Zebronics ZEB-MLS755 Uninterruptible Power Supply

User Manual

Introduction

Dear Customer,

Thank you for purchasing the ZEB-MLS755 UPS. Please read the user manual carefully before usage & save it for future reference.

Important Safety Instructions

UPS Installation Procedure

Product Description

Front Panel:

Back Panel:

Power On/Off (AC mode)

To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again.

Power On/Off (Battery mode)

To start the UPS when AC utility power is interrupted, the unit will automatically switch to battery mode.

LED Indication and Alarm

ConditionIndicationAlarm
NormalGreen LED Glows---
Battery DischargeOrange LED blinksBeep once every 10 seconds
Battery LowRed LED Glow and Orange LED flashingBeep once every 1 second
OverloadOrange LED flashingBeep once every 0.5 seconds
FaultRed LED GlowContinuous alarm

Features

Specifications

CategoryDetailsZEB-MLS755
InputNominal voltage220-240 VAC
Voltage range140-300 VAC
Frequency50/60 Hz
Plug type3 Pin plug
Input ProtectionInternal Fuse
OutputVoltage Range (AC mode)230VAC ± 10 %
Voltage Range (Batt. Mode)230VAC ± 10 %
Frequency Range (Batt. Mode)50/60Hz ±1%
Transfer time4-8ms
WaveformSimulated Sine Wave
No. of output sockets3
ProtectionsOverload, Short Circuit, Over Discharge & Over Charge
BatteryBattery type12V 7Ah x 1 nos
Charging current1A
Recharge Time6-8H to charge 90% (after complete discharge)
IndicatorsNo. of LEDs3 LED
AC modeGreen LED Glows
Battery modeOrange LED blinks
AlarmFault modeRed LED Glow
Battery modeBeeping every 10 Secs.
Low batteryBeeping every 1 Sec.
OverloadBeeping every 0.5 sec.
FaultContinuous beeping
Physical detailsDimension (W x D x H)10.5 x 27.6 x 14.4 cm
Net. weight3.9 kg
Package dimension (WxDxH)32.6 x 14.2 x 21.3 cm
Environmental factorsOperational temperature0-40°C
Noise level< 45dB

Troubleshooting

ProblemPossible CauseSolution
No LED Indicator on the front panelBattery weakCharge battery up to 8 hours
Battery defectReplace with the same type of battery
Power switch is not pressedPress the power switch again
Alarm buzzer beeps continuously when AC supply is normalOverload of the UPSVerify that the load matches the UPS capability specified in the specs
Overload of the UPSRemove some non-critical load
When power failure, back-up time is shortenBattery voltage is too lowCharge battery 8 hours or more
Battery defect due to high temperature operation environment, or improper operation to batteryReplace with the same type of battery
Mains normal but Battery Mode indicator orange LED is flashing (for LED model)Power cord is looseReconnect the power cord properly

If any abnormal situations occur that are not listed above, please call service person immediately.

ISO 9001:2015 Certified Company

Visit us at www.zebronics.com

Models: ZEB-MLS755 Line Interactive UPS System, ZEB-MLS755, Line Interactive UPS System, Interactive UPS System, UPS System

PDF preview unavailable. Download the PDF instead.

ZEB-MLS755 UM Corel PDF Engine Version 25.2.0.301 CorelDRAW 2024

Related Documents

Preview Zebronics ZEB-U735 Uninterruptible Power Supply User Manual
User manual for the Zebronics ZEB-U735 Uninterruptible Power Supply (UPS), detailing safety instructions, installation, operation, features, specifications, and troubleshooting for reliable power backup.
Preview Zebronics ZEB-MLS755 Uninterruptible Power Supply - Specifications and Features
Detailed specifications and features of the Zebronics ZEB-MLS755 Uninterruptible Power Supply (UPS), including input/output details, protections, indicators, and physical specifications.
Preview Zebronics ZEB-U725 UPS User Manual: Safety, Installation, Features, and Specifications
Comprehensive user manual for the Zebronics ZEB-U725 Uninterruptible Power Supply (UPS). Provides detailed information on important safety instructions, installation procedures, product features, technical specifications, and troubleshooting.
Preview Zebronics ZEB-MLS750 UPS User Manual - Installation, Features, and Specifications
Comprehensive user manual for the Zebronics ZEB-MLS750 Uninterruptible Power Supply (UPS). Learn about safety instructions, installation, product features, specifications, and troubleshooting for reliable backup power.
Preview Zebronics ZEB-ISPS4CH CCTV Power Supply - Technical Specifications
Explore the technical specifications and features of the Zebronics ZEB-ISPS4CH CCTV Power Supply, including detailed information on input/output voltage, protection mechanisms, operating conditions, and physical dimensions.
Preview Zebronics ZEB-MW61 10000mAh Power Bank User Manual | Features, Specs & Charging
Detailed user manual for the Zebronics ZEB-MW61 10000mAh Power Bank. Learn about its features, specifications, charging instructions, LED indicators, and package contents for optimal use.
Preview Zebronics ZEB-PSS04CH Pro CCTV Power Supply - Specifications and Features
Detailed specifications and features of the Zebronics ZEB-PSS04CH Pro CCTV Power Supply, including input/output voltage, current, protection features, and physical dimensions.
Preview Zebronics Accessories Catalog - Barcode Scanners, Adapters, Power Strips, and More
Explore the comprehensive range of Zebronics computer accessories including barcode scanners, laptop adapters, power strips, multiport adapters, LAN adapters, laptop stands, coolers, USB hubs, WiFi adapters, toner cartridges, and projectors. High-quality electronics for your needs.