Winco SCAL-D22

Winco SCAL-D22 Digital Portion Control Scale User Manual

Model: SCAL-D22

Introduction

Thank you for choosing the Winco SCAL-D22 Digital Portion Control Scale. This manual provides essential information for the proper setup, operation, and maintenance of your new scale. Please read these instructions thoroughly before use to ensure accurate measurements and extend the lifespan of your device.

Important Safety Information

Package Contents

Please check the package for the following items:

Product Overview

Familiarize yourself with the components of your Winco SCAL-D22 scale:

Winco SCAL-D22 Digital Portion Control Scale with stainless steel platform and control panel

Image 1: Winco SCAL-D22 Digital Portion Control Scale. The scale features a stainless steel weighing platform, a digital LCD display, and a control panel with various function buttons.

Setup

  1. Unpack the Scale: Carefully remove all components from the packaging.
  2. Install Batteries (Optional): If using battery power, open the battery compartment on the underside of the scale. Insert three (3) AAA batteries, ensuring correct polarity (+/-). Close the compartment securely.
  3. Connect AC Adapter (Optional): For continuous power, plug the AC adapter into the scale's power port and then into a standard electrical outlet. The scale can operate on either battery or AC power.
  4. Place Platform: Position the stainless steel weighing platform securely onto the scale base.
  5. Placement: Place the assembled scale on a firm, level, and stable surface, away from vibrations or drafts.

Operating Instructions

Power On/Off

Unit Conversion

Tare Function

The Tare function allows you to subtract the weight of a container, so only the weight of the contents is measured.

  1. Place an empty container on the weighing platform. The display will show its weight.
  2. Press the TARE button. The display will reset to "0.000", indicating the container's weight has been tared.
  3. Add items to the container. The display will now show only the net weight of the items.
  4. To clear the tare, remove the container from the platform and press the TARE button again.

Piece Counting Function

This function allows you to count a large number of small, uniformly weighted items.

  1. Turn on the scale and ensure the display reads "0.000".
  2. Place a known quantity of items (e.g., 10, 20, 50, or 100 pieces) on the platform.
  3. Press and hold the COUNT button until "PCS" appears on the display, followed by a flashing number (e.g., "10 PCS"). This indicates the sample size.
  4. Use the UNIT button to select the sample size that matches the number of items you placed on the platform.
  5. Press the COUNT button again to confirm the sample size. The display will now show the count of the items.
  6. You can now add more items, and the scale will display the total count.
  7. To exit piece counting mode, press the COUNT button again.

Field Calibration

The scale features a field calibration function. Refer to the specific instructions provided with your scale or contact Winco customer support for detailed steps on performing calibration, as this process typically requires specific calibration weights and precise execution.

Maintenance and Care

Troubleshooting

If you encounter issues with your scale, please refer to the following common problems and solutions:

ProblemPossible CauseSolution
Scale does not turn on.
  • Dead or incorrectly installed batteries.
  • AC adapter not properly connected.
  • Replace batteries or check polarity.
  • Ensure AC adapter is securely plugged into both the scale and the outlet.
Inaccurate readings.
  • Scale not on a level surface.
  • Overloaded scale.
  • External vibrations or drafts.
  • Needs calibration.
  • Place on a stable, level surface.
  • Do not exceed 22 lb capacity.
  • Move scale to a stable environment.
  • Perform field calibration if necessary (refer to specific instructions).
Display shows "EEEE" or "O_Ld".Scale is overloaded.Remove items immediately to prevent damage. Do not exceed 22 lb capacity.
Tare function not working.Possible internal error or button malfunction.Try turning the scale off and on again. If the issue persists, contact customer support.

Specifications

FeatureDetail
ModelSCAL-D22
Capacity22 Pounds (approx. 10 kg)
Display2.5 x 1 inch LCD with Backlight
Platform Size6 x 6 inches, Stainless Steel, Removable
Housing MaterialPlastic
Power Source(3) AAA Batteries or AC Adapter (included)
FunctionsUnit Conversion, Tare, Piece Count, Field Calibration, Auto-Off (battery mode)
CertificationsNSF
Product Dimensions8.89 x 6.06 x 1.65 inches
Product Weight1.19 Pounds

Warranty and Support

For information regarding warranty coverage, technical support, or replacement parts for your Winco SCAL-D22 Digital Portion Control Scale, please contact Winco customer service directly. Refer to the product packaging or the official Winco website for the most current contact information.

Winco is committed to providing quality products and support.

Related Documents - SCAL-D22

Preview Winco SCAL-D22 Digital Portion Scale: Operating Instructions and Specifications
Comprehensive operating instructions, specifications, features, and safety guidelines for the Winco SCAL-D22 Digital Portion Scale. Learn how to use, calibrate, and maintain your scale for accurate weighing.
Preview Winco SCAL-D22 Digital Portion Scale Operating Instructions
Operating instructions and specifications for the Winco SCAL-D22 digital portion scale, including care, usage, functions, and safety information.
Preview WINCO W6010DE/J Generator Parts List and Diagrams
Comprehensive parts list and assembly diagrams for the WINCO W6010DE/J portable generator. Includes detailed breakdowns of the engine, generator end, cradle assembly, fuel system, electrical receptacles, and decals, with part numbers and quantities.
Preview Winco TDAC-8W/TDAC-8K Paper Towel Dispenser Instructions
This document provides instructions for mounting, filling, and locking the Winco TDAC-8W and TDAC-8K paper towel dispensers.
Preview Winco 18" Pizza/Pretzel Warmer Model 51018 - Operating Manual and Specifications
Comprehensive operating manual, safety instructions, parts list, and wiring diagram for the Winco 18" Pizza/Pretzel Warmer, Model 51018. Learn how to safely operate, maintain, and assemble your commercial food warmer.
Preview Winco Hot Dog Roller Grill User Manual and Operating Instructions
This document provides essential safety, operating, and cleaning instructions for the Winco Hot Dog Roller Grill models 62010, 62020, and 62030. It also includes a wiring diagram and a comprehensive parts list.