SPECIFICATIONS

Input voltage: 12-24 VAC/DC;
Current consumption: max. 50mA
Sensor type: Infrared
Relay Output: 1A at 24V DC / 120V AC
 

Set relay time:

1, 3, 5, 10, 20, 30, 60 seconds or Toggle (ON/OFF) mode
Detection distance: up to 6 cm
Detection distance

adjustment:

Yes, by DIP switch
Indicators-LED: Green, red, orange
LED control: Yes, internal or external
Tamper: Yes
Backlight ON/OFF: Yes, by DIP switch
Buzzer ON/OFF: Yes, by DIP switch
Operating Temperature: -20o to 50°C
Operating Humidity: Non-condensing up to 95%
Dimensions (mm): 92L x 51W x 27H
Housing ABS
Protection: IP65

MOUNTING

xpr MTT-IR Infrared Touchless Switch fig 1

IMPORTANT NOTE: The touch-free exit button is intended for indoor use. For outdoor use, it must be protected from direct rain / sleet / snow with the MC-MINI protective housing in order to avoid false triggering of the sensor.

TERMINAL BLOCKS AND DIP SWITCH

xpr MTT-IR Infrared Touchless Switch fig 2 xpr MTT-IR Infrared Touchless Switch fig 3

  1. Relay time 1
  2. Relay time 2
  3. Relay time 3
  4. Buzzer ON/OFF
  5. Backlight ON/OFF / LED Control (ON-external, OFF-internal)
  6. Input Level (ON- Low, OFF-high)
  7. Detection distance adjustment (ON-6cm, OFF-2cm)
  8. Not used

WIRING

  • CONNECTION TO ACCESS CONTROL PANELxpr MTT-IR Infrared Touchless Switch fig 4
  • OUTPUT CONNECTION FOR DC DEVICE – FAIL OPENxpr MTT-IR Infrared Touchless Switch fig 5
  • OUTPUT CONNECTION FOR AC DEVICE – FAIL SECURExpr MTT-IR Infrared Touchless Switch fig 6

OPERATION

xpr MTT-IR Infrared Touchless Switch fig 7 xpr MTT-IR Infrared Touchless Switch fig 8 xpr MTT-IR Infrared Touchless Switch fig 9

The device is activated with simple wave of a hand in front of the device.
The device will not be activated if the hand is not removed from the sensor within 3 seconds.

SET RELAY TIME

Relay Time DIP Switch 1 DIP Switch 2 DIP Switch 3
Toggle

(ON/OFF Mode)

OFF OFF OFF
1 Second ON OFF OFF
3 Seconds OFF ON OFF
5 Seconds ON ON OFF
10 Seconds OFF OFF ON
20 Seconds ON OFF ON
30 Seconds OFF ON ON
60 Seconds ON ON ON

xpr MTT-IR Infrared Touchless Switch fig 10

  1. Relay time 1
  2. Relay time 2
  3. Relay time 3
  4. Buzzer ON/OFF
  5. Backlight ON/OFF / LED Control (ON-external, OFF-internal)
  6. Input Level (ON- Low, OFF-high)
  7. Detection distance adjustment (ON-5cm, OFF-2cm)
  8. Not used.

LED CONTROL

xpr MTT-IR Infrared Touchless Switch fig 11 xpr MTT-IR Infrared Touchless Switch fig 12

  1. Input Level (ON- Low, OFF-high)
  2. Backlight ON/OFF / LED Control (ON-external, OFF-internal)

If switch 5 is OFF, then the control of the light is left to the device itself. If switch 5 is ON, then the LED light is controlled by the device where the LED terminals (LG, LR) are connected. Switch 6 defines the default state of the device, where the LED terminals (LG, LR) are connected. Default Low is GND and default high is 12V or open.

xpr MTT-IR Infrared Touchless Switch fig 13Example of externally controlled LED light, where the exit button’s light follows the reader’s light.

This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.

www.xprgroup.com

Documents / Resources

xpr MTT-IR Infrared Touchless Switch [pdf] User Manual
MTT-IR Infrared Touchless Switch, MTT-IR, Infrared Touchless Switch, Touchless Switch, Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *