KAIWEETS KM401 Digital Multimeter User Manual

Model: KM401

Brand: KAIWEETS

1. Introduction

The KAIWEETS KM401 is a versatile and accurate digital multimeter designed for a wide range of electrical measurements. It features True RMS, 4000 counts display, and auto-ranging capabilities, making it suitable for electricians, automotive technicians, and DIY enthusiasts. This manual provides detailed instructions for safe and effective use of your KM401 multimeter.

KAIWEETS KM401 Digital Multimeter with test leads and batteries

Figure 1: KAIWEETS KM401 Digital Multimeter with included accessories.

2. Safety Information

Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the device.

3. Package Contents

Verify that all items are present in the package:

4. Setup

4.1 Battery Installation

The KM401 multimeter requires 3 AAA batteries for operation. If the batteries are not pre-installed, follow these steps:

  1. Ensure the multimeter is turned off.
  2. Locate the battery compartment cover on the back of the unit.
  3. Use a screwdriver to loosen the screw(s) and remove the cover.
  4. Insert the 3 AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Replace the battery compartment cover and secure it with the screw(s).

4.2 Connecting Test Leads

To prepare the multimeter for measurements:

  1. Insert the black test lead into the "COM" (common) input jack.
  2. Insert the red test lead into the appropriate input jack based on the measurement type:
    • For Voltage, Resistance, Continuity, Diode, Capacitance, Frequency, NCV, Live, and Temperature measurements, use the "VΩHz" jack.
    • For Current measurements up to 400mA, use the "mA" jack.
    • For Current measurements up to 10A, use the "10A" jack.

5. Operating Instructions

5.1 Power On/Off and Auto Shut Off

5.2 Function Selection

Rotate the central dial to select the desired measurement function. For functions with multiple modes (e.g., AC/DC Voltage, Diode/Continuity), press the FUNC button to cycle through the available modes.

KAIWEETS KM401 Digital Multimeter showing multi-function capabilities

Figure 2: The KM401 offers multiple measurement functions.

5.3 Measurements

5.3.1 AC/DC Voltage Measurement

Set the rotary dial to the V~ (AC Voltage) or V- (DC Voltage) position. Connect the test leads in parallel to the circuit or component to be measured. The display will show the voltage reading.

KAIWEETS KM401 measuring AC/DC Voltage and Current

Figure 3: Measuring AC/DC Voltage and Current with the KM401.

5.3.2 AC/DC Current Measurement

Set the rotary dial to the A~ (AC Current) or A- (DC Current) position, selecting either the mA or 10A input jack as appropriate. Connect the multimeter in series with the circuit to measure current. Ensure the circuit power is off before connecting.

5.3.3 Resistance Measurement

Set the rotary dial to the Ω (Resistance) position. Connect the test leads across the component to measure its resistance. Ensure the component is de-energized before measurement.

KAIWEETS KM401 performing Resistance, Capacitance, Diode, and Temperature tests

Figure 4: Various measurement capabilities including Resistance, Capacitance, Diode, and Temperature.

5.3.4 Continuity Test

Set the rotary dial to the Ω position and press FUNC to select continuity mode (indicated by a buzzer icon). Touch the test leads to the points to be tested. A continuous beep indicates continuity (low resistance).

5.3.5 Diode Test

Set the rotary dial to the Ω position and press FUNC to select diode mode (indicated by a diode symbol). Connect the red lead to the anode and the black lead to the cathode of the diode. The display shows the forward voltage drop.

5.3.6 Capacitance Measurement

Set the rotary dial to the F (Capacitance) position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before testing.

5.3.7 Frequency Measurement

Set the rotary dial to the Hz (Frequency) position. Connect the test leads to the signal source. The display will show the frequency in Hertz.

5.3.8 NCV (Non-Contact Voltage) Test

Set the rotary dial to the NCV position. Move the top of the multimeter near a live wire or electrical outlet. The meter will beep and the NCV indicator will light up if AC voltage is detected without direct contact.

KAIWEETS KM401 performing Live and NCV tests

Figure 5: Using the KM401 for Live wire detection and Non-Contact Voltage (NCV) testing.

5.3.9 Live Wire Detection

Set the rotary dial to the Live position. Insert the red test lead into the live wire socket or touch it to the live wire. The display will indicate if the wire is live.

5.3.10 Phase Sequence Detection

The KM401 can perform phase sequence detection. Set the rotary dial to the Phase position. Follow the on-screen prompts to connect the test leads to the phases. The meter will indicate the phase sequence.

KAIWEETS KM401 performing Phase Sequence Detection

Figure 6: The KM401's unique Phase Sequence Detection feature.

5.3.11 Temperature Measurement

Set the rotary dial to the °C/°F position. Connect the thermocouple to the input jacks, observing polarity. Place the thermocouple tip on the object or in the environment whose temperature is to be measured.

5.4 Special Functions

5.4.1 Data Hold

Press the HOLD button to freeze the current reading on the display. Press it again to release the hold function.

5.4.2 Backlight and Flashlight

Press the LIGHT button (often combined with the HOLD button) to turn on the display backlight for improved visibility in dim conditions. Some models also feature a built-in flashlight, activated by a separate button or a long press of the light button, to illuminate the work area.

KAIWEETS KM401 with flashlight and backlight activated

Figure 7: The KM401 features a backlight for the display and a built-in flashlight.

6. Maintenance

6.1 Cleaning

Wipe the multimeter casing with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is completely dry before use.

6.2 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.

6.3 Battery Replacement

When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate readings. Refer to Section 4.1 for battery installation instructions.

7. Troubleshooting

8. Specifications

SpecificationValue
BrandKAIWEETS
Model NumberKM401
Measurement TypeMultimeter, Voltmeter
Power SourceBattery Powered (3 AAA batteries included)
Item Weight350 Grams
Product Dimensions (L x W x H)19.3 x 11.5 x 5.6 Centimeters
Safety RatingIEC 61010-1:2000-1 CAT. IV 600V, CAT. III 1000V
Display Counts4000 Counts
True RMSYes
Auto-RangingYes
Auto Power OffYes
Low Battery IndicationYes
Overload ProtectionYes

9. Warranty and Support

KAIWEETS provides lifetime after-sale service and technical support for the KM401 Digital Multimeter. If you encounter any questions or problems while using the product, please do not hesitate to contact KAIWEETS customer support.

For assistance, please refer to the contact information provided on the KAIWEETS official website or your purchase platform.

Related Documents - KM401

Preview KAIWEETS HT118A Digital Multimeter User Manual
Comprehensive user manual for the KAIWEETS HT118A Digital Multimeter, covering safety instructions, product description, multimeter features, measurement functions, and specifications.
Preview Kaiweets KM601 Smart Digital Multimeter User Manual
Comprehensive user manual for the Kaiweets KM601 Smart Digital Multimeter, covering safety information, product features, measurement modes (SMART and MANUAL), terminal descriptions, maintenance, specifications, and warranty.
Preview KAIWEETS HT113B Digital Multimeter User Manual
Comprehensive user manual for the KAIWEETS HT113B Digital Multimeter, detailing its features, specifications, and operating instructions for accurate electrical testing.
Preview KAIWEETS KM100 Digital Multimeter User Manual
Comprehensive guide to the KAIWEETS KM100 Digital Multimeter, covering safety operations, meter diagram, functions, measurement procedures for DC/AC voltage, DC current, resistance, continuity, and diode testing, along with technical specifications and maintenance.
Preview KAIWEETS HT206D True-RMS Digital Clamp Meter User Manual
Comprehensive user manual for the KAIWEETS HT206D True-RMS Digital Clamp Meter. Learn about its features, safety information, operating instructions, and specifications for accurate electrical measurements.
Preview KAIWEETS HT206D Digital Clamp Meter User Manual and Specifications
Comprehensive user manual for the KAIWEETS HT206D digital clamp meter. Includes detailed instructions on operation, safety precautions, features, specifications, and maintenance for this T-RMS auto-ranging AC/DC clamp meter.