ESSEBAGNO 9017268

Essebagno Luisa Mechanical Shower Column - User Manual

Model: 9017268 | Finish: Brushed Gold

Introduction

Thank you for choosing the Essebagno Luisa Mechanical Shower Column. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new shower column. Please read these instructions carefully before installation and keep them for future reference.

Safety Information

  • Ensure all water supply valves are closed before beginning installation.
  • If you are unsure about any part of the installation process, consult a qualified plumber.
  • Do not use abrasive cleaners or materials on the brushed gold finish, as this may damage the surface.
  • Regularly check for leaks and ensure all connections are secure.

Setup and Installation

Follow these steps for proper installation of your Essebagno Luisa shower column:

  1. Preparation: Before assembly, thoroughly flush the hot and cold water pipes to prevent dirt and residue from compromising the proper functioning of the faucet.
  2. Remove Old Fixture: After closing the main water supply, carefully remove the old faucet.
  3. Clean Connections: Thoroughly clean the threads of the main water supply pipes.
  4. Mounting: Install the shower column to the wall using the provided eccentric connectors and rosettes. Ensure a secure and watertight fit.
Technical diagram of Essebagno Luisa shower column with dimensions

Figure 1: Technical diagram showing the dimensions and components of the shower column.

Essebagno Luisa shower column installed in a modern bathroom

Figure 2: Example of the Essebagno Luisa shower column installed.

Operating Instructions

Water Flow and Temperature Control

The Essebagno Luisa shower column features a mechanical mixer for controlling water flow and temperature. Rotate the main handle to adjust the water temperature from cold to hot. Lift or push the handle to control the water flow intensity.

Close-up of the mechanical mixer handle on the Essebagno Luisa shower column

Figure 3: Close-up view of the mechanical mixer handle for temperature and flow control.

Switching Between Shower Head and Hand Shower

To switch between the overhead shower head and the hand shower, use the diverter knob located on the main column. Rotate the knob to direct water flow to your desired outlet.

Close-up of the diverter knob on the Essebagno Luisa shower column

Figure 4: The diverter knob allows switching between the overhead shower and hand shower.

Adjusting Hand Shower Height

The hand shower holder is adjustable along the shower column. Press the button or lever on the holder to slide it up or down to your preferred height. Release to lock it in place.

Diagram showing how to adjust the height of the hand shower holder

Figure 5: Steps to adjust the hand shower holder height.

Maintenance and Care

Proper maintenance will ensure the longevity and appearance of your shower column.

  • Daily Cleaning: To keep your shower column clean and shiny, we recommend wiping it with a microfiber cloth immediately after use.
  • Limescale Prevention: You can also use a descaling cleaner with a microfiber cloth to prevent limescale deposits.
  • Avoid Abrasives: It is strongly advised not to use abrasive products, scouring pads, or harsh chemicals, as these can damage the brushed gold finish.
  • Anti-Limescale Nozzles: The hand shower and overhead shower head are equipped with anti-limescale nozzles for easy cleaning. Gently rub the silicone nozzles to dislodge any limescale buildup.

Troubleshooting

If you encounter issues with your Essebagno Luisa shower column, refer to the following common solutions:

ProblemPossible CauseSolution
Low water pressurePartially closed stopcock; clogged aerator/nozzles; pipe blockage.Ensure stopcocks are fully open. Clean shower head and hand shower nozzles. Check for blockages in supply lines.
Water temperature inconsistentInconsistent hot/cold water supply; mixer cartridge issue.Check household hot water supply. If problem persists, contact a qualified plumber to inspect or replace the mixer cartridge.
Leaks from connectionsLoose connections; worn seals/washers.Tighten connections carefully. Replace any damaged seals or washers. Do not overtighten.
Difficulty switching between outletsDiverter mechanism stiff or faulty.Apply a small amount of silicone grease to the diverter mechanism if accessible. If it remains stiff or faulty, professional inspection may be required.

If these solutions do not resolve the issue, please contact customer support.

Specifications

FeatureDetail
BrandESSEBAGNO
Model Number9017268
ColorBrushed Gold
MaterialBrass
Finish TypeBrushed
Number of Handles1
Handle MaterialMetal
Item Weight4.24 Kilograms
Mounting TypeWall Mount
Included ComponentsShower column, mechanical mixer, ultra-flat shower head, and 150 cm hose
Head Size250 mm
ManufacturerEssebagno
Part Number10018517
Sanitary ConformityACS Certified (Accréditation de Conformité Sanitaire)
Boiler CompatibilityCompatible with all types of boilers

Warranty Information

Please refer to your purchase documentation or contact Essebagno customer service for detailed warranty information regarding your shower column. Keep your proof of purchase for any warranty claims.

Customer Support

For further assistance, technical support, or to inquire about replacement parts, please contact Essebagno customer service. Contact details can typically be found on the manufacturer's website or your product packaging.