ZEBRONICS-LOGO

ZEBRONICS ZEB-MLS755 Line Interactive UPS System

ZEBRONICS-ZEB-MLS755-Line-Interactive-UPS-System-PRODUCT

INTRODUCTION

Dear Customer,
Thank you for purchasing the ZEB­MLS755 UPS. Please read the user manual carefully before usage & save it for future reference.

Important Safety Instructions

  • The voltages inside UPS may be hazardous. Do not attempt to disassemble the unit. The unit contains no user-serviceable parts. Only factory service personnel may perform repairs.
  • The internal battery voltage is 12Vdc. sealed, lead-acid, battery.
  • Connection to any other type of socket other than a two-pole, three-wire grounded socket may result in shock hazards as well as violation to local electrical codes.
  • In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any external objects to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
  • This unit is designed for installation in a controlled environment (temperature-controlled, indoor area free of conductive contaminants). Avoid installing the UPS in • Do not attach a power strip or surge suppressor to the UPS.
  • Do not connect non-computer-related items, such as medical equipment, life­support equipment, microwave ovens, or vacuum cleaners to UPS.
  • To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as air heaters or furnaces.
  • Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
  • Do not dispose the batteries into fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolytes is harmful to the skin and eyes. It may be toxic.
  • A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
    • a) Remove watches, rings, or other metal objects from the hands.
    • b) Use tools with insulated handles.
    • c) Wear rubber gloves and boots.
    • d) Do not lay tools or metal parts on top of batteries.
  • Servicing of battery should be performed or supervised by technical and authorized personnel only.
  • When replacing battery, replace with the same type of sealed lead-acid battery. The maximum ambient temperature rating is 40°C.

UPS Installation Procedure

  • Your new UPS may be used immediately; however recharging the battery for atleast 8hours (no load) is recommended to ensure that the battery maximum charge capacity is achieved.
  • Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
  • With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  • Press the power switch to turn the unit ON. The power on indicator light will illuminate and the unit will “beep”.
  • If an overload is detected, an audible alarm will sound and the unit will emit beep once every 0.5 seconds. To correct this turn the UPS off and unplug atleast one piece of equipment from the battery power supplied outlets. Wait 10 seconds Make sure the fuse is normal and then turns the UPS on.
  • To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  • To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.

Product Description

ZEBRONICS-ZEB-MLS755-Line-Interactive-UPS-System-FIG-1

Front Panel 

  1. Power Switch
  2. LED Indicators
    AC Mode: Green LED Glow
    Battery Mode: Orange LED blinks
    Fault Mode: Red LED Glow
    Back Panel:
  3. AC input
  4. Output Sockets
  5. Input Fuse

Power On/Off (AC mode)
To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again

Power On/Off (Battery mode)
To start the UPS when AC utility power is

LED Indication and Alarm

Condition Indication Alarm
Normal Green LED Glows  
 

Battery Discharge

 

Orange LED blinks

Beep once

every 10 seconds

 

Battery Low

Red LED Glow and Orange LED flashing Beep once every 1 second
 

Overload

 

Orange LED flashing

Beep once

every 0.5 seconds

Fault Red LED Glow Continuous alarm

Features

  • Line interactive UPS
  • Auto restart while AC is recovering Double Boost
  • Automatic Voltage Regulation (AVR) Wide Input Range

Specifications

Capacity (VA/W) 600VA/360W
 

 

 

Input

Nominal voltage 220-240 VAC
Voltage range 140-300VAC
Frequency 50/60 Hz
Plug type 3 Pin plug
Input Protection Internal Fuse
 

 

 

 

 

Output

Voltage Range (AC mode) 230VAC ± 10 %
Voltage Range (Batt. Mode) 230VAC ± 10 %
Frequency Range (Batt. Mode) 50/60Hz ±1%
Transfer time 4-8ms
Waveform Simulated Sine Wave
No. of output sockets 3
 

Protections

Overload, Short Circuit, Over Discharge &

Over Charge

 

 

Battery

Battery type 12V 7Ahx1 nos
Charging current 1A
Recharge Time 6-8H to charge 90% (after

complete discharge)

 

 

Indicators

No. of LEDs 3 LED
AC mode Green LED Glows
Battery mode Orange LED blinks
Fault mode Red LED Glow
 

 

Alarm

Battery mode Beeping every 1O Secs.
Low battery Beeping every 1 Sec.
Overload Beeping every 0.5 sec.
Fault Continuous beeping
 

 

Physical details

Dimension 10.5 x 27.6 x 14.4 cm (Wx D x H)
Net. weight 3.9 kg
Package dimension 32.6 x 14.2 x 21.3 cm (WxDxH)
Environmental

factors

Operational temperature 0-40°C
Noise level <45dB

Troubleshooting

ZEBRONICS-ZEB-MLS755-Line-Interactive-UPS-System-FIG-2

If any abnormal situations occur that are not listed above, please call service person immediately.

ISO 9001:2015 Certified Company