Thank you for choosing the CO-Z 1.1 Gallon Water Distiller. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new water distiller. Please read these instructions carefully before use and retain them for future reference.
Important Safety Instructions
To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions when using electrical appliances. This appliance is designed for household and light commercial use. Do not use it for purposes other than its intended use.
- Ensure the power supply matches the voltage specified on the appliance.
- Do not immerse the distiller unit in water or other liquids.
- Keep the appliance out of reach of children.
- Always unplug the distiller from the power outlet before cleaning or when not in use.
- The distiller features an automatic shut-off function at approximately 330°F (165°C) to prevent overheating.
- The product is equipped with a UL Listed Plug and TUV Certified Wiring for enhanced safety.

Package Contents
Verify that all components are present in the package:
- Water Distiller Unit
- Water Collection Pot
- Carbon Filter Pack
- Citric Acid Cleaning Powder
- Power Cord
- User Manual
Product Overview
The CO-Z 1.1 Gallon Water Distiller is designed to provide purified water by effectively removing harmful chemicals, VOCs, and other solid contaminants from tap water. Its compact design and advanced features make it suitable for various applications.


Setup
Follow these steps to set up your water distiller for first-time use:
- Unpack: Carefully remove all components from the packaging.
- Clean: Before first use, clean the interior of the distiller and the collection pot with warm water and mild soap. Rinse thoroughly.
- Assemble: Place the distiller unit on a stable, flat, heat-resistant surface. Ensure adequate ventilation around the unit.
- Install Carbon Filter: Open the lid of the distiller. Insert one carbon filter pack into the designated slot in the spout of the distiller.
- Position Collection Pot: Place the water collection pot directly under the distiller's spout.
Operating Instructions
Operating your CO-Z water distiller is straightforward:
- Fill Water: Open the distiller lid and fill the stainless steel boiling chamber with tap water up to the MAX fill line. Do not overfill.
- Close Lid: Securely close the distiller lid.
- Connect Power: Plug the power cord into a grounded electrical outlet.
- Start Distillation: Press the power button on the control panel to begin the distillation process. The distiller will automatically heat the water to boiling, and steam will rise, condense, and drip into the collection pot.
- Timer & Reservation Function: Use the '+' and '-' buttons to set a precise operating time (0-99 hours) or to schedule a reservation for distillation to start at a later time. This feature helps optimize water production and save on energy costs by running during off-peak hours. Press 'SET' to confirm your selection.
- Automatic Shut-off: The distiller will automatically turn off once the water in the boiling chamber has evaporated or if the internal temperature reaches approximately 330°F (165°C).
- Collect Distilled Water: Once the cycle is complete and the unit has cooled, carefully remove the collection pot to access your purified water.



Maintenance and Cleaning
Regular cleaning is essential to maintain the performance and longevity of your distiller. Mineral deposits will accumulate in the boiling chamber over time.
- Daily Cleaning: After each use, unplug the unit and allow it to cool completely. Discard any remaining water in the boiling chamber. Rinse the boiling chamber and collection pot with clean water.
- Deep Cleaning (Mineral Deposits): When mineral deposits become visible, use the included citric acid cleaning powder.
- Fill the boiling chamber with approximately 1 liter of water.
- Add 1-2 tablespoons of citric acid cleaning powder.
- Close the lid and run a short distillation cycle (e.g., 30 minutes) or let it soak for several hours.
- After soaking, scrub the interior with a non-abrasive brush or cloth to remove loosened deposits.
- Rinse the boiling chamber thoroughly multiple times to ensure all cleaning solution is removed.
- Carbon Filter Replacement: Replace the carbon filter pack every 2-3 months, or as needed, to ensure optimal water quality.
Troubleshooting
If you encounter issues with your distiller, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Distiller does not turn on | No power supply; Power cord not properly connected | Check power outlet and ensure power cord is securely plugged in. |
| No distilled water produced | Insufficient water in boiling chamber; Unit not heating | Ensure water level is above the minimum. Contact customer support if unit is not heating. |
| Slow distillation process | Heavy mineral buildup; Low ambient temperature | Perform a deep clean to remove mineral deposits. Ensure unit is in a suitable environment. |
| Unpleasant odor in distilled water | New unit odor; Carbon filter needs replacement | Run a few cycles with fresh water to clear new unit odor. Replace carbon filter. |
If the problem persists after attempting these solutions, please contact CO-Z customer support for further assistance.
Specifications
| Feature | Detail |
|---|---|
| Brand | CO-Z |
| Model Number | DWD-EP01-00 |
| Capacity | 1.1 Gallons (4 Liters) |
| Power | 750W |
| Material | 304 Stainless Steel (Inner Container) |
| Product Dimensions | 47.02 x 27 x 29.01 cm (18.5 x 10.6 x 11.4 inches) |
| Item Weight | 4.56 Kilograms (9.8 lbs) |
| Color | White |
| Power Source Type | Corded Electric |
| Installation Method | Freestanding |
| Special Features | TDS Reduction, Timing Function, Reservation Function, Automatic Shut-off, High-speed Heat Dissipation |
| Purification Method | Distillation |
Warranty and Support
CO-Z products are manufactured to high-quality standards. For any questions, technical support, or warranty claims, please contact CO-Z customer service. Please have your model number (DWD-EP01-00) and purchase information ready when contacting support.