12 LED? Er05 occurs when XH12 cannot connect to the paired Wi-Fi, so please check the network device firstly and then restart the DLV software and confirm that IP domain of DLV is the same as setting before.

 How to reconnect the device with DLV software again? The device has been paired successfully before, yet if the device unexpected disconnection problems occur, the user can try to pair again to establish the connection between XH12 and DLV. Press the STOP button 5 times, and wait until "rSt" displayed on LED to clear paring setting on this device. Manually operate the pairing procedure again.

 The DLV is activated and finished pairing but my XH12 cannot work properly? The first step to activate DLV is to click on the device name; go to <Parameter> firstly to reset <Log Interval>, <Time Zone>. Set Log Interval not zero (H/M/S) and set current Time Zone. Save and Exit.

 How to change the DLV language interface? To change the DLV language, click on the device name and go to <Setting> on the top menu. On the <General > tab, change <Language> field and Exit the program. Launch the DLV again, the new language interface will start.

*** If you have any other tech problems, please contact us and provide the serial number on the sticker from the back of the device.

#BUUFSZ$IBSHF

* The XH12 uses a rechargeable battery; when receiving the brand new product, before usage for the first time, please charge the new device to full level via USB port. Use one microUSB-USB cable, connecting USB port to power supply DC5V/1A. When the device completely no power, less than 20%, the totally charging time to fully charged takes around 4 hr to finish with connecting to DC5V/1A charging adapter. For normal usage, recharge the device every 2 to 3 months.

Battery Level with 0-4 4 scales: Power 100%

USB-Powered USB-Charge: DC 5V/1A microUSB-USB

3 scales: Power 80%

2 scales: Power 60%

1 scale: Power 40%

0 scale: Power < 40%

Frame Blinking: Power < 20%

