This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Dibea UV-10 Corded Handheld Bed Vacuum Cleaner. Please read this manual thoroughly before first use and retain it for future reference.
The Dibea UV-10 is designed for cleaning mattresses, upholstery, and other fabric surfaces, featuring a powerful motor, roller brush, and a multi-stage filtration system to capture dust and allergens.
2. Safety Instructions
- Ensure the power cord and plug are undamaged before each use. Do not operate the vacuum with a damaged cord or plug.
- Do not use the vacuum cleaner on wet surfaces or to pick up liquids. This appliance is for dry use only.
- Keep hair, loose clothing, fingers, and all parts of the body away from openings and moving parts.
- Do not pick up flammable or combustible materials, hot ashes, or sharp objects.
- Always unplug the vacuum cleaner from the electrical outlet before cleaning or performing maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Use only as described in this manual. Use only manufacturer's recommended attachments.
3. Product Components
Familiarize yourself with the main components of your Dibea UV-10 Bed Vacuum Cleaner:
- Main Unit (Motor Housing, Handle)
- Dust Cup Assembly (with Cyclone Separator)
- HEPA Filter
- Roller Brush Head
- Power Cord

The image above displays the complete Dibea UV-10 unit. The transparent dust cup allows for easy monitoring of dust accumulation, and the circular HEPA filter is visible at the top of the dust cup, indicating its position within the filtration system.
4. Setup
The Dibea UV-10 Bed Vacuum Cleaner comes pre-assembled for immediate use. No complex assembly is required.
- Unpack: Carefully remove the vacuum cleaner and all accessories from the packaging.
- Inspect: Check the unit for any signs of damage. If damaged, do not use and contact customer support.
- Power Connection: Unwind the power cord and plug it into a suitable electrical outlet (120V AC). Ensure the cord is not tangled or obstructed during operation.
5. Operating Instructions
The Dibea UV-10 is designed for efficient cleaning of fabric surfaces.
- Power On: Press the power button located on the handle to turn on the vacuum cleaner.
- Cleaning Technique: Gently glide the vacuum cleaner over the surface you wish to clean. The integrated soft roller brush and high-frequency vibration (up to 33,000 cycles/min) will agitate and loosen embedded dust and debris, while the powerful 300W motor provides strong suction (10,000Pa).

As shown in Figure 5.1, the vacuum is operated by moving it across the surface. The soft roller brush is designed to effectively clean without damaging fabrics. The blue arrows indicate the direction of airflow and suction.

Figure 5.2 details the core cleaning technology: a 300W motor generating 10,000Pa suction and a vibration mechanism operating at 33,000 cycles per minute. This combination ensures thorough removal of dust and particles from deep within fabric fibers.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your Dibea UV-10.
6.1 Emptying and Cleaning the Dust Cup
The 400ml transparent dust bin should be emptied after each use or when the MAX fill line is reached.
- Release Handle: Press the button on the handle to release the main unit from the roller brush head.
- Unlock Dust Cup: Twist the dust cup counter-clockwise to unlock it from the main unit.
- Remove Filters: Carefully remove the HEPA filter and other internal filters from the dust cup.
- Empty Dust: Empty the collected dust and debris into a waste bin.
- Wash Components: The dust cup and filters (except the main motor unit) can be rinsed with water. Ensure all components are completely dry before reassembling.
- Reassemble: Reinsert the dry filters, attach the dust cup by twisting clockwise until locked, and reattach the main unit to the roller brush head.

Figure 6.1 visually guides you through the process: pressing the release button, twisting to unlock the dust cup, removing filters, and finally, emptying and washing the components. Always ensure parts are dry before reassembly.
6.2 Filtration System
The Dibea UV-10 features a 6-stage filtration system designed to capture 99.9% of particles as small as 0.3 microns, releasing fresh air.

Figure 6.2 provides an exploded view of the filtration system. Regular cleaning of the Primary Cotton Filter, HEPA Precision Filtration, Inlet Cotton Filtration, and Outlet Cotton Filtration is crucial. These filters can be gently rinsed with water and must be completely air-dried before being placed back into the vacuum. Do not wash the Internal Motor Filter.
6.3 Roller Brush Cleaning
Periodically check the roller brush for tangled hair or debris. Use scissors or the included cleaning tool to carefully cut and remove any obstructions. Ensure the brush spins freely.
7. Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Vacuum does not turn on | No power supply; Power button not pressed | Check power cord connection; Ensure outlet is functional; Press power button firmly |
| Low suction power | Dust cup full; Filters clogged; Obstruction in nozzle/hose | Empty dust cup; Clean all filters thoroughly; Remove any blockages from the roller brush head or suction path |
| Unusual noise during operation | Obstruction in roller brush; Damaged component | Clean roller brush for tangled hair/debris; If noise persists, discontinue use and contact support |
| Dust escaping from vacuum | Dust cup not properly sealed; Filters not correctly installed or damaged | Ensure dust cup is securely locked; Check filter installation and condition, replace if damaged |
8. Specifications
- Model: UV-10
- Brand: Dibea
- Power: 300 Watts
- Form Factor: Handheld
- Color: White
- Noise Level: 70 Decibels
- Capacity: 0.4 Liters (Dust Bin)
- Filter Type: HEPA Filter
- Special Feature: HEPA Filtration
- Cord Length: Approximately 4.5 meters
- Product Dimensions: 12.2 x 8.67 x 10.24 inches
- Item Weight: 4.1 pounds
- Indoor/Outdoor Usage: Indoor
9. Warranty and Support
For warranty information, product support, or to inquire about replacement parts, please refer to the warranty card included with your purchase or contact Dibea customer service directly. Contact details are typically available on the manufacturer's official website or through your point of purchase.