SCT010T
Ф10mmAperture Split core current transformer
Characteristic
- Safety lock buckle, easy to install
- Built-in over-voltage protection device (TVS tube)
- Crimping terminal output
- Suspended type
Product application
- Portable instrument
- Household metering
- Monitor motor load
Product advantage
- Small volume,Light weight
- Low cost
- High turns,High precision
Installation diagram
Primary threading method(Firing line)
- Open the buckle
- Open upward
- Put in lead wire
- Fasten the buckle
Typical technical index:
- Material of core——Ferrite
- Working voltage——Phase voltage≤720V
- Working temperature——-25℃~+60℃
- Storage temperature——-30℃~+90℃
- Frequency range——50Hz~1KHz
- Dielectric strength——Input(bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz
Electrical parameters:(The following parameters are typical values and actual values will be subject to product testing)
Max. continuous input current: 120% of rated input
Model | Input current |
Output | Turns ratio | Load resistance |
Accuracy | Linearity | Weight |
SCT010T | 20A | 20mA | 1:1000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 20A | 5mA | 1:4000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 50A | 0.1A | 0.388889 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 50A | 50mA | 1:1000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 50A | 16.6mA | 1:3000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 60A | 20mA | 1:3000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 80A | 80mA | 1:1000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 80A | 40mA | 1:2000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 80A | 26.6mA | 1:3000 | 10Ω | 0.5%/1% | 1% | 45g |
SCT010T | 10A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
SCT010T | 20A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
SCT010T | 30A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
SCT010T | 50A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
SCT010T | 60A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
SCT010T | 80A | 0.333V | – | built-in | 0.5%/1% | 1% | 45g |
*Can be customized parameters/lead length/lead specifications according to user requirements.
Wiring schematic diagram:
Built-in sampling resistance Voltage output type Secondary doesn’t allow short circuit
TVS:Transient voltage suppressor Current output type Secondary doesn’t allow open circuit
Outline size: (in:mm):