Franklin 2145079004S

Franklin 3/4 HP Deep Well Submersible Pump Motor Instruction Manual

Model: 2145079004S | Brand: Franklin

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Franklin 3/4 HP Deep Well Submersible Pump Motor, Model 2145079004S. Please read these instructions thoroughly before installation or operation to ensure proper function and longevity of the product.

Franklin 3/4 HP Deep Well Submersible Pump Motor

Image 1.1: Franklin 3/4 HP Deep Well Submersible Pump Motor. This image displays the cylindrical motor unit, primarily stainless steel, with electrical connection points and a splined shaft visible at the top.

2. Safety Information

Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. Failure to follow these instructions may result in serious injury or death.

  • Electrical Safety: Ensure all electrical connections are made by a qualified electrician and comply with local codes. Disconnect power before servicing.
  • Grounding: The motor must be properly grounded to prevent electric shock.
  • Water Quality: Do not use this pump for flammable liquids or in hazardous locations.
  • Lifting: Use appropriate lifting equipment when handling the pump motor due to its weight.
  • Temperature: Do not operate the motor in ambient temperatures exceeding 86°F (30°C).

3. Setup and Installation

Proper installation is crucial for the performance and longevity of your submersible pump motor. Consult a professional for installation if you are unsure about any steps.

  1. Pre-Installation Check: Verify that the motor specifications (voltage, HP, phase) match your power supply and pump requirements. Inspect the motor for any shipping damage.
  2. Motor-Pump Assembly: Carefully align and attach the motor to the pump end, ensuring the splined shaft engages correctly. Secure all fasteners according to the pump manufacturer's recommendations.
  3. Electrical Connections: Connect the motor leads (3 wires) to the control box or power supply. Ensure all connections are watertight and insulated using appropriate splicing kits for submersible applications.
  4. Grounding: Connect the motor's ground wire to a reliable earth ground.
  5. Lowering into Well: Use a strong, non-corrosive safety rope or cable attached to the pump assembly. Carefully lower the pump and motor into the well, ensuring it hangs freely and does not touch the well casing.
  6. Pipe Connection: Connect the discharge pipe to the pump outlet. Ensure all pipe connections are secure and leak-free.

4. Operation

Once installed, the motor is designed for continuous operation within its specified parameters.

  • Initial Start-up: After installation, prime the pump if necessary (refer to pump manual). Restore power to the system. The motor should start smoothly.
  • Monitoring: Observe the system for unusual noises, vibrations, or leaks during initial operation.
  • Water Level: Ensure the well water level remains above the pump intake during operation to prevent dry running, which can damage the motor.
  • Thermal Protection: The motor features automatic thermal protection. If the motor overheats, it will shut off and restart once it cools down. Investigate the cause of overheating if this occurs frequently.

5. Maintenance

The Franklin submersible pump motor is designed for minimal maintenance. However, periodic checks of the overall pumping system are recommended.

  • Annual System Check: Have a qualified technician inspect the entire well system annually, including the pump, motor, control box, and pressure tank.
  • Electrical Connections: Periodically check for loose or corroded electrical connections in the control box.
  • Water Quality: Monitor water quality for excessive sediment or abrasive particles, which can reduce pump and motor life.
  • Motor Housing: The corrosion-resistant stainless steel shell requires no specific maintenance.

6. Troubleshooting

Refer to the following table for common issues and their potential solutions. Always disconnect power before attempting any troubleshooting or repairs.

ProblemPossible CauseSolution
Motor does not startNo power; tripped breaker; faulty control box; wiring issue.Check power supply, reset breaker, inspect control box components, verify wiring connections.
Motor runs but no waterLow well water level; clogged pump intake; faulty pump end; air lock.Check well level, inspect pump intake, consult pump manual, bleed air from system.
Motor cycles frequentlyPressure tank issue; leaky plumbing; low well yield.Inspect pressure tank, check for leaks, assess well capacity.
Motor overheats and shuts offLow voltage; excessive load; insufficient cooling flow; dry running.Verify voltage, reduce load if possible, ensure proper water flow around motor, check well level.

7. Technical Specifications

Detailed specifications for the Franklin 3/4 HP Deep Well Submersible Pump Motor, Model 2145079004S.

SpecificationValue
ItemDeep Well Submersible Pump Motor
Motor ApplicationPumps
Motor Sub ApplicationDeep Well Submersible Pumps
Motor TypeCapacitor-Start
EnclosureTotally Enclosed Nonventilated
Horsepower (HP)3/4
Nameplate RPM3450
Voltage230V
Phase1
Full Load Amps6.8 A
Max. Service Factor Amps8.0 A
Frequency (Hz)60 Hz
Service Factor1.5
Max. Ambient Temperature86°F (30°C)
Thrust Rating300 lb.
Number of Wires3
Thermal ProtectionAuto
RotationCCWSE (Counter-Clockwise Shaft End)
Diameter4 inches
Diaphragm TypePressure Equalizing
Shaft MaterialSplined Stainless Steel
Shell MaterialCorrosion Resistant Stainless Steel
Stator TypeHermetically Sealed
Lead Length48 inches
Height10-5/8 inches
RPM Range3001-3600
Part Number2145079004S
ASINB096BFMDN2
Date First AvailableJune 1, 2021

8. Warranty and Customer Support

For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized Franklin dealer. Keep your purchase receipt as proof of purchase.

For technical assistance or customer support, please contact your product supplier or an authorized service center. When contacting support, please have your model number (2145079004S) and purchase date readily available.

Related Documents - 2145079004S

Preview Franklin BT01 PRO Mini Bluetooth Speaker User Manual
Comprehensive user manual for the Franklin BT01 PRO Mini Bluetooth Speaker, covering charging, Bluetooth pairing, stereo mode, mode switching, specifications, and FCC compliance.
Preview Franklin ProShot Pickleballer 52879 - Assembly, Instructions, and Game Guide
Official assembly instructions, care guide, and playing rules for the Franklin ProShot Pickleballer (Item #52879). Learn how to set up, maintain, and play pickleball with this automatic ball launcher.
Preview Franklin Ladderball Game: Rules, Assembly, and Court Setup
Comprehensive guide to Franklin Ladderball (Item Numbers 52018, 52018X), including game rules, official scoring, assembly instructions, parts list, and court layout. Learn how to play and set up your ladderball game.
Preview Franklin PRO PORTA BATTING TEE 24847 - Assembly Instructions & Parts List
Official assembly instructions and parts list for the Franklin PRO PORTA BATTING TEE (Model 24847). Learn how to set up and adjust your batting tee. Includes customer service contact information.
Preview Franklin Deluxe LG Return 24807X: Assembly Instructions and Product Information
Comprehensive guide for assembling the Franklin Deluxe LG Return (Item #24807X), including parts list, assembly steps, customer service information, and safety precautions. Features Major League Baseball branding.
Preview Franklin 19" x 29" Folding Platform Truck Owner's Manual & Safety Instructions
This manual provides safety warnings, precautions, assembly, operating, inspection, maintenance, and cleaning procedures for the Franklin 19" x 29" Folding Platform Truck (Item 58300).