1. Product Overview

The Elitech LogEt 8 BLE is a Bluetooth wireless multi-use PDF data logger designed for monitoring temperature in various life science applications. It features a USB port for direct data download and PDF report generation, and Bluetooth connectivity for remote management via the Elitech App.

Key Features:

  • Wireless Bluetooth Technology: Enables one-click pairing and remote programming/management via the Elitech App within meters.
  • Wide Temperature Measuring Range: -22℉ to 158℉ (-30℃ to 70℃) with an accuracy of ±0.9℉ (±0.5℃).
  • Mobile App Compatibility: Free Elitech App for iOS and Android devices facilitates remote logger management and cold chain monitoring.
  • Multi-use Capability: Designed for repeated use over approximately 2 years under room temperature conditions.
  • Automatic Data Synchronization: Automatically uploads all recorded data to your account when connected to the Elitech APP.
  • High Recording Capacity: Stores up to 16,000 recording points.
Front view of Elitech LogEt 8 BLE data logger with labeled components: USB Port, LCD Screen, START Button, STOP Button, Embedded Temperature Sensor.

Figure 1: Front view of the LogEt 8 BLE data logger with labeled components.

2. Package Contents

Verify that all items are present in the package upon unboxing:

  • 1 x LogEt 8 BLE Data Logger
  • 1 x User Manual
  • 1 x Calibration Certificate
Image showing the Elitech LogEt 8 BLE data logger package contents, including the data logger, user manual, and calibration certificate.

Figure 2: Contents included in the LogEt 8 BLE package.

3. Device Components

Familiarize yourself with the main components of the LogEt 8 BLE data logger:

  • USB Port: Located at the top, protected by a removable cap. Used for direct connection to a computer for data download and configuration.
  • LCD Screen: Displays current temperature, alarm status, recording status, and battery level.
  • START Button: Initiates data recording.
  • STOP Button: Halts data recording.
  • Embedded Temperature Sensor: Internal sensor for accurate temperature measurement.

4. Setup

4.1 Initial Setup

  1. Unpack the Device: Carefully remove the LogEt 8 BLE from its packaging.
  2. Inspect for Damage: Check the device for any visible damage. If damaged, contact customer support.
  3. Battery Activation: The device comes with a pre-installed lithium metal battery. No initial activation is typically required.

4.2 Software Installation (Elitech App)

To fully utilize the LogEt 8 BLE's features, download the Elitech App on your mobile device:

  • Search for "Elitech" in the Apple App Store (for iOS) or Google Play Store (for Android).
  • Download and install the official Elitech App.
  • Create an account or log in if you already have one.

4.3 Connecting via Bluetooth

Once the app is installed:

  1. Ensure Bluetooth is enabled on your mobile device.
  2. Open the Elitech App.
  3. The app will scan for nearby Elitech data loggers. Select your LogEt 8 BLE from the list to pair.
  4. Follow any on-screen prompts for one-click pairing.

4.4 Programming the Logger

Before starting a recording, configure the logger's parameters using the Elitech App or by connecting directly to a computer via USB:

  • Via Elitech App: Within the app, navigate to the settings for your connected LogEt 8 BLE. You can set parameters such as sampling interval, alarm thresholds, start delay, and recording duration.
  • Via USB (PC Software): Remove the protective cap to expose the USB port. Connect the logger to a computer. Use the Elitech data management software (downloadable from the Elitech website) to configure settings.
Side view of Elitech LogEt 8 BLE data logger showing a default parameters sticker with alarm settings, start-up delay, record day, and data sampling interval.

Figure 3: Default parameters sticker on the side of the device.

5. Operating Instructions

5.1 Starting a Recording

To begin data logging:

  • Press and hold the START button for approximately 3 seconds until the "REC" indicator appears on the LCD screen.
  • If a start delay was configured, the logger will begin recording after the specified delay.

5.2 Stopping a Recording

To end data logging:

  • Press and hold the STOP button for approximately 3 seconds until the "END" indicator appears on the LCD screen.
  • Alternatively, connect the logger to the Elitech App or PC software and select the option to stop recording.

5.3 Data Download and Report Generation

After recording, data can be retrieved and analyzed:

  • Via USB: Remove the USB cap and plug the logger into a computer's USB port. The logger will automatically generate a PDF report and a CSV data file. These files can be accessed directly from the logger's virtual drive.
  • Via Elitech App: Connect the logger to the Elitech App via Bluetooth. The app will automatically sync and upload all data to your account. You can then view graphs, export data, or generate reports directly from the app.
Elitech LogEt 8 BLE data logger with USB port exposed, displaying temperature in Fahrenheit, and indicating temperature range (-30°C/-22°F to 70°C/158°F) and 16000 points record capacity.

Figure 4: LogEt 8 BLE with USB port exposed and key specifications.

6. Maintenance

6.1 Battery Information

The LogEt 8 BLE is powered by a non-rechargeable lithium metal battery. The battery is designed to last for approximately 2 years under normal operating conditions. The battery is contained within the equipment and is not user-serviceable. Attempting to replace the battery may damage the device and void the warranty.

6.2 Cleaning

To clean the device:

  • Wipe the exterior with a soft, dry cloth.
  • Do not use abrasive cleaners, solvents, or immerse the device in water.

6.3 Storage

When not in use, store the data logger in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

If you encounter issues with your LogEt 8 BLE, refer to the following common problems and solutions:

  • Device not turning on: Check battery level on the LCD. If the battery is depleted, the device may need replacement as the battery is not user-serviceable.
  • Unable to connect via Bluetooth: Ensure Bluetooth is enabled on your mobile device and the Elitech App is open. Make sure the logger is within range. Restart both the logger and your mobile device.
  • No data recorded: Verify that recording was properly started (check for "REC" on LCD). Ensure the logger's memory is not full.
  • PDF report not generated: Ensure the logger is connected to a computer's USB port correctly. Try a different USB port or computer. Ensure the USB cap is fully removed.
  • Inaccurate readings: Ensure the logger's sensor is not obstructed and is placed in an environment suitable for its operating range.

For further assistance, contact Elitech customer support.

8. Specifications

FeatureSpecification
Model NumberLogEt 8 BLE
Temperature Measuring Range-30℃ to 70℃ (-22℉ to 158℉)
Temperature Accuracy±0.5℃ (±0.9℉)
Recording Capacity16,000 points
ConnectivityBluetooth, USB
Power Source1 x Lithium Metal battery (included, non-replaceable)
Special FeatureAlarm Functionality
Item Weight60 g
Product Dimensions9.98 x 4.6 x 1.88 cm (3.93 x 1.81 x 0.74 inches)
Country of OriginUSA
Hardware Interface TypeUSB

9. Warranty and Support

9.1 Warranty Information

Elitech products typically come with a limited warranty covering manufacturing defects. Please refer to the warranty card included in your package or visit the official Elitech website for specific warranty terms and conditions applicable to the LogEt 8 BLE.

9.2 Customer Support

For technical support, troubleshooting assistance, or warranty claims, please contact Elitech customer service:

  • Website: Visit www.elitechus.com for FAQs, software downloads, and contact information.
  • Email/Phone: Refer to the Elitech website or your product packaging for the most current contact details.

© 2024 Elitech. All rights reserved.

Related Documents - LogEt 8 BLE

Preview Elitech LogEt 8 Series Data Logger User Manual - Temperature and Humidity Monitoring
Comprehensive user manual for the Elitech LogEt 8 Series data loggers, detailing specifications, operation, installation, and troubleshooting for temperature and humidity monitoring in cold chain logistics.
Preview Elitech LogEt 1 Series Single-Use PDF Data Logger User Manual
User manual for the Elitech LogEt 1, LogEt 1TH, and LogEt 1Bio single-use PDF data loggers, covering appearance, technical specifications, indication instructions, and operation.
Preview Elitech LogEt 5 Series Data Logger Specifications and User Manual
Comprehensive specifications, features, and operating instructions for the Elitech LogEt 5 series of temperature and humidity data loggers, designed for cold chain monitoring.
Preview Elitech LogEt 260 Series Instruction Manual - Temperature, Light, Vibration Data Loggers
Comprehensive instruction manual for the Elitech LogEt 260 series data loggers, covering safety, product features, selection, technical parameters, operation, and LED indicators. Features temperature, light, vibration monitoring, and 4G connectivity.
Preview Elitech LogEt 5 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 5 Series temperature and humidity data loggers. Covers overview, model selection, specifications, operation, status indication, battery replacement, and default configurations.
Preview Elitech LogEt 1 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 1 series of single-use data loggers, covering LogEt 1 (temperature), LogEt 1TH (temperature-humidity), and LogEt 1 Bio (high accuracy temperature). Includes specifications, operation, status indication, and warnings.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.