ZW-O103 Dissolved Oxygen Water Quality Sensor
“
Product Information
Specifications:
- Product Name: Dissolved Oxygen Water Quality Sensor
- Model: ZW-O103
- Manufacturer: Zhengzhou Winsen Electronic Technology Co.,
Ltd - Working Voltage: 5V (DC)
- Power Consumption: Low power consumption
- Detection Temperature: Standard temperature range
- Output Mode: Digital signal output
- Response Time: Fast response time
- Temperature Range: Suitable for various temperature
conditions
Product Usage Instructions:
1. Installation:
Follow the manufacturer’s guidelines to properly install the
ZW-O103 Dissolved Oxygen Water Quality Sensor in the desired
location.
2. Calibration:
Calibrate the sensor according to the provided instructions to
ensure accurate readings.
3. Power Supply:
Connect the sensor to a 5V DC power source for it to function
correctly.
4. Data Output:
Utilize the digital signal output to monitor and analyze the
dissolved oxygen levels in water.
5. Maintenance:
Regularly clean and inspect the sensor to maintain its
performance and longevity.
FAQ:
Q: What is the main application of the ZW-O103 Dissolved Oxygen
Water Quality Sensor?
A: The main application of this sensor is in water quality
testing fields such as aquaculture.
Q: How can I ensure accurate readings from the sensor?
A: Proper calibration following the provided guidelines is
essential to ensure accurate readings from the sensor.
Q: What is the working current of the sensor?
A: The working current specification is not provided in the text
extract. Please refer to the detailed user manual for this
information.
“`
Dissolved Oxygen Water Quality Sensor
ModelZW-O103
Manual
Version1.2 Valid Date2021-12-16
Zhengzhou Winsen Electronic Technology Co., Ltd
Statement
This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can’t spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc, please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users’ comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future.
Zhengzhou Winsen Electronics Technology CO., LTD
ZW-O103 Dissolved oxygen water quality detection module
Profile ZW-O103 dissolved oxygen detection module is a
universal module that uses electrochemical principles to detect oxygen content in water, with good selectivity and stability. Adopting digital signal output, convenient to use. ZW-O103 is a universal gas module designed and manufactured by combining mature electrochemical detection technology with sophisticated circuit design.
Module Features Low power consumption, high precision, linear output, easy calibration, and good stability. Main Application Widely used in water quality testing fields such as aquaculture.
Parameters
Working voltage Module power consumption Detection temperature Output mode Response time Temperature range
5V(DC)
Table 1
Working current
<25mW
Detecting Range
0-40 TTL3V leval
20S 040
Resolution Dimension Size Output linearity
Service life
<5mA
0-20mg/L
0.01mg/L 42X25mm
Linear 3year
Pin Definition: Table 2
PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN11 PIN12
VCC GND VDD RXD3Vleval TXD3Vleval GND Negative terminal Positive terminal
Note: Tolerance range ±0.25mm
Figure 1: Module structure diagram
Sensitivity Curve: Put the module in pure water and oxygen-free water, and the data is as shown in the figure below.
Figure 2: Response and recovery curves
Figure 3: Linear curve
Communication protocols 1. General setting
Baud Rate Data bits Stop bits Check bits
9600 8 bits 1 bit None
2. General commands The default communication mode is active upload mode, with concentration values sent every 1 second or so.
0
1
2
3
4
5
6
7
8
Start bit
Gas name
Unit mg/L
Decimal places
High gas concentration
Low gas concentration
Full range high position
Full range Low position
Checksums
0xFF
0x05
0x11
0x02
0x00
0x05
0x07
0xD0
0x0C
Gas concentration=Gas concentration high byte * 256+Gas concentration low byte
Oxygen concentration=(0 * 256+5) * 0.01=0.05mg/L Full range=Full range * 256+Low range (0x07D0 is 2000, which means the maximum oxygen concentration output from the serial port is 20mg/L)
3. Verification and calculation Verification = (Reverse (Byte 1+Byte 2+…+Byte 7)+1 The reference routine is as follows: /*********************************************************************** *Function nameunsigned char FucCheckSum(unsigned char *i,unsigned char ln) *Function Description: Sum Verification *Function description: Add the elements of an array from 1 to the second to last and take the inverse+1 (the number of elements must be greater than 2) *************************************************************************/ unsigned char FucCheckSum(unsigned char *i,unsigned char ln) { unsigned char j,tempq=0; i+=1; for(j=0;j<(ln-2);j++) { tempq+=*i; i++; } tempq=(~tempq)+1; return(tempq); }
Precautions:
1. Modules should avoid contact with organic solvents, coatings, chemicals, and oils. 2. Do not apply the module to systems involving personal safety. 3. Do not install the module in a strong air convection environment for use. 4. The module should not withstand excessive impact or vibration, and should not produce shaking during use, otherwise the returned values will be inaccurate. 5. Please strictly supply power to the module according to its supply voltage. Voltage exceeding 5.5V can cause irreversible damage to the module. 6. Do not place the module in a strong air convection environment for use. 7. Do not place the mold in high concentration organic gas for a long time.
Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 450001 China Tel: +86-371-67169097/67169670 Fax: +86-371-60932988 E-mail: sales@winsensor.com
Documents / Resources
![]() |
Winson ZW-O103 Dissolved Oxygen Water Quality Sensor [pdf] Instruction Manual ZW-O103 Dissolved Oxygen Water Quality Sensor, ZW-O103, Dissolved Oxygen Water Quality Sensor, Oxygen Water Quality Sensor, Water Quality Sensor, Quality Sensor, Sensor |