InBio Pro Plus Series Access Control System

Specifications:

  • Product Name: InBio Pro Plus Series
  • Version: 1.0
  • Battery Type: Valve regulated lead-acid battery
  • Battery Capacity: 12V, 7.2Ah/20hr
  • Initial Current: Less than 2.88A

Product Usage Instructions:

1. Cautions:

  • Do not energize the system before installation is
    complete.
  • All peripheral devices must be grounded.
  • Ensure correct matching of conduits for wires under relay.
  • Avoid exposing connection cables excessively.

2. Normal Working State:

Connect the system to the power supply. The POWER indicator
(red) should be constantly lit, and the RUN indicator (green)
should flash to indicate proper operation.

3. Product Dimensions:

Refer to the dimensions provided for InBio160 Pro Plus, InBio260
Pro Plus, and InBio460 Pro Plus for accurate installation.

4. Installation of Metal Enclosure on the Wall:

  1. Drill three mounting holes in the wall as per the metal
    enclosure’s position.
  2. Place anchors in the mounting holes.
  3. Secure the metal enclosure using self-tapping screws.

5. LED Indicators, Wires, Auxiliary Input and Output:

  1. LED Indicators:
    • RUN indicator (green): Flashing indicates normal system
      operation.
    • CARD indicator (yellow): Flashing indicates a card is punched
      on the reader.
  2. Recommended Use of Wires:
    • Use appropriate cords for power, wiegand reader, lock power,
      and switch power.
    • Refer to the manual for specific wire requirements based on the
      interface connected.

FAQ:

Q: Can I charge the battery in a gas-tight container?

A: No, do not charge the battery in a gas-tight container.

Q: What should I do if I accidentally come into contact with
the battery electrolyte?

A: Flush with water immediately if contact is made with
electrolyte (Acid).

“`

Quick Start Guide
InBio Pro Plus Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.

1. Cautions
Please note the following cautions. Mis-operation may lead to any injury or equipment failure:
1. Do not energize the system before installation is complete; never carry out installation activities when the system is energized.
2. All peripheral devices must be grounded. 3. The conduits of wires under relay must be matched with metaled conduits, other wires can use PVC conduits. 4. It is strongly recommended that the length of the exposed part of any connection cable should not be longer
than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed wires to avoid short-circuit or communication failure. 5. It is recommended that the card readers and the buttons should be installed at a height of 1.4m-1.5m above ground. 6. It is recommended to use the power supply for the control panel, and external power supply for each lock. 7. The appliance shall be installed and wired in accordance with the national electrical code and by qualified personnel only.

Description of normal working state:
Connect the system to the power supply. If the system works properly, the POWER indicator (red) is lit constantly and the RUN indicator (green) flashes.

Valve regulated lead-acid battery:

Constant voltage charge voltage regulation Cycle use: 14.5V to 14.9V(25)

Standby use: 13.6V to 13.8V(25)

Capacity: 12V, 7.2Ah/20hr

Initial current: less than 2.88A Battery Type: LC-RA127R2T1

Cautions:
Do not charge in a gas tight container Do not attempt to disassemble the battery

Do not short the battery terminals

Do not incinerate

Flush with water at once if contact is made with electrolyte (Acid).

1

2. Product Dimension

InBio160 Pro Plus

InBio260 Pro Plus

InBio460 Pro Plus

SWITCH

SWITCH

OUT

SWITCH

SGND
7.29in (185.1mm)
PWR ACT

PC RS485

EXT RS485

STATE

PWR
7.29in (185.1mm)

PC RS485

EXT RS485

STATE

PWR
8.90in (226.0mm)

EXT RS485

PC RS485

STATE

READER1

READER2

4.17in (106.0mm)

4.17in (106.0mm)

4.17in (106.0mm)

1.42in (36.0mm)

1.42in (36.0mm)

1.42in (36.0mm)

1.42in (36.0mm)

1.42in (36.0mm)

1.42in (36.0mm)

2

LED Status Indicator

Metal Enclosure

Cable Conduit (Punch Hole for cables)

POWER RUN COMM

Advanced Access Control
Lock

Heat Dissipation Grill

Metal Enclosure Mounting Holes
DIN Rail Mounting Holes
Metal Enclosure Mounting Holes

3.543in (90.0mm) Tamper Switch
11.811in(300.0mm)
13.780in (350.0mm) 3

3. Installation of Metal Enclosure on the wall
1. According to the mounting holes position of the metal enclosure. Drill three mounting holes in a suitable spot on the wall and make sure it is about 114 inches (2.9m) above the ground, which can be adjusted according to actual needs.Take care to leave at least 3.937 inches (100 mm) on the left side of the metal enclosure.
2. Place the Anchors in the mounting holes. 3. Then f ix the metal enclosure with the self-tapping screws as shown below.
Percussion Drill 1
Anchor 2
Screw 3

Height 114″(2.9m)
(adjustable)

Finished

Note: The metal enclosure is equipped with an tamper alarm switch. When it is working normally, please keep the enclosure closed.

4

4. LED indicators, Wires, Auxiliary Input and Output

1) Understanding the LED indicators:
LINK indicator (green): Always (green) indicates TCP/IP communication is proper. ACT indicator (yellow): Flashing indicates data is in transmitting through TCP/IP communication. TX indicator (yellow): Flashing indicates it is sending data through RS485 communication. RX indicator (green): Flashing indicates it is receiving data through RS485 communication. Auxiliary output indicator (green): Always (green) indicates it is in use. Lock indicator (green): Always (green) indicates lock is open. POWER indicator (red): Always (red) indicates control panel power is on.

RUN indicator (green): Flashing indicates the system works normally. CARD indicator (yellow): Flashing indicates card is punched on reader.
2) Recommended use of wires:
Use 2-conducotor power cord
Use 6-conductor wire between wiegand reader and control panel (RVVP 6*0.5mm) (Choose the appropriate cord for the interface you connect, such as 6, 8, 10 cord.) Use 4-conducotor lock power cord (RVV 4*0.75mm) Use 4-conducotor lock power cord (RVV 4*0.75mm) Use 2-conducotor switch power cord (RVV 2*0.5mm)
3) The auxiliary input may be connnected to infrared body detectors, alam switches, etc.
4) The auxiliary output may be connected to door bells, alarms, etc.

InBio160 Pro Plus

SD Card Slot Function: Backup Access Control Logs

Ethernet interface
DIP switch
PC RS485 interface (Customization) Auxiliary output
Lock & Door sensor Lock power
Control panel power

OUT

SWITCH

PC RS485

EXT RS485

READER1

STATE

Auxiliary input Extended RS485
PWR
Status indicator
ACT
Exit button
Door wiegand reader 1
Door wiegand reader 2

READER2

5

InBio260 Pro Plus

InBio460 Pro Plus

SD Card Slot Function: Backup Access Control Logs

SD Card Slot Function: Backup Access Control Logs

Ethernet interface

DIP switch

PC RS485

interface

(Customization)

SGND

Auxiliary (1-2)output

Lock & Door (1-2)sensor
Lock power Control panel
power

SWITCH

PC RS485

EXT RS485

STATE

Auxiliary input (1-2) Extended RS485
PWR
Status indicator Exit button 1 Door wiegand reader 1
Door wiegand reader 2 Exit button 2 Door wiegand reader 3
Door wiegand reader 4

Ethernet DIP switche
PC RS485 interface (Customization) Auxiliary output
(1-4)
Lock & Door sensor
(1-4)

Lock power Control panel
power

SWITCH

PC RS485

EXT RS485

STATE

Auxiliary input (1-4)
Extended RS485
PWR
Exit button 1 Door wiegand Reader 1 Exit button 2 Door wiegand Reader 2 Exit button 3 Door wiegand Reader 3 Exit button 4 Door wiegand Reader 4

6

PWR
Electric Lock Electric Lock Electric Lock

5. Controller System Installation

Exit Button
Touch No
EXIT

ProID 102

Aux. Input

Wiegand

PC

STATE

TCP/IP TCP/IP
TCP/IP
KF1200 Pro

EXT RS485

PC RS485

SWITCH

Aux. Ouput

OSDP

GND 485485+

Door Sensor

inBio Pro Plus Series

OSDP
Door Sensor

Door Sensor

RS485

#1 EX0808

DC12V

#2 EX0808

DC12V

I/O Expansion Board

#8 EX0808

DC12V

QR500

FR1500S ProID103

ProID102 KF1100 Pro

KF1200 Pro

7

6. Power Connection
Without Backup Battery

PWR

STATE

EXT RS485

PC RS485

SWITCH

With Backup Battery

PWR

STATE

EXT RS485

PC RS485

SWITCH

24V AC

24V AC

POWER

GND

12V

AC

NL +

BT+ BT-

Ground

Switching Power Supply

POWER

GND

12V

AC

+

NL +

BT+ BT-

Ground

Backup Battery Switching Power Supply

8

7. Ethernet Connection
Establish the connection between the device and the software using an Ethernet cable. An illustrative example is provided below:
Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0

IP address: 192.168.1.130 Subnet mask: 255.255.255.0

SWITCH

STATE

SWITCH

PWR

PWR

STATE

EXT RS485

EXT RS485

PC RS485

PC RS485

TCP/IP

TCP/IP

Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to the software.

8. Wiegand Connection

PWR
+12V GND WD0 WD1 GLED BEEP

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

16 or 18 AWG shielded cable recommended

ProID 102

DC+(6-14V) GND Wiegand D0 Wiegand D1 Green LED Beeper

9

READER1

GND IN

9. Auxiliary Input Connection

PWR

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

+12V DC

AUX

GND 12V DC

Fire Alarm

NO COM NC

10. Auxiliary Output Connection

PWR

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

NO +12V DC
GND

10

AUXOUT Alarm

11. Exit Button Connection

PWR

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

Exit Button

GND Button

GND IN

BUTTON1

485+ 485GND +12V

12. RS485 Connection

PWR

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

Baud Rate: ZK485: 115200 OSDP: 115200
485+ 485GND
+12V DC

+12V DC

+12V DC

EXT +12V DC

#8 QR500

#3 FR1500S #2 KF1200 #1 ProID 103

11

Controller Supported Reader Models:

Reader Model KF1100 Pro/KF1200 Pro FR1200/FR1500S ProID101/102/103/104 QR50/QR500/QR600

485 Unencrypted 485 Encryption OSDP Unencrypted

OSDP Encryption

Remarks:
1. means connectable, means not connectable.
2. The KF1000 Pro series reader supports tamper alarm function in both encryption and unencrypted modes of 485 communication. The ProID100 reader supports the tamper function only in 485 communication encryption mode. When the reader is illegal tampering, it will send a tamper signal to the controller via 485, and the controller will report to the software to form a tamper alarm event. Users can configure the alarm linkage on the software side and connect the alarm to the auxiliary output. Encryption is turned on on the software side via the Access >Access Device > Reader > Encrypt path. Please refer to the user manual for more details.

Important Notes:

1. RS485 communication wires should be a shielded twistedpair cable. RS485communication wires shouldbe connectedin a bus cascade topology instead of a star topology, toachievea better shielding effect by reducing signal reflection during communications.
2. A single RS485 bus can connect up to 63 access control panels, but preferably 32 is recommended maximum.
3. To eliminate signal attenuation in communication cables and suppress interference, if the bus is longer than200 meters, set the number 8 DIP switch to the ON position. The number 8 DIP switch is for setting the RS485termination resistance.This is equivalent to a parallel connection of one 120ohm resistance between the 485+ and 485- lines.

ON 123456 78 SINGLE InBio Pro Plus

Distance: More than 200 meters 12

ON 12345678 MULTI InBio Pro Plus

13. Connecting EX0808 via PC485

PWR
485+ 485GND

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

TCP/IP

PC OSDP

GND 485485+

+12V DC
#1 EX0808

+12V DC
#2 EX0808

+12V DC
#8 EX0808

Important Notes:
1. Configure the ZK485 protocol through the PC485 port to connect up to eight EX0808 expansion boards to expand a certain number of auxiliary inputs and auxiliary outputs. Note: Set DIP switch #5 of the expansion board to the OFF position.
2. Configure the OSDP protocol through the PC485 port to connect up to eight EX0808 expansion boards to expand a certain number of auxiliary inputs and auxiliary outputs. Note: Set DIP switch #5 of the expansion board to the ON position.
3. The RS485/OSDP address of each EX0808 is set via the DIP switch before power is applied. 4. Each EX0808 requires a separate power supply. Up to eight auxiliary input devices and eight auxiliary
output devices can be connected to one EX0808. Note: PC485 communication function is a customized function, not standard, please contact yourdealerif you
need it.

13

DIP Switch Setting for RS485/OSDP Communication

D e scri pti on

ARdSd4r8e5ss

DIP Switch

ARdSd4r8e5ss DIP Switch

ARdSd4r8e5ss DIP Switch

1

6

11

K

O

E

2

N1 2 3 4 5 6

7

12

124 8

3

MODE (RS485/OSDP)
4 RS485 Terminal
Resistance

8

13

9

14

5

10

15

Important Notes: There are six DIP switches on the EX0808 expansion board and their functions are: 1. Switches 1- 4 are used to set the RS485/OSDP addresses. 2. Switch 5 is for RS485/OSDP mode switching. When set to OFF, RS485 mode is used, and when set to ON,
OSDP mode is used. 3. If the cable length is more than 200 meters, the switch 6 should be ON for noise reduction on long
RS485 cables.
14

PWR
SEN GND NO COM NC

14. Lock Relay Connection
Controller not sharing power with the lock

STATE

EXT RS485

PC RS485

SWITCH
TCP/IP

+12V DC

Door Sensor

TCP/IP

Normally Closed Lock

LOCK1

Sensor Sensor

Lock Power
GND FR107

+12V DC 12V DC
NC

COM

Do not reverse the polarity.

Switching dry and wet modes Important Notes:

Dry Mode supports separate power supply for the lock using an external independent power supply. Wet

Mode supports the lock sharing power with the controller.The factory default jumper setting is dry mode.

Switch between wet and dry mode by following the steps below.

1. Remove the cover from the bottom by pushing the tabs inward as shown at right.

2. Select the appropriate lock relay and locate its jumper on the controller.

3. Remove the jumpers and change the jumper from

to

.

Controller

4. Once this is done you can follow the wiring of the controller sharing power with the lock.

Dry Mode

Wet Mode

NO COM NC SEN GND NO COM NC SEN GND NO COM
5 4 3 2 1 5 4 3 2 1
NO COM NC SEN GND NO COM NC SEN GND NO COM

AUXOUT4

LOCK1

LOCK2

15

AUXOUT4

LOCK1

LOCK2

SEN GND NO COM NC

Controller sharing power with the lock Normally Opened Lock Powered From Lock Terminal:

PWR

STATE

EXT RS485

PC RS485

V+

V-

LOCK

LOCK1

SWITCH
TCP/IP
TCP/IP

+12V DC

+12V DC

GND 12V DC

Normally Opened Lock

12V DC FR107
GND Do not reverse the polarity.

Normally Closed Lock Powered From Lock Terminal:

PWR

STATE

EXT RS485

PC RS485

LOCK

LOCK1

V-

V+

SWITCH
TCP/IP
TCP/IP

+12V DC

+12V DC

GND 12V DC

Normally Closed Lock

GND FR107
12V DC Do not reverse the polarity.

SEN GND NO COM NC

16

15. DIP Switch Setting

PWR

STATE

EXT RS485

PC RS485

ON 123456 78

SWITCH
1 2 4 8 16 32
RS485 Terminal Resistance

1. Number 1-6 are reserved to set the device number for RS485 communication. The code is binary, and the numbering starts from left to right. When the switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (OFF ).
2. For example, to set a device number 39=1+2+4+32, which corresponds to the binary code 111001, put number 1, 2, 3, and 6 to ON position, as illustrated below.

ON
123456 78 000000

ON
123456 78 111001

17

16. Restore Factory Setting

PWR

STATE

EXT RS485

PC RS485

SWITCH

ON 123456 78
Restore Factory Setting

1. If you forget the IP address of the InBio Pro Plus series panel or the device does not work normally, you can use the number 7 DIP switch to restore it to factory default settings. The parameters which gets reset are device IP address, communication password, gateway, and subnet mask.
2. The switch is OFF by default. When it is moved up and down for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted.
3. The procedure is shown below.

OFF
7
Default Position

ON
7

OFF
7
Final Position

To reset factory settings Turn #7 switch ON and OFF Repeat process 3 times

18

17. Troubleshooting
1. How to switch four door one way to two door two way? Connect four readers from reader 1 to reader 4. Connect two door locks, one connected to LOCK1, another connected to LOCK3. In the software conf igure reader 1-Indoor, and reader 2-Outdoor.
Note: Please note that below option is only available in software version 3.0.3.1 or above. 2. Can we integrate IP Camera and NVR?
Currently ZKBioSecurity software supports ZKVision, GT/PT Series, Hikvision, Dahua, and other cameras supporting Onvif protocol and NVR. You can associate a camera to the reader and setup a linkage for the same. 3. What does it mean when I get a”Wiegand Format Error”? Your WD0 and WD1 wiring is reversed. 4. How do I connect a third party reader or a stand-alone reader to a InBio Pro Plus panel? Connect the wiegand output to the WD0 and WD1 of the stand-alone readers on the panel’s reader port. Note: The board can only supply 12 V DC, 2A power so an external power supply may be required. 5. What kind of wire is recommended for the panel? 16 or 18 AWG twisted shielded wire is recommended. 6. What is the default IP of the panel? 192.168.1.201 7. How long is the device under warranty? 2 Years from original purchase date, replacement/repair of hardware under ZK standard warranty requires an evaluation of the failed system by a ZK Technical Support specialist, and the issuance of a Technical Support RMA number.
19

ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town, Dongguan, China.

Phone : +86 769 – 82109991

Fax

: +86 755 – 89602394

www.zkteco.com

Copyright © 2024 ZKTECO CO., LTD. All Rights Reserved.

Documents / Resources

ZKTECO InBio Pro Plus Series Access Control System [pdf] User Guide
InBio160 Pro Plus, InBio260 Pro Plus, InBio460 Pro Plus, InBio Pro Plus Series Access Control System, InBio Pro Plus Series, Access Control System, Control System

References

Leave a comment

Your email address will not be published. Required fields are marked *