Introduction
Welcome to your APC Back-UPS Pro 1500VA 230V Power Saving Uninterruptible Power Supply. This manual provides essential information for the safe and efficient operation of your UPS, designed to protect your electronic equipment from power outages, surges, and fluctuations. Please read this manual thoroughly before installation and use.
Safety Precautions
- Electrical Shock Hazard: This UPS contains hazardous voltages. Do not attempt to disassemble the unit. Servicing should only be performed by qualified personnel.
- Proper Grounding: Always connect the UPS to a grounded outlet. Do not remove the grounding prong from the power cord.
- Indoor Use Only: This product is intended for indoor use only. Do not install the UPS in direct sunlight, near heat sources, or in areas with excessive moisture.
- Ventilation: Ensure adequate airflow around the UPS. Do not block ventilation openings.
- Battery Safety: Batteries can present a risk of electrical shock and high short-circuit current. Observe all precautions when replacing batteries. Use only APC-approved replacement batteries (RBC154).
- Overload Protection: Do not overload the UPS. Ensure the total power draw of connected equipment does not exceed the UPS's capacity.
Package Contents
Verify that all items listed below are included in your package:
- APC Back-UPS Pro 1500VA 230V UPS Unit
- User Manual (this document)
- Power Cord
- USB Communication Cable
Product Overview
The APC Back-UPS Pro 1500VA 230V is a tower form factor UPS providing reliable battery backup and surge protection for your critical electronic equipment.
Front Panel Features

Front view of the APC Back-UPS Pro 1500VA unit, showing the LCD display and control buttons.
- LCD Display: Provides real-time status information including input/output voltage, load level, battery charge, and estimated runtime.
- Power Button: Turns the UPS unit on or off.
- Display Button: Cycles through various display screens to show different operational parameters.
- Mute/Setup Button: Mutes audible alarms or enters setup mode for configuration.
- USB-A and USB-C Charging Ports: Conveniently located for charging mobile devices.
Rear Panel Features

Rear view of the APC Back-UPS Pro 1500VA unit, showing the power outlets, data ports, and main power input.
- Battery Backup & Surge Protected Outlets: Provide power from the battery during outages and protect against surges. Connect critical equipment here.
- Surge Only Outlets: Provide surge protection only. Connect non-critical equipment here.
- Main Power Input: Connects the UPS to the wall outlet.
- Circuit Breaker: Provides overload protection for the UPS. Press to reset if tripped.
- USB Communication Port: Connects the UPS to a computer for power management software.
- Ethernet/Network Protection Ports: Protects network connections from surges.
Setup
- Unpack and Inspect: Carefully unpack the UPS and all accessories. Inspect for any shipping damage.
- Connect Internal Battery: The UPS battery may be disconnected for shipping. Refer to the battery compartment access panel (usually at the bottom or rear) and connect the battery terminals as indicated.
- Position the UPS: Place the UPS in a location with adequate ventilation, away from direct sunlight, excessive heat, or moisture. Ensure the front and rear vents are unobstructed.
- Connect to Wall Outlet: Plug the UPS power cord directly into a grounded 230V wall outlet. Avoid using extension cords or surge protectors with the UPS input.
- Initial Charge: Allow the UPS to charge for at least 24 hours before connecting any equipment to ensure maximum battery runtime. The battery indicator on the LCD will show charging status.
- Connect Equipment:
- Plug critical equipment (e.g., computer, monitor, router) into the Battery Backup & Surge Protected outlets.
- Plug non-critical equipment (e.g., printer, scanner) into the Surge Only outlets.
- Connect Data Lines (Optional): Connect your USB communication cable from the UPS to your computer to enable power management software features. Connect network cables to the Ethernet protection ports if desired.
Operating Instructions
Turning On/Off
- To Turn On: Press and hold the Power button on the front panel until you hear a beep and the LCD display illuminates.
- To Turn Off: Press and hold the Power button until the LCD display turns off.
LCD Display Navigation
- Press the Display button repeatedly to cycle through various information screens, including: Input Voltage, Output Voltage, Load in Watts, Load in VA, Battery Charge Percentage, and Estimated Runtime.
Alarm Management
- During a power outage, the UPS will emit an audible alarm. Press the Mute/Setup button briefly to temporarily silence the alarm.
- To permanently disable or enable alarms, refer to the detailed instructions in the full user manual or power management software.
Maintenance
Battery Replacement
- The typical battery life is 3-5 years, depending on usage and environmental conditions.
- When the battery needs replacement, the UPS will indicate this on the LCD display and may emit an alarm.
- Use only genuine APC replacement battery cartridges (RBC154) to ensure optimal performance and safety. Refer to the full user manual for detailed battery replacement instructions.
Cleaning
- Regularly clean the exterior of the UPS with a dry cloth.
- Ensure ventilation openings are free from dust and debris to prevent overheating.
Storage
- If storing the UPS for an extended period, ensure the battery is fully charged.
- Store the unit in a cool, dry location with adequate ventilation.
- Recharge the battery every 3-6 months to prevent permanent damage.
Troubleshooting
Below are common issues and their potential solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS will not turn on | Battery disconnected or low charge; UPS not plugged in. | Ensure battery is connected. Plug UPS into a live wall outlet and allow to charge. |
| Short battery runtime | Overloaded; battery old or not fully charged. | Reduce connected load. Allow battery to charge for 24 hours. Replace battery if old. |
| UPS emits continuous alarm | On battery mode; overload; battery fault. | Check power source. Reduce load. Check battery status on LCD. |
| No power to outlets | UPS off; circuit breaker tripped; battery fault. | Turn UPS on. Reset circuit breaker. Check battery status. |
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | BR1500GI |
| Product Dimensions | 4.41 x 15.04 x 11.89 inches |
| Item Weight | 27.9 pounds |
| Voltage | 230 Volts |
| Batteries | 1 12V batteries required (included) |
| Battery Cell Composition | Lead Acid |
| Color | Black |
| Material | Metal |
| Form Factor | Tower |
Warranty and Support
For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric website or contact their customer service department. Keep your purchase receipt as proof of purchase for any warranty claims.
You can find additional resources and contact information at the APC by Schneider Electric Store on Amazon.