MABIS 40-742-000

MABIS Steam Inhaler with Facial and Nasal Mask

Model: 40-742-000

1. Important Safety Information

Please read all instructions carefully before using the MABIS Steam Inhaler. Failure to follow these instructions may result in injury or damage to the product.

2. Package Contents

Verify that all items are present in the package:

MABIS Steam Inhaler components including base, facial mask, nasal mask, and measuring cup.

Image: MABIS Steam Inhaler components, showing the main unit, facial mask, nasal mask, and measuring cup.

3. Setup Instructions

  1. Place the Base Unit: Position the steam inhaler base on a firm, level surface within easy reach of an electrical outlet.
  2. Fill the Water Reservoir: Use the provided measuring cup to pour 60ml of clean water into the reservoir of the base unit. Ensure the water level does not exceed the red fill line.
  3. A hand pouring water from a measuring cup into the MABIS Steam Inhaler's reservoir.

    Image: A hand pouring water into the steam inhaler's reservoir, demonstrating the correct water filling procedure.

  4. Attach the Desired Mask: Select either the facial attachment or the nasal attachment. Place it onto the base unit and turn clockwise to lock it securely in place.
  5. MABIS Steam Inhaler with both facial and nasal masks shown separately.

    Image: The MABIS Steam Inhaler base with both the facial attachment and the nasal attachment displayed.

  6. Connect to Power: Plug the power cord into a standard electrical outlet.

4. Operating Instructions

4.1 Using the Facial Steamer

  1. Ensure the facial attachment is securely locked onto the base unit.
  2. Press the power switch to turn on the unit. The switch will illuminate when active.
  3. Allow approximately 5-10 minutes for the water to heat and steam to begin producing.
  4. Slowly bring your face towards the facial attachment. Adjust your distance to achieve a comfortable and desired level of steam.
  5. A person using the MABIS Steam Inhaler with the facial mask attachment.

    Image: A user demonstrating the use of the facial mask attachment for steam therapy.

  6. Do not use for more than 15 minutes per session.
  7. After use, press the power switch to turn off the unit and unplug it from the outlet.

4.2 Using the Nasal Steamer

  1. Ensure the nasal attachment is securely locked onto the base unit.
  2. To extend the nasal attachment for a better fit, gently pull the top sides upwards and outwards.
  3. Two images showing the MABIS Steam Inhaler's nasal attachment being adjusted for height.

    Image: The nasal attachment shown in both its compact and extended positions, illustrating how to adjust it.

  4. Press the power switch to turn on the unit. The switch will illuminate when active.
  5. Allow approximately 5-10 minutes for the water to heat and steam to begin producing.
  6. Start with the steam control lever at the LOW setting. Increase the steam flow as needed for comfort.
  7. Slowly bring your nose and mouth towards the nasal attachment. Do not place your face fully onto the attachment. Adjust your distance to achieve a comfortable and desired level of steam for sinus relief.
  8. Do not use for more than 15 minutes per session.
  9. After use, press the power switch to turn off the unit and unplug it from the outlet.

Official Product Video: How to Use the MABIS Steam Inhaler

Video: This official MABIS Healthcare Inc. video demonstrates the proper setup and usage of the MABIS Steam Inhaler with both facial and nasal masks. It covers filling the water, attaching the masks, powering on, and adjusting steam for effective therapy.

5. Maintenance and Cleaning

Regular cleaning ensures optimal performance and hygiene of your MABIS Steam Inhaler.

6. Troubleshooting

If you encounter issues with your MABIS Steam Inhaler, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No steam producedUnit not plugged in or turned on; Insufficient water in reservoir; Unit is faulty.Ensure the power cord is securely plugged in and the power switch is in the 'ON' position (illuminated). Check that the water reservoir is filled to the correct level. If the issue persists, contact customer support.
Steam is weak or inconsistentLow water level; Mineral buildup in heating element; Steam control lever set too low (for nasal mask).Verify water level. Perform descaling if mineral buildup is suspected. Adjust the steam control lever to a higher setting if using the nasal mask.
Unit leaks waterWater reservoir overfilled; Attachment not securely locked.Ensure water is filled only up to the red line. Re-attach the mask, turning clockwise until it is firmly locked.
Power switch does not light upUnit not receiving power; Faulty switch.Check power outlet and cord connection. If power is confirmed and the switch still doesn't light, the unit may be faulty.

7. Product Specifications

SpecificationDetail
Model NameMabis Steam Inhaler with Facial Mask
Item Model Number40-742-000
BrandMABIS
Product Dimensions6.5 x 6.25 x 10.5 inches
Item Weight1.38 Pounds
Power SourceCorded Electric
Wattage60 watts
Voltage120 Volts
Capacity60 Milliliters
Runtime20 minutes (recommended max 15 minutes per session)
Material TypeAcrylonitrile Butadiene Styrene (ABS)
UPC767056181212
ManufacturerHealthSmart International
Diagram showing the dimensions of the MABIS Steam Inhaler with both facial and nasal attachments.

Image: A diagram illustrating the physical dimensions of the MABIS Steam Inhaler with both attachments.

8. Warranty and Support

For warranty information or technical support, please contact HealthSmart International, the manufacturer of the MABIS Steam Inhaler. Refer to the product packaging or their official website for current contact details and warranty terms.

Related Documents - 40-742-000

Preview MABIS Digital Thermometer User Manual and Care Guide
Comprehensive guide to using, caring for, and registering your MABIS Digital Thermometer. Includes instructions for oral, rectal, and axillary temperature readings, battery replacement, specifications, and warranty information.
Preview Dorman Window Lift Motor Kits - Comprehensive Application Guide
Explore the extensive range of Dorman Window Lift Motor Kits, designed for 100% new performance. This guide provides detailed application information for various makes and models, including Ford, GM, Chrysler, Nissan, Toyota, Honda, and more, ensuring you find the perfect fit for your vehicle.
Preview MABIS Deluxe Jumbo Display Digital Thermometer User Manual and Guide
User manual for the MABIS Deluxe Jumbo Display Digital Thermometer, providing instructions on usage, care, specifications, and warranty. Learn how to take accurate oral, axillary, and rectal temperatures.
Preview Mabis Digital Basal Thermometer: User Guide and Specifications
Comprehensive guide for the Mabis Digital Basal Thermometer, covering usage, care, troubleshooting, and specifications for accurate basal temperature tracking.
Preview Kinglucky i12 User Manual and FCC Compliance Information
This document provides FCC compliance information and user guidance for the Kinglucky i12 device, model number i12. It details FCC rules, potential interference, and user corrective measures.
Preview HealthSmart Pulse Oximeter FS10D FS10K FS20K User Manual and Instructions
Comprehensive instructions and specifications for the HealthSmart Pulse Oximeter models FS10D, FS10K, and FS20K. Learn about operation, safety, maintenance, and troubleshooting.