1. Introduction
The SINOTIMER STVP series automatic over-voltage and under-voltage protector is designed for three-phase 3*127V/220VAC power systems with a rated working current of 80A. This device provides essential protection for electrical equipment by instantaneously cutting off the power supply when over-voltage, under-voltage, or over-current conditions are detected. Once the circuit voltage returns to normal, the protector automatically restores power, ensuring continuous operation and safeguarding your appliances from damage.
This protector integrates multiple protection functions including over-voltage, under-voltage, over-current, three-phase current (voltage) imbalance, phase sequence (reverse phase), zero-break, and phase-break protection. It also features voltmeter and ammeter functions, and the ability to restore factory settings. The device offers comprehensive features, stable performance, and ease of operation.
A detailed user manual in PDF format is available for download: User Manual (PDF)
2. Key Features
- Over-voltage protection
- Under-voltage protection
- Over-current protection
- Automatic recovery
- Voltage display (separate ABC phase voltage measurement)
- Ampere display (separate ABC phase ampere measurement)
- Three-phase ampere unbalance protection
- Phase sequence protection (reverse phase protection)
- Zero line break protection
- Phase failure protection
- Fault inquiry function
- Rotation display of voltage and current for each phase
- Adjustable over-voltage protection value and recovery value
- Adjustable under-voltage protection value and recovery value
- Adjustable over-current protection value and action time
- Adjustable 3-phase ampere unbalance protection value and action time
- Adjustable delay time after power-on
- Adjustable fault recovery delay time
- Factory data reset function
3. Product Specifications
| Attribute | Value |
|---|---|
| Model Number | STVP936-1-80A |
| Power Supply | 3*127V/220VAC 60Hz |
| Rated Voltage | 220V |
| Phase | Three phase |
| Max. Load Current | 1~80A Adjustable (default: 80A) |
| Over-voltage Protection Range | 121V-150V-OFF Adjustable (default: 140V) |
| Over-voltage Recovery Range | 120V-149V (default: 135V) |
| Over-voltage Action Time | 0.1~10 seconds (default: 0.2s) |
| Under-voltage Protection Range | 118V-80V-OFF Adjustable (default: 90V) |
| Under-voltage Recovery Range | 118V-91V (default: 95V) |
| Under-voltage Action Time | 0.1~10 seconds (default: 0.2s) |
| 3-Phase Volt Unbalance Protection | 10%~50%~OFF (default: 20%) |
| 3-Phase Volt Unbalance Action Time | 0.1~10 seconds (default: 1s) |
| Delay Time After Power-on | 2~255 seconds (default: 2s) |
| Fault Recovery Delay Time | 2~600 seconds (default: 60s) |
| Display Model | LCD |
| Dimensions | 71.5mm (W) * 95.2mm (H) * 65.7mm (D) |
| Installation | 35mm DIN Rail |
| Certification | CE, RoHS |
4. Safety Information
- Installation and maintenance should only be performed by qualified electricians.
- Ensure the power supply is disconnected before any installation or wiring work.
- The device does not provide overload or short-circuit protection. It must be used in conjunction with appropriate external circuit breakers (e.g., C45, C65 mini circuit breakers) for comprehensive protection.
- Verify all wiring connections are secure and correct before applying power.
- Do not operate the device in wet or hazardous environments.
5. Installation
5.1 Physical Dimensions

5.2 Mounting
The protector is designed for 35mm DIN rail installation. Snap the device onto the DIN rail securely.

5.3 Wiring Diagram
Connect the input and output terminals as shown in the diagram below. Ensure correct phase (L1, L2, L3) and neutral (N) connections. The input terminals are located at the top, and output terminals at the bottom.


6. Setup and Configuration
To enter the setting mode, press and hold the SET button for 3 seconds. Then, continuously press SET to cycle through the parameters. Use the ▲ and ▼ buttons to adjust the values. When "ENd" appears, press SET again to save the data and exit the setting mode.
If no operation is performed within 10 seconds after pressing SET, the device will automatically exit the setting mode, and any unsaved changes will be lost.
6.1 Parameter Settings Table
| Step | Content | LCD Display | Description / Range (Default) |
|---|---|---|---|
| 1 | Over-voltage protection value | Uvo 280V | 221V-300V-OFF (280V) |
| 2 | Over-voltage recovery value | Uvor 250V | 220V-299V (250V) |
| 3 | Over-voltage protection action time | 0.2S | 0.1-10s (0.2s) |
| 4 | Under-voltage protection value | Uve 160V | 219V-150V-OFF (160V) |
| 5 | Under-voltage recovery value | Uver 180V | 151V-220V (180V) |
| 6 | Under-voltage protection action time | 0.2S | 0.1-10s (0.2s) |
| 7 | Over-current protection value | >In 80A | 1-80A (80A) |
| 8 | Over-current protection action time | 5S | 1-512s (5s) |
| 9 | 3 phases amp unbalance protection value | >In % | 5%-90%-OFF (25%). Not active if current < 2A. |
| 10 | 3 phases amp unbalance protection action time | 1.0 S | 0.1-10s (1s) |
| 11 | Phase sequence protection | ON ABC | ON or OFF (ON) |
| 12 | Power on delay time | 2 S | 2-255s (2s) |
| 13 | Fault recovery delay time | 60 S | 2-512s (60s) |
| 14 | Fault inquiry code | E0 | Press ▲ to view last 5 fault records (E1-E5). >U for overvoltage, <U for undervoltage. |
| 15 | Ending | ENd | Press SET to save and exit. |
6.2 Factory Reset
To reset the device to factory settings, press and hold the ▲ and ▼ buttons simultaneously for 3 seconds.
7. Operation
Once installed and configured, the device will continuously monitor the three-phase power supply. The LCD screen will automatically rotate to display the real-time voltage and current for each phase (L1, L2, L3).
In case of an over-voltage, under-voltage, or over-current event, the protector will automatically trip and cut off the power supply to protect connected equipment. After the fault condition clears and the recovery delay time has passed, the device will automatically restore power.
8. Troubleshooting
8.1 Fault Inquiry
If a fault occurs, the device will display an error code (E0). You can press the ▲ button to query the last 5 fault records (E1-E5). The display will indicate:
- ">U" for overvoltage events.
- "<U" for undervoltage events.
8.2 Phase Sequence Error
If the LCD displays "ABC" character, it indicates a phase sequence error. To correct this, arbitrarily reverse any two of the three phase lines (L1, L2, L3) at the input.
9. Maintenance
- Keep the device clean and free from dust and moisture.
- Regularly check wiring connections for tightness and signs of wear or damage.
- Do not attempt to repair the device yourself. Refer to qualified personnel for service.
10. Warranty and Support
For technical support, inquiries, or warranty claims, please contact the distributor:
Distributor: XNY INTERNATIONAL LIMITED
Address: Room 20A, Kiu Fu Commercial Building, 300 Lockhart Road, Wanchai, Hong Kong.
Tel: 0086 57761733853
Fax: 0086 577 89736991
WhatsApp: 0086 1565857 3377
Wechat: sinotimer
Skype: sinotimer
Web: www.sinotimer.com