SVP series SINOTIMER brand automatic over-voltage and under-voltage protector is suitable for single-phase AC 230V, 50/60Hz, rated working.
Press '△' to set the fault reset mode to “HA”, “HA” means manual reset.When “HA” is set, the protector will not automatically supply power when powered on ...
SVP-916 Intelligent over-voltage limit current protector instruction manual (double LED digital) SVP series SINOTIMER brand automatic over-voltage and under-voltage protector is suitable for single-phase AC 230V, 50/60Hz, rated working current 63A or less loads.It is mainly used for residential household box entry or over-voltage,under-voltage or over-current protection of distribution lines for single-phase electrical equipment.Its main feature is when the circuit has over-voltage or under-voltage, over-current problems,the product can cut off the power supply instantaneously to protect the electrical equipment from being damaged,besides,the protector can automatically turn on the power supply when the circuit voltage returns to the normal. Features: 1.Over-voltage protection 2.Under-voltage protection 3.Over-current protection 4.Voltage display (voltage measurement) 5.Current display (current measurement) 6.Over-voltage protection value adjustable 7.Over-voltage recovery value adjustable 8.Over-voltage protection action time adjustable 9.Under-voltage protection value adjustable 10.Under-voltage recovery value adjustable 11.Under-voltage protection action time adjustable 12.Over-current protection value adjustable 13.Over-current protection action time adjustable 14.Fault recovery delay time adjustable 15.Delay time after power-on adjustable 16.Reset mode selection 17.Fault inquiry 18.Factory data reset Parameter: Rated voltage Rated current Over-voltage protection value range Over-voltage recovery value range Over-voltage protection action time Under-voltage protection value range Under-voltage recovery value range Under-voltage protection action time Over-current adjustment range Over-current action range Failure recovery delay time Delay time after power-on Power consumption Electrical mechanical life Dimensions Installation Working environment 230VAC 50/60Hz 1-40A Adjustabledefault 40A 1-63A Adjustabledefault 63A 1-80A Adjustabledefault 80A 221V-300V-OFF Adjustabledefault 280V 220V-299V (default 250V) 0.1-10 second default 0.1s 219V-150V-OFF Adjustable default 160V 151V-220V (default 180V) 0.1-10 second default 0.1s 1-40Adefault 40A/ 1-63Adefault 63A/1-80Adefault 80A 0.1 -512 seconddefault 5.0s 2-512 second (default 60s 2-255 second (default 2s) 2W 4000 times 81*36*60mm DIN rail Temperature: -25C+40C Humidity:90% Altitude2000 m Setting method: Press "SET" for 3 seconds, please press continuously "SET" to adjust the required parameter value as follows, or to adjust the set value. Only "END" appears, press "SET" again, the data will be saved and valid. Step 1 2 3 4 5 6 7 8 Content Over-voltage protection value Over-voltage recovery value Upper LED display P01 P02 Lower LED display 280 250 Description Range:221V-300V-OFFdefault 280V Range:220V-299Vdefault 250V Over-voltage protection action time P03 0.1 Range:0.1-10 second default 0.1s Suggest 0.1s Under-voltage protection value P04 Under-voltage recovery value P05 Under-voltage protection action time P06 Over-current protection value P07 Over-current protection P08 160 Range:219V-150V-OFFdefault 160V 180 Range:151V-220Vdefault 180V Range:0.1-10 seconddefault 0.1sSuggest0.3s AttentionAfter the under-voltage action time is set longer than 0.3 s, the relay 0.1 cannot be driven due to the power fault of the MCU. Therefore, when the setting time is longer than 0.3s, the grid cannot be disconnected when the power is cut off. 63 1-40default 40A/ Range:1-63default 63A/ Range:1-80default 80A 5.0 Range:0.1512 seconddefault 5.0s action time 9 Fault recovery delay time P09 10 Power on delay time P10 11 Reset mode selection P11 12 Fault inquiry code P12 13 Ending P13 60 2 AU 1UL END Recommend to set depending on usage Range:2512 seconddefault 60s Range:2255 seconddefault 2s "AU" means the default fault reset mode is auto reset. Press `' to set the fault reset mode to "HA", "HA" means manual reset.When "HA" is set, the protector will not automatically supply power when powered on.So it is necessary to manually press "SET" to turn on the power supply. The protector will not restore the power supply,when the line voltage has "faulty opening", even if the fault is removed, Unless manually pressing the "Set" button on the protector. "1UL" means that the latest fault is an under-voltage fault, "UL"means under-voltage, "UH"means over-voltage, and "IH" means over-current. For example, "1IH" indicates that the last fault is an over-current fault. Press "" to query the last 5 faults This setting is complete. Press"SET"again, the protector saves the data, exits the setting state and enters the running state. The above digital LED displays the working voltage value, and the lower d displays the working current value . Remark: 1.Voltage indicator: The voltage indicator flashes quickly in case of over-voltage, slowly in case of under-voltage, and it is constantly on in case of normal voltage. 2.Current indicator: The current indicator flashes in case of over-current, and it is constantly on when current is normal. 3.Sign of warranty period :During the warranty period, the voltage indicator and the current indicator are constantly on. After the warranty period, they are off under the normal conditions. Only when the voltage exception or the over-current occurs, they will flash. 4.After pressing "SET", if there is no operation within 10 seconds, the device status will be automatically exited, and the changed parameters will not be saved. 5.Press "" and "" together for 3 seconds, and the LED below will be off for 1 second, indicating that the default parameter value of restoring factory settings is completed.WPS 文字