1. Introduction
The ANENG CM82 is a battery-powered, true-RMS, auto-ranging digital clamp multimeter featuring a 6000-count LCD display with backlight. It is designed for precise measurements in various electrical applications.
2. Safety Information
To avoid possible electrical shock, fire, or personal injury, please read all safety information before using this product.
- Do NOT exceed the "maximum value" indicated in the Specifications section.
- Examine the connection of the test leads and the insulation of the product before measuring voltage higher than 36V DC or 25V AC.
- Disconnect the test leads from the circuit before changing the measurement mode.
- Misuse of mode or range can lead to hazards. Be cautious. "OL" will be shown on the display when the input is out of range.
- Do NOT input voltage in Current, Resistance, Diode, Continuity, or Temperature modes.
- Do NOT use the product when the batteries or the battery cover is not placed properly.
- Turn off the product and remove the test leads from the test points before changing batteries.
3. Package Contents
The ANENG CM82 Digital Clamp Meter package typically includes the following items:
- 1 x ANENG CM82 Digital Clamp Multimeter
- 2 x Test Leads (Red and Black)
- 1 x Temperature Sensing Cable (Thermocouple)
- 1 x User Manual (PDF available for download: User Manual PDF)
- 1 x Storage Bag
- 1 x Lanyard
- 1 x Packing Box (depending on the chosen option)

4. Setup
4.1 Battery Installation
The ANENG CM82 requires two AAA batteries (AAA*2) for operation. Follow these steps to install the batteries:
- Locate the battery compartment on the back of the clamp meter.
- Use a screwdriver to loosen the screw on the battery cover.
- Remove the battery cover.
- Insert two AAA batteries, ensuring correct polarity (+ and -).
- Replace the battery cover and fasten the screw.
4.2 Test Lead Connection
For most measurements, test leads are required. Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
5. Product Overview
5.1 Front Panel and Controls

- Jaw: Used for non-contact current measurement.
- Flashlight: Provides illumination in dark environments.
- Jaw Trigger: Opens the clamp meter jaws.
- HOLD / Flashlight Button: Press once to hold the current reading (display shows "HOLD"). Long press to turn the flashlight on/off.
- Dial: Rotary switch to select the desired measurement function (gear). Turn to OFF for power off.
- SEL/NCV Button: Long press for more than two seconds to enter NCV (Non-Contact Voltage) measurement mode. Short press to switch between continuity/diode, capacitance, temperature, AC/DC, and other measurements within a selected gear.
- INR/PEAK Button: Press to enter INRUSH test in current measurement mode. Press to hold voltage reading (PEAK HOLD) in voltage measurement mode.
- HZ/REL Button: In AC mode, press to start frequency measurement. In capacitance and current mode, long press to enter relative value measurement (REL).
- LCD Display: Shows measurement readings, units, and function indicators.
- COM Terminal: Common terminal for all measurements (black test lead).
- VΩHz Terminal: Input port for voltage, frequency, resistance, continuity, diode, and capacitance measurements (red test lead).
- Wire to be measured: The conductor placed within the clamp jaws for current measurement.
5.2 Key Features
- HD Backlit Display: Long press the side button to turn on the backlight for clear readings.
- Flashlight Function: Aids in lighting dark work environments.
- 600A High Current: Capable of measuring up to 600A AC/DC current with a 26mm/1.02in clamp opening.
- Portable Lanyard: Can be attached to the hand for secure handling.
- Automatic Shut-down: Automatically powers off after 15 minutes of inactivity to save power.
- 10A Test Lead Line: Durable stainless steel test leads for plug-and-measure convenience.
- Low Impedance Voltage (LowZ): Avoids measurement errors caused by stray or spurious voltages.
- AC/DC Inrush Current: Measures the surge current during motor or appliance startup.
- NCV Non-Contact Sensing: Safely detects AC voltage without direct contact.
- True RMS: Provides accurate readings for non-sinusoidal waveforms.

6. Operating Instructions
6.1 AC/DC Voltage Measurement
The ANENG CM82 features dual impedance voltage detection. The "V" gear uses a 10MΩ high input impedance for general AC and DC voltage detection. The "V LowZ" gear uses a 600KΩ low input impedance, which helps avoid measurement errors from stray or false voltages, ensuring accurate voltage detection.
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the desired AC (V~) or DC (V-) voltage gear.
- Use the SEL button to switch between AC and DC voltage measurement if needed.
- Touch the probes to the correct test points of the circuit to measure the voltage.
- Read the measured voltage on the LCD display.

6.2 AC/DC Current Measurement
The clamp meter allows for non-contact measurement of AC and DC current.
- Ensure the test leads are not inserted into the jacks.
- Turn the dial to the current gear (A~ for AC, A- for DC).
- Push the jaw trigger to open the clamp jaws.
- Center the single wire within the clamp jaws. For accurate readings, only measure a single-strand wire (zero line or fire line). Common electrical appliance power lines containing multiple core wires cannot be measured accurately.
- Read the measured current on the display.

6.3 Inrush Current Measurement (AC/DC Surge Current)
This function measures the surge current when an appliance or motor starts up.
- Turn the dial to the current gear (A~ for AC, A- for DC).
- Press the "INR/PEAK" button to enter the inrush current measurement mode. The display will show "INRUSH".
- Push the jaw trigger and clamp the single-strand wire of the appliance.
- Start the appliance (e.g., air conditioner, car engine). The instrument will capture the current at the moment of startup.
- Read the measured inrush current on the display.


6.4 Resistance Measurement
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the resistance (Ω) gear.
- Touch the probes to the desired test points of the circuit to measure the resistance.
- Read the measured resistance on the display.
Caution: Disconnect circuit power and discharge all capacitors before testing resistance.
6.5 Diode Measurement
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the diode (→|) gear.
- Press SEL once to enter diode measurement mode.
- Connect the red probe to the anode side and the black probe to the cathode side of the diode to be tested.
- Read the forward biased voltage value on the display. If the polarity is reversed or the diode is broken, the display will show "OL".
6.6 Continuity Measurement
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the continuity (Ω) gear.
- Press SEL again to enter continuity measurement mode.
- Touch the probes to the desired test points of the circuit.
- The built-in beeper will sound if the resistance is lower than 50Ω, indicating continuity.
6.7 Capacitance Measurement
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the capacitance (F) gear.
- Connect the red probe to the positive side and the black probe to the negative side of the capacitor to be tested.
- Read the measured capacitance value on the display.
Caution: Discharge all capacitors before testing capacitance to avoid high voltage hazards.
6.8 Frequency Measurement (Hz)
- Connect the black test lead to the COM terminal and the red test lead to the VΩHz terminal.
- Turn the dial to the Hz gear.
- For AC current frequency, clamp the wire and the meter will display the frequency.
- For AC voltage frequency, touch the probes to the desired test points of the circuit.
- Read the measured frequency value on the display.
6.9 NCV (Non-Contact Voltage) Measurement
- Long press the SEL/NCV button for over 2 seconds to toggle to the NCV mode.
- Hold the product and move it near a potential AC voltage source.
- The built-in beeper will sound, and the screen will display "----" when AC voltage is detected. The stronger the voltage, the quicker the beeper sounds.
- To judge Live (L-line) or Neutral (N-line): Insert the red probe into the VΩHz terminal, then use the black probe to touch the Live line and Neutral line of the main supply. If you hear strong beeps, it's the L-line; otherwise, it's the N-line.

6.10 Temperature Measurement
- Connect the black thermocouple probe to the COM terminal and the red thermocouple probe to the VΩHz terminal.
- Turn the dial to the temperature (°C/°F) test gear. The screen will display the normal ambient temperature by default.
- Touch the probes to the object whose temperature you wish to measure.
- Read the measured temperature on the display.
Caution: Do NOT input voltage in Temperature Mode.
6.11 Peak Hold
- Turn the dial to the voltage measuring gear.
- Insert the test leads.
- Press the "INR/PEAK" button once to activate the peak hold function. The display will show "PEAK HOLD".
- Contact the correct test point on the circuit with the test leads.
- The meter will hold the peak voltage reading.
6.12 Automatic Shut-down
- The product automatically powers off after 15 minutes of inactivity.
- The built-in beeper will sound 5 times one minute before power off.
- To restart the product, press any button.
- To disable the Auto Power Off function, hold down the SEL/NCV button when turning on the product. You will hear the buzzer sound four times, and the "APO" symbol in the upper left corner of the screen will disappear, indicating that the automatic shutdown has been canceled.
7. User Tips
- The ANENG CM82 is categorized as an electrical DIY supply, making it suitable for a wide range of home and professional electrical tasks.
- Users appreciate its ability to accurately measure voltage and current, along with its compact and lightweight design, which enhances portability and ease of use.
8. Maintenance
Beyond replacing batteries, do not attempt to repair or service the product unless you are qualified and have the relevant instructions.
- Do not operate the product around hot, wet, flammable, explosive, or magnetic environments.
- Clean the product with a damp cloth and mild detergent; do not use abrasives or solvents.
- Remove the input signals before cleaning the product.
- Remove the batteries if you will not use the product for a long time to prevent possible battery leakage.
- When the low battery indicator is shown on the display, replace the batteries as described in Section 4.1.
9. Troubleshooting
If your product does not function as normal, the following steps may help. If the problem persists, please contact customer support.
| Problem | Possible Reason | Solution |
|---|---|---|
| Display Malfunction | Low battery | Replace batteries |
| Product not operating properly | Lack of electrical knowledge, improper use, or artificial damage | Contact ANENG customer service with a detailed video of the issue for assistance. |
10. Specifications
| Feature | Range | Resolution | Accuracy | MAX. Value | Frequency Response |
|---|---|---|---|---|---|
| DC Voltage | 6.000V | 0.001V | ±(0.5%+3) | 600V | - |
| 60.00V | 0.01V | - | |||
| 600.0V | 0.1V | - | |||
| AC Voltage | 6.000V | 0.001V | ±(1.0%+3) | 600V | 40Hz-1kHz |
| 60.00V | 0.01V | ||||
| 600.0V | 0.1V | ||||
| DC Current | 60.00A | 0.01A | ±(2.0%+30) | 600A | - |
| 600.0A | 0.1A | - | |||
| AC Current | 60.00A | 0.01A | ±(2.0%+30) | 600A | 40Hz-400Hz |
| 600.0A | 0.1A | ||||
| Resistance | 600.0Ω/6.000kΩ | 0.1Ω/0.001kΩ | ±(1.5%+3) | 60MΩ | - |
| 60.00kΩ/600.0kΩ/6.000MΩ | 0.01kΩ/0.1kΩ/0.001MΩ | ±(0.5%+3) | - | ||
| 60.00MΩ | 0.01MΩ | ±(1.5%+3) | - | ||
| Capacitance | 6.000nF | 0.001nF | ±(5.0%+20) | 60.00mF | - |
| 60.00nF/600.0nF/6.000μF/60.00μF/600.0μF | 0.01nF/0.1nF/0.001μF/0.01μF/0.1μF | ±(2.0%+5) | - | ||
| 6.000mF/60.00mF | 0.001mF/0.01mF | ±(5.0%+5) | - | ||
| Frequency | 60.00Hz/600.0Hz/6.000kHz | 0.01Hz/0.1Hz/0.001kHz | ±(0.1%+2) | 300.0kHz | - |
| 60.00kHz/300.0kHz | 0.01kHz/0.1kHz | ||||
| Temperature | (-30~1000)°C / (-22~1832)°F | 1°C / 1°F | ±(2.5%+5) | 1000°C / 1832°F | - |
| Diode | √ | - | - | - | - |
| Continuity | √ | - | - | - | - |
| Inrush Current | √ | - | - | - | - |
| Peak Hold | √ | - | - | - | - |
| Flashlight | √ | - | - | - | - |
| Data Retention | √ | - | - | - | - |
| Automatic Shut-down | √ | - | - | - | - |
| Low Battery Indication | √ | - | - | - | - |
| Display Type | Analog and Digital | ||||
| Max Count | 6000 counts | ||||
| Weight | 165g | ||||
| Dimensions | 185*65*30mm | ||||
| Material | ABS | ||||
| Battery Type | 1.5V AAA*2 | ||||
| Certification | CE | ||||

11. Warranty and Support
11.1 Limited Warranty
Customers enjoy a one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
11.2 After-Sales Support
If you have any problems during the use of the product, please contact ANENG customer service. Our customer service will provide you with satisfactory solutions in a timely manner.
- About quality issues: In case of quality problems other than "man-made damage" during the use of the product, replacement services or refunds can be provided. For specific product damage, please contact ANENG customer service to confirm and discuss solutions.
- Replacement method: a) Replacement of spare parts, b) Replacement of the whole machine.
- Refund method: a) Partial refund according to damaged parts, b) Full refund if the whole machine is damaged.
- About the product not operating properly: If there is any problem during the use of the product that is not operating normally, please provide a detailed video of the product not operating normally to ANENG customer service. Our experts and technicians can quickly find out the product problem and provide you with a solution.
- Questions about product use: This brand product is a technical product and requires a certain degree of electrical knowledge. If you encounter operational problems or do not understand how to use the product, please contact ANENG customer service in time, we will provide you with assistance.
- About the product has been artificially damaged: This brand is mostly used to detect electrical and other measurement products. It requires a certain degree of electrical knowledge. Pay attention to the use of certain operating procedures, select the correct measurement method, and avoid dangerous events. If the customer uses the product improperly and the use method is not equal, resulting in damage to the product, it will be judged as man-made damage, which is not within the scope of after-sales service of the product. However, you can contact ANENG customer service to receive a certain amount of coupons to deduct the newly purchased ANENG products.

12. Additional Resources
For more detailed information and diagrams, please refer to the official user manual PDF: ANENG CM82 User Manual (PDF).