YHDC - logo

SCT010T
Ф10mmAperture Split core current transformer

YHDC SCT010T Aperture Split Core Current Transformer -

Characteristic

  • Safety lock buckle, easy to install
  • Built-in over-voltage protection device (TVS tube)
  • Crimping terminal output
  • Suspended type

Product application

  • Portable instrument
  • Household metering
  • Monitor motor load

Product advantage

  • Small volume,Light weight
  • Low cost
  • High turns,High precision

Installation diagram

Primary threading method(Firing line)

  1. Open the buckle
    YHDC SCT010T Aperture Split Core Current Transformer - fig2
  2. Open upward
    YHDC SCT010T Aperture Split Core Current Transformer - fig3
  3. Put in lead wire
    YHDC SCT010T Aperture Split Core Current Transformer - fig1
  4. Fasten the buckle
    YHDC SCT010T Aperture Split Core Current Transformer - fig4

Typical technical index:

  • Material of core——Ferrite
  • Working voltage——Phase voltage≤720V
  • Working temperature——-25℃~+60℃
  • Storage temperature——-30℃~+90℃
  • Frequency range——50Hz~1KHz
  • Dielectric strength——Input(bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz

Electrical parameters:(The following parameters are typical values and actual values will be subject to product testing)
Max. continuous input current: 120% of rated input

Model Input
current
Output Turns ratio Load
resistance
Accuracy Linearity Weight
SCT010T 20A 20mA 1:1000 10Ω 0.5%/1% 1% 45g
SCT010T 20A 5mA 1:4000 10Ω 0.5%/1% 1% 45g
SCT010T 50A 0.1A 0.388889 10Ω 0.5%/1% 1% 45g
SCT010T 50A 50mA 1:1000 10Ω 0.5%/1% 1% 45g
SCT010T 50A 16.6mA 1:3000 10Ω 0.5%/1% 1% 45g
SCT010T 60A 20mA 1:3000 10Ω 0.5%/1% 1% 45g
SCT010T 80A 80mA 1:1000 10Ω 0.5%/1% 1% 45g
SCT010T 80A 40mA 1:2000 10Ω 0.5%/1% 1% 45g
SCT010T 80A 26.6mA 1:3000 10Ω 0.5%/1% 1% 45g
SCT010T 10A 0.333V built-in 0.5%/1% 1% 45g
SCT010T 20A 0.333V built-in 0.5%/1% 1% 45g
SCT010T 30A 0.333V built-in 0.5%/1% 1% 45g
SCT010T 50A 0.333V built-in 0.5%/1% 1% 45g
SCT010T 60A 0.333V built-in 0.5%/1% 1% 45g
SCT010T 80A 0.333V built-in 0.5%/1% 1% 45g

*Can be customized parameters/lead length/lead specifications according to user requirements.

Wiring schematic diagram:

Built-in sampling resistance Voltage output type Secondary doesn’t allow short circuit

YHDC SCT010T Aperture Split Core Current Transformer - fig5TVS:Transient voltage suppressor Current output type Secondary doesn’t allow open circuit

YHDC SCT010T Aperture Split Core Current Transformer - fig6

Outline size: (in:mm):

YHDC SCT010T Aperture Split Core Current Transformer - fig7

www.poweruc.pl

Documents / Resources

YHDC SCT010T Aperture Split Core Current Transformer [pdf] Owner's Manual
SCT010T, SCT010T 50A, SCT010T 60A, SCT010T 80A, SCT010T Aperture Split Core Current Transformer, Aperture Split Core Current Transformer, Split Core Current Transformer, Current Transformer, Transformer