MH-Z19C Infrared CO2 Sensor Module
User Manual
Zhengzhou Winsen Electronics Technology Co., Ltd
www.winsen-sensor.com
Statement
This manual’s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in a database or retrieval system, also can’t be spread through electronic, copying, record ways.
Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, or change the components inside of the sensor, we shall not be responsible for the loss.
The specific such as color, appearance, sizes &, etc., please in kind prevail.
We are devoting ourselves to product development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users’ comments on the optimized using way are welcome.
Please keep the manual properly, in order to get help if you have questions during the usage in the future.
MH-Z19C NDIR CO2 Module
Profile
MH-Z19C NDIR infrared gas module is a common type, small size sensor, pins type or terminal type, using non-dispersive infrared (NDIR) principle to detect the existence of CO2 in the air, with good selectivity, non-oxygen dependent and long life. Built-in temperature compensation; and it has UART output and PWM output. It is developed by the tight integration of mature infrared absorbing gas detection technology, precision optical circuit design, and superior circuit design.
Applications
*HVAC refrigeration
*Air cleaner device
*Indoor air quality monitoring
*Smart home
*Ventilation system
*School
Main Features
*Chamber is gold plated
*High sensitivity, low power consumption
*Good stability
*Temperature compensation, excellent linear output
*Multiple output modes: UART, PWM
*Long lifespan
*Anti-water vapor interference, anti-poisoning
Main parameters
Model No. | MH-Z19C |
Detection Gas | CO2 |
Working voltage | 5.0±0.1V DC |
Average current | < 40mA (@5V power supply) |
Peak current | 125mA (@5V power supply) |
Interface level | 3.3 V (Compatible with 5V) |
Detection Range | 400-10000ppm(optional) |
Output signal | Serial Port (UART) (TTL level 3.3V) |
PWM | |
Preheat time | 1 min |
Response Time | T90 < 120 s |
Working temperature | -10 — 50 °C |
Working humidity | 0 — 95% RH (No condensation) |
Storage temperature | -2060 °C |
Weight | 5 g |
Lifespan | > 10 years |
Detection range and accuracy
Detection Gas | Formula | Detection Range | Resolution | Accuracy |
Carbon Dioxide | CO2 | 400-2000ppm | 1PPrn | ± (50ppm+5% reading value) |
400-5000ppm | ||||
400-10000ppm |
Dimensions(Pins type)
Pins connection type:
Pin | Pin Definition |
Vin | The positive pole of power (Vin) |
GND | The negative pole of power (GND) |
PWM | PWM |
Hd | HD(zero point calibration, low level lasting for over 7s is effective) |
Rx | UART(RDX)TTL Level data input |
Tx | UART(TXD)TTL Level data output |
Fig3.from bottom
Dimensions(Terminal type)
Terminal connection type
Pin | Terminal pin Definition |
Pin 4 | Vin power in |
Pin 3 | GND |
Pin 2 | Reserved |
Pin 7 | PWM |
Pin 1 | HD(zero point calibration, low level lasting for over 7s is effective) |
Pin 5 | UART(RDX)TTL Level data input |
Pin 6 | UART(TXD)TTL Level data output |
Fig4.Terminal connection version
Output
PWM output | |
Take 400″2000ppm for example | |
CO2 output range | 400-2000ppm |
Cycle | 1004ms±5% |
Cycle start high-level output | 2ms (theoretical value) |
The middle cycle | 1000ms±5% |
cycle end low-level output | 2ms (theoretical value) |
CO2 concentration: Cppm=2000×(TH-2ms)/(T-4ms) | |
CPPM: CO2 concentration could be calculated by PWM output TH high-level output time during the cycle T output time during the cycle(1004ms±5%) |
Serial port output (UART)
Hardware connection
Connect module’s Vin-GND-RDX-TXD to users’ 5V-GND-TXD-RDX.
(Users must use TTL level. If RS232 level, it must be converted.)
Software setting
Set serial port baud rate be 9600, data bit 8 bytes, stop bit 1byte, parity bit null.
Commands | |
0x86 | Read CO2 concentration |
0x79 | Turn on/off the self-calibration function |
0x86- Read CO2 concentration | ||||||||
Sending command | ||||||||
ByteO | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
Start Byte |
Reserved | Command | – | – | – | – | – | Check m |
OxFF | Ox01 | 0x86 | Ox00 | Ox00 | Ox00 | Ox00 | Ox00 | 0x79 |
Return value | ||||||||
ByteO | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
Start Byte | Command | Concentration (High 8 Byte) | Concentration (Low 8 Byte) |
– | – | – | – | Checksum |
0xFF | 0x86 | HIGH | LOW | – | – | – | – | Checksum |
For example: CO2 concentration = HIGH * 256 + LOW How to calculate concentration: convert hexadecimal 01 into decimal 1, hexadecimal F4 into decimal 244, then 1*256+244=500ppm |
0x79- On/Off Self-calibration for Zero Point | ||||||||
Send command-No return value | ||||||||
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
Start Byte | Reserved | Command | – | – | – | – | – | Checksum |
0xFF | 0x01 | 0x79 | 0xA0/0x00 | 0x00 | 0x00 | 0x00 | 0x00 | Checksum |
No return value NOTE: when byte3 is 0xA0, the auto-calibration function is on; when byte3 is 0x00, the auto-calibration function is turned off. The sensor factory by default is on the self-calibration function. |
Checksum calculation method | ||||||||
Checksum = (Negative (Byte1+Byte2+Byte3+Byte4+Byte5+Byte6+Byte7))+1 | ||||||||
For example: | ||||||||
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
Start Byte | Reserved | Command | – | – | – | – | – | Checksum |
0xFF | 0x01 | 0x86 | 0x00 | 0x00 | 0x00 | 0x00 | 0x00 | Checksum |
Calculating Checksum: 1、Add Byte 1 to Byte 7: 0x01 + 0x86 + 0x00 + 0x00 + 0x00 + 0x00 + 0x00 = 0x87 2、Negative: 0xFF – 0x87 = 0x78 3、Then+1:0x78 + 0x01 = 0x79 |
C language |
char getCheckSum(char *packet) {char i, checksum; for( i = 1; i < 8; i++) { checksum += packet[i]; } checksum = 0xff – checksum; |
Zero Point Calibration
This module has two methods for zero point calibration: the hand-operated method and self-calibration. All the zero point is at 400ppm CO2.
Hand-operated method: |
Connect module’s HD pin to a low level(0V), lasting for 7 seconds at least. Before calibrating the zero point, |
please ensure that the sensor is stable for more than 20 minutes in a 400ppm ambient environment. |
Self-calibration: |
After the module works for some time, it can judge the zero point intelligently and do the zero calibration automatically. The calibration cycle is every 24 hours since the module is powered on. The zero point is 400ppm. This method is suitable for office and home environments, not suitable for agricultural greenhouses, farms, refrigerators, etc.. If the module is used in the latter environment, please turn off this function. |
Notes |
|
Zhengzhou Winsen Electronics Technology Co., Ltd
Add No.299, Jinsuo Road, National Hi-Tech Zone,
Zhengzhou 450001 China
Tel: +86-371-67169097/67169670
Fax: +86-371-60932988
E-mail: sales@winsensor.com
Website: www.winsen-sensor.com
Leading gas sensing solutions supplier in China!
ISO9001 Certificated Company
Issue Date. 2021.05.14