Introduction
Thank you for choosing the Essebagno Luisa Mechanical Shower Column. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new shower column. Please read these instructions carefully before installation and keep them for future reference.
Safety Information
- Ensure all water supply valves are closed before beginning installation.
- If you are unsure about any part of the installation process, consult a qualified plumber.
- Do not use abrasive cleaners or materials on the brushed gold finish, as this may damage the surface.
- Regularly check for leaks and ensure all connections are secure.
Setup and Installation
Follow these steps for proper installation of your Essebagno Luisa shower column:
- Preparation: Before assembly, thoroughly flush the hot and cold water pipes to prevent dirt and residue from compromising the proper functioning of the faucet.
- Remove Old Fixture: After closing the main water supply, carefully remove the old faucet.
- Clean Connections: Thoroughly clean the threads of the main water supply pipes.
- Mounting: Install the shower column to the wall using the provided eccentric connectors and rosettes. Ensure a secure and watertight fit.

Figure 1: Technical diagram showing the dimensions and components of the shower column.

Figure 2: Example of the Essebagno Luisa shower column installed.
Operating Instructions
Water Flow and Temperature Control
The Essebagno Luisa shower column features a mechanical mixer for controlling water flow and temperature. Rotate the main handle to adjust the water temperature from cold to hot. Lift or push the handle to control the water flow intensity.

Figure 3: Close-up view of the mechanical mixer handle for temperature and flow control.
Switching Between Shower Head and Hand Shower
To switch between the overhead shower head and the hand shower, use the diverter knob located on the main column. Rotate the knob to direct water flow to your desired outlet.

Figure 4: The diverter knob allows switching between the overhead shower and hand shower.
Adjusting Hand Shower Height
The hand shower holder is adjustable along the shower column. Press the button or lever on the holder to slide it up or down to your preferred height. Release to lock it in place.

Figure 5: Steps to adjust the hand shower holder height.
Maintenance and Care
Proper maintenance will ensure the longevity and appearance of your shower column.
- Daily Cleaning: To keep your shower column clean and shiny, we recommend wiping it with a microfiber cloth immediately after use.
- Limescale Prevention: You can also use a descaling cleaner with a microfiber cloth to prevent limescale deposits.
- Avoid Abrasives: It is strongly advised not to use abrasive products, scouring pads, or harsh chemicals, as these can damage the brushed gold finish.
- Anti-Limescale Nozzles: The hand shower and overhead shower head are equipped with anti-limescale nozzles for easy cleaning. Gently rub the silicone nozzles to dislodge any limescale buildup.
Troubleshooting
If you encounter issues with your Essebagno Luisa shower column, refer to the following common solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Low water pressure | Partially closed stopcock; clogged aerator/nozzles; pipe blockage. | Ensure stopcocks are fully open. Clean shower head and hand shower nozzles. Check for blockages in supply lines. |
| Water temperature inconsistent | Inconsistent hot/cold water supply; mixer cartridge issue. | Check household hot water supply. If problem persists, contact a qualified plumber to inspect or replace the mixer cartridge. |
| Leaks from connections | Loose connections; worn seals/washers. | Tighten connections carefully. Replace any damaged seals or washers. Do not overtighten. |
| Difficulty switching between outlets | Diverter mechanism stiff or faulty. | Apply a small amount of silicone grease to the diverter mechanism if accessible. If it remains stiff or faulty, professional inspection may be required. |
If these solutions do not resolve the issue, please contact customer support.
Specifications
| Feature | Detail |
|---|---|
| Brand | ESSEBAGNO |
| Model Number | 9017268 |
| Color | Brushed Gold |
| Material | Brass |
| Finish Type | Brushed |
| Number of Handles | 1 |
| Handle Material | Metal |
| Item Weight | 4.24 Kilograms |
| Mounting Type | Wall Mount |
| Included Components | Shower column, mechanical mixer, ultra-flat shower head, and 150 cm hose |
| Head Size | 250 mm |
| Manufacturer | Essebagno |
| Part Number | 10018517 |
| Sanitary Conformity | ACS Certified (Accréditation de Conformité Sanitaire) |
| Boiler Compatibility | Compatible with all types of boilers |
Warranty Information
Please refer to your purchase documentation or contact Essebagno customer service for detailed warranty information regarding your shower column. Keep your proof of purchase for any warranty claims.
Customer Support
For further assistance, technical support, or to inquire about replacement parts, please contact Essebagno customer service. Contact details can typically be found on the manufacturer's website or your product packaging.