1. Introduction
This manual provides essential instructions for the safe and proper installation, operation, and maintenance of the Hubbell 8460A 60A 250-Volt Single Receptacle. This genuine OEM replacement part is designed for high-quality performance in various applications requiring a 60 Amp, 250 Volt connection. Please read all instructions carefully before proceeding with installation or use.
Safety Warning:
- Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing this device.
- Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
2. Product Overview
The Hubbell 8460A is a durable single receptacle designed for demanding electrical applications. It features a robust construction to ensure reliable power delivery.
Figure 1: Angled front view of the Hubbell 8460A receptacle, showing the faceplate and NEMA 15-60R configuration. Two mounting screws are visible beside it.
Figure 2: Straight-on front view of the Hubbell 8460A receptacle, clearly displaying the NEMA 15-60R configuration and Hubbell branding. Two mounting screws are shown below the receptacle.
3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of the Hubbell 8460A receptacle. Ensure all local and national electrical codes are strictly followed.
3.1 Tools and Materials Required:
- Screwdrivers (Phillips and flat-head)
- Wire strippers
- Voltage tester
- Electrical tape
- Appropriate electrical box (gang box)
- Conduit and fittings (if applicable)
3.2 Wiring Instructions:
- Disconnect Power: Locate the circuit breaker or fuse controlling the circuit where the receptacle will be installed. Turn off the power completely and verify with a voltage tester that the power is off.
- Prepare Wires: Strip approximately 1/2 inch (12-15mm) of insulation from the ends of the electrical wires (Line 1, Line 2, and Ground). Ensure the wire gauge is appropriate for 60A service (e.g., 6 AWG copper wire).
- Connect Wires:
Figure 3: Rear view of the Hubbell 8460A receptacle, illustrating the screw terminals for wiring connections. The 'GREEN' terminal for ground is clearly marked.
- Connect the ground wire (typically green or bare copper) to the green screw terminal on the receptacle.
- Connect the Line 1 wire (typically black or red) to one of the brass screw terminals.
- Connect the Line 2 wire (typically black or red) to the other brass screw terminal.
- Ensure all connections are tight and secure. Do not overtighten.
- Mount Receptacle: Carefully fold the wires into the electrical box. Align the receptacle with the mounting holes in the electrical box and secure it with the provided screws.
- Restore Power: Once the receptacle is securely mounted and all connections are verified, restore power at the circuit breaker.
- Test: Use a voltage tester to confirm proper voltage at the receptacle.
Figure 4: Side view of the Hubbell 8460A receptacle, revealing the robust internal contact design for secure and reliable electrical connections.
4. Operating Instructions
The Hubbell 8460A receptacle is designed for straightforward operation once correctly installed.
- Ensure the appliance or equipment to be connected is compatible with a 60A, 250V NEMA 15-60P plug.
- Align the plug with the receptacle openings and insert firmly.
- To disconnect, grasp the plug body and pull it straight out from the receptacle. Do not pull by the cord.
5. Maintenance
Regular inspection and basic maintenance will ensure the longevity and safe operation of your Hubbell 8460A receptacle.
- Periodic Inspection: Annually inspect the receptacle for any signs of damage, discoloration, loose connections, or excessive heat.
- Cleaning: Disconnect power before cleaning. Use a dry, soft cloth to wipe the surface of the receptacle. Do not use liquid cleaners or solvents.
- Tighten Connections: If accessible and with power disconnected, periodically check and tighten terminal screws to ensure secure electrical contact.
6. Troubleshooting
If you encounter issues with your Hubbell 8460A receptacle, refer to the following troubleshooting guide. Always disconnect power before inspecting or attempting repairs.
| Problem | Possible Cause | Solution |
|---|---|---|
| No power at receptacle |
|
|
| Receptacle feels warm |
|
|
If troubleshooting steps do not resolve the issue, contact a qualified electrician.
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Hubbell |
| Model Number | 8460A |
| Amperage | 60 Amps |
| Voltage | 250 Volts |
| NEMA Configuration | 15-60R |
| Item Weight | 11.2 ounces |
| Product Dimensions | 4 x 4 x 6 inches |
| Compatible Devices | All (compatible 15-60P plugs) |
| Part Number | 8460A |
| UPC | 094701266094 |
8. Warranty and Support
Hubbell products are manufactured to high standards. For specific warranty information or technical support, please refer to the official Hubbell website or contact their customer service department. Always use genuine OEM parts for safety, reliability, and performance.
For further assistance, visit the Hubbell Store on Amazon.