The following tables detail the addresses, content, access types, definitions, and units for various system parameters.
Table 1: System Parameters (Addresses 49-58)
| Address | Content | Access type (W/R) | Definition | Type | Unit |
|---|---|---|---|---|---|
| 49 | INV module temp | R | Signed word | 0.1°C | |
| 50 | Suction temp | R | Signed word | 0.1°C | |
| 51 | Discharge temp | R | Signed word | 0.1°C | |
| 52 | Exchanger temp | R | Signed word | 0.1°C | |
| 53 | Outdoor temp | R | Signed word | 0.1°C | |
| 54 | Comp pressure | R | Signed word | 1kpa | |
| 55 | MV1_1 | R | 0:OFF, 1:ON | Signed word | |
| 56 | MV1_2 | R | 0:OFF, 1:ON | Signed word | |
| 57 | MV2 | R | 0:OFF, 1:ON | Signed word | |
| 58 | pump-I | R | 0:OFF, 1:ON | Signed word |
Table 2: System Parameters (Addresses 500+100*(n-1)+9 to 500+100*(n-1)+18)
| Address | Content | Access type (W/R) | Definition | Type | Unit |
|---|---|---|---|---|---|
| 500+100*(n-1)+9 | INV module temp | R | Signed word | 0.1A | |
| 500+100*(n-1)+10 | Suction temp | R | Signed word | 0.1°C | |
| 500+100*(n-1)+11 | Discharge temp | R | Signed word | 0.1°C | |
| 500+100*(n-1)+12 | Exchanger temp | R | Signed word | 0.1°C | |
| 500+100*(n-1)+13 | Outdoor temp | R | Signed word | 0.1°C | |
| 500+100*(n-1)+14 | Comp pressure | R | Signed word | 1kpa | |
| 500+100*(n-1)+15 | MV1_1 | R | 0:OFF, 1:ON | Signed word | |
| 500+100*(n-1)+16 | MV1_2 | R | 0:OFF, 1:ON | Signed word | |
| 500+100*(n-1)+17 | MV2 | R | 0:OFF, 1:ON | Signed word | |
| 500+100*(n-1)+18 | pump-I | R | 0:OFF, 1:ON | Signed word |
Usage Instructions
5.4.2 Fast DHW setting
This section describes how to configure the Fast Domestic Hot Water (DHW) settings, including disinfection and pump operation.
Setting Disinfect Time
- Navigate to the ‘DHW’ page.
- Select ‘Disinfect’.
- Select ‘Start at’ and press the
[|||]button to begin time setting. - Use the
[|||]or[|||]buttons to select the hour/minute. - Press the
[|||]or[|||]buttons to set the desired time (e.g., 23:00). - Select ‘Week’ and press the
[|||]button to choose the days for disinfection (Sun, Mon, Tue, Wed, Thu, Fri, Sat).
Enabling/Disabling Fast DHW
- On the ‘DHW’ page, select ‘Fast DHW’.
- Press the
[|||]or[|||]buttons to toggle ‘On’ or ‘Off’.
DHW Pump Settings
This allows you to configure up to four different start times for the DHW pump.
- On the ‘DHW’ page, select ‘DHW pump’.
- Press the
[|||]button to enter the DHW pump settings page. - You will see options for ’01 Start at’, ’02 Start at’, ’03 Start at’, and ’04 Start at’, each initially set to ’00:00′.
- For each ‘Start at’ option, follow the time setting procedure described in ‘Setting Disinfect Time’ to set the desired pump activation times.
Troubleshooting
No specific troubleshooting information is provided in the given text. Please refer to the full manual for detailed troubleshooting guides or contact customer support if issues arise.
Frequently Asked Questions
How do I set the time for DHW disinfection?
Navigate to the DHW page, select ‘Disinfect’, then ‘Start at’. Use the arrow buttons to set the hour and minute, and then select the days of the week.
Can I turn off the Fast DHW feature?
Yes, on the DHW page, select ‘Fast DHW’ and use the arrow buttons to set it to ‘Off’.
How many different start times can I set for the DHW pump?
You can set up to four different start times for the DHW pump (01 Start at, 02 Start at, 03 Start at, 04 Start at).
What does ‘R’ mean in the ‘Access type’ column of the specifications table?
‘R’ indicates that the parameter is Read-only, meaning its value can be viewed but not modified directly through this interface.
What do ‘0:OFF, 1:ON’ definitions mean?
These definitions indicate that the corresponding parameter (e.g., MV1_1, pump-I) is a binary state, where ‘0’ represents an ‘OFF’ state and ‘1’ represents an ‘ON’ state.
State
Disinfect
..
Start at
23:00
Sun Mon Tue Wed Thu Fri Sat
5.4.2 Fast DHW setting
DHW
Disinfect Fast DHW
…
DHWpump
Select Start at and press the [Il l to start
the time setting. Press the [lll or [111 to select hour/minute, and press the [lll or [111 to set the clock. Select Weekand press the [lll whether to select.
On the DHW page, select Fast DHW and Press the [lll or [111 to set On/Off.
DHW pump
01 Start at 02 Start at 03 Start at 04 Start at
00:00 00:00 00:00 00:00
On the DHW page, select DHW pump and press the [lll to en ter the DHW pump page.
28
Address Content
Access type(W/R)
49
INV module temp
R
Definition I
50
Suction temp
R
I
51
Discharge temp
R
I
52
Exchanger temp
R
I
53
Outdoor temp
R
I
54
Camp pressure
R
I
55
MV1_1
R
0:OFF, 1:ON
56
MV1 2
R
0:OFF, 1:ON
57
MV2
R
0:OFF, 1:ON
58
pump-I
R
0:OFF, 1:ON
42
Type
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Unit
o.re
0.1C
o.re
0.1C
o.re
1kpa I I I I
Address
500+100* (n-1)+9
500+100* (n-1)+10
500+100* (n-1)+11
500+100* (n-1)+12
500+100* (n-1)+13
500+100* (n-1)+14
500+100* (n-1)+15
500+100* (n-1)+16
500+100* (n-1)+17
500+100* (n-1)+18
Content
Access type(W/R)
INV module temp
R
Suction temp
R
Discharge temp
R
Exchanger temp
R
Outdoor temp
R
eomp pressure
R
MV1_1
R
MV1_2
R
MV2
R
pump-I
R
Definition I I I I I I
0:OFF, 1:ON 0:OFF, 1:ON 0:OFF, 1:ON 0:OFF, 1:ON
69
Type
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Signed word
Unit 0.1A 0.1 e o.re 0.1 e o.re 1kpa
I I I I
Documents / Resources
![]() | Xbox 360 Wired Controller |
References
- o.reo.re
- User Manualmanual.tools